Search icon

TRIPLE B FABRICATING, INC.

Company Details

Name: TRIPLE B FABRICATING, INC.
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Inactive
Date of registration: 21 Nov 1985 (39 years ago)
Date of dissolution: 24 Dec 1997
Entity Number: 1041831
ZIP code: 07481
County: New York
Place of Formation: New Jersey
Address: 373 AUBURN ST., WYCKOFF, NJ, United States, 07481

DOS Process Agent

Name Role Address
JOHN BURRIELLO DOS Process Agent 373 AUBURN ST., WYCKOFF, NJ, United States, 07481

Filings

Filing Number Date Filed Type Effective Date
DP-1359768 1997-12-24 ANNULMENT OF AUTHORITY 1997-12-24
B291373-4 1985-11-21 APPLICATION OF AUTHORITY 1985-11-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339439036 0213100 2013-10-24 SUNY NEW PALTZ WOOSTER SCIENCE BUILDING, NEW PALTZ, NY, 12561
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-10-24
Emphasis L: FALL
Case Closed 2014-09-03

Related Activity

Type Complaint
Activity Nr 856156
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-11-06
Current Penalty 800.0
Initial Penalty 1700.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than one inch wide: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the work deck on the tubular welded framed scaffold system was not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-11-06
Abatement Due Date 2013-11-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the tubular welded framed scaffold system was not erected by a scaffold competent person. Components such as; base plates, coupling pins and adequate planking on the work deck were missing.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-11-06
Abatement Due Date 2013-11-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the employee that was working from the tubular welded framed scaffold system was not trained in the recognition and avoidance of hazards that are involved with these types of scaffold systems.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-11-06
Abatement Due Date 2013-11-13
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the poles on the tubular welded framed scaffold system were not supported on an adequate foundation. Base plates were not installed on the scaffold legs.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2013-11-06
Abatement Due Date 2013-11-13
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the personal fall arrest anchorage point that the iron worker employee was tied off to was not designed to withstand a 5,000 pound load.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260503 C
Issuance Date 2013-11-06
Abatement Due Date 2013-11-13
Current Penalty 700.0
Initial Penalty 1200.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(c): The employer did not retrain affected employees who already had been trained but demonstrated inadequate understanding and skill required by paragraph (a) of this section: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the employer did not retrain iron worker employees in the proper set up of anchorage points for personal fall arrest systems.
Citation ID 02001
Citaton Type Other
Standard Cited 19260452 C03
Issuance Date 2013-11-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-12-05
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: (a) South Elevation, New Elevator Shaft - on or about October 24, 2013 - the vertically stacked frames of the scaffold system were not properly joined together by the use of coupling pins or equivalent means.

Date of last update: 16 Mar 2025

Sources: New York Secretary of State