Search icon

ATLAS METAL WORKING CORP.

Company Details

Name: ATLAS METAL WORKING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 25 Nov 1985 (39 years ago)
Date of dissolution: 09 Jun 2022
Entity Number: 1042582
ZIP code: 12534
County: Columbia
Place of Formation: New York
Address: ROUTE 9, HUDSON, NY, United States, 12534

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent ROUTE 9, HUDSON, NY, United States, 12534

History

Start date End date Type Value
2022-06-09 2022-11-22 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1985-11-25 2022-06-09 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1985-11-25 2022-11-27 Address ROUTE 9, HUDSON, NY, 12534, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
221127000046 2022-06-09 CERTIFICATE OF DISSOLUTION-CANCELLATION 2022-06-09
B292508-6 1985-11-25 CERTIFICATE OF INCORPORATION 1985-11-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339438723 0213100 2013-10-24 4269 RTE 9, HUDSON, NY, 12534
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2013-10-24
Emphasis N: AMPUTATE
Case Closed 2014-02-10

Related Activity

Type Referral
Activity Nr 856470
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100213 L02
Issuance Date 2013-11-04
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2013-11-26
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(l)(2): Boring bits should be provided with a guard that will enclose all portions of the bit and chuck above the material being worked. a) Wood Shop and Assembly Area; On or about 10/24/2013; The three Blum drilling machines were not equipped with guards at the points of operation to prevent employees hands from being caught into the boring bits.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2013-11-04
Current Penalty 680.0
Initial Penalty 1360.0
Final Order 2013-11-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Warehouse Doorway, On or about 10/24/2013; The junction box containing live electrical 120V wires located next to the doorway was not covered, exposing employees to shock and burn hazards.
Citation ID 02001
Citaton Type Other
Standard Cited 19100147 C04 I
Issuance Date 2013-11-04
Abatement Due Date 2013-12-02
Current Penalty 200.0
Initial Penalty 400.0
Final Order 2013-11-26
Nr Instances 3
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Establishment, On or about 10/24/2013; Lockout Procedures were not documented for the ALLSTEEL PRESS CO. Chicago, IL-USA Press Brake: Verson Machine # B-58 / Serial # 7966. b) Establishment, On or about 10/24/2013; Lockout Procedures were not documented for the Dreis & Krump Mfg. Co. Chicago 36, IL Sheet Metal Machinery Press Brake/ Size: 6A8 SP / Serial L-8800. c) Wood Shop, On or about 10/24/2013; Lockout Procedures were not documented for the Wadkin table saw.
339424756 0213100 2013-09-24 4269 RTE 9, HUDSON, NY, 12534
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2013-09-24
Emphasis P: HHHT50, N: CHROME6, L: HHHT50
Case Closed 2014-08-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2014-01-29
Abatement Due Date 2014-03-18
Current Penalty 765.0
Initial Penalty 1440.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees who welded on stainless steel. The employer required the use of N-95 respirators, but had not created a respiratory protection program.
Citation ID 01002
Citaton Type Serious
Standard Cited 19101026 D01
Issuance Date 2014-01-29
Abatement Due Date 2014-05-01
Current Penalty 765.0
Initial Penalty 1800.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees who welded on stainless steel containing hexavalent chromium. The employer had not determined the time-weighted average exposure for these employees.
Citation ID 01003
Citaton Type Serious
Standard Cited 19101052 D02
Issuance Date 2014-01-29
Abatement Due Date 2014-05-01
Current Penalty 765.0
Initial Penalty 1800.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees attaching colored paneling to refridgerators with Premier PB 920 which contained methylene chloride. The employer did not perform initial monitoring to determine these employees' exposure.
Citation ID 01004A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-01-29
Abatement Due Date 2014-03-18
Current Penalty 765.0
Initial Penalty 1080.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees working with hazardous chemicals including but not limited to methylene chloride contained in PB 920, and hexavalent chromium produced when working on 316-type stainless steel. The employer did not have an effective hazard communication program.
Citation ID 01004B
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2014-01-29
Abatement Due Date 2014-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees working with hazardous chemicals including but not limited to methylene chloride contained in PB 920, and hexavalent chromium produced when working on 316-type stainless steel. The employer did not have material safety data sheets available for each chemical in the work area.
Citation ID 01004C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-01-29
Abatement Due Date 2014-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-27
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about 9/24/13 at Atlas Metalworking Corporation, for employees working with hazardous chemicals including but not limited to methylene chloride contained in PB 920, and hexavalent chromium produced when working on 316-type stainless steel. The employer did not train employees on the hazards of these chemicals in the work area.
311974687 0213100 2008-10-17 4269 RTE 9, HUDSON, NY, 12534
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2008-10-17
Emphasis N: AMPUTATE
Case Closed 2008-11-07
310525621 0213100 2008-02-15 4269 RTE 9, HUDSON, NY, 12534
Inspection Type Planned
Scope NoInspection
Safety/Health Health
Close Conference 2008-02-15
Case Closed 2008-02-15
305786444 0213100 2003-01-23 RR 9, HUDSON, NY, 12534
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2003-01-23
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2003-01-24

Related Activity

Type Inspection
Activity Nr 305785685
305785685 0213100 2002-12-05 RR 9, HUDSON, NY, 12534
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2002-12-05
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2003-02-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100213 H01
Issuance Date 2002-12-17
Abatement Due Date 2002-12-20
Current Penalty 560.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19100217 B04 I
Issuance Date 2002-12-17
Abatement Due Date 2002-12-30
Current Penalty 700.0
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 01003
Citaton Type Serious
Standard Cited 19100217 C02 IA
Issuance Date 2002-12-17
Abatement Due Date 2002-12-30
Current Penalty 2000.0
Initial Penalty 2500.0
Nr Instances 3
Nr Exposed 2
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19040007
Issuance Date 2002-12-17
Abatement Due Date 2002-12-20
Nr Instances 1
Nr Exposed 33
Gravity 00
Citation ID 02002
Citaton Type Other
Standard Cited 19100304 F04
Issuance Date 2002-12-17
Abatement Due Date 2002-12-20
Nr Instances 2
Nr Exposed 2
Gravity 01
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 F05 I
Issuance Date 2002-12-17
Abatement Due Date 2002-12-20
Nr Instances 1
Nr Exposed 2
Gravity 01
300529419 0213100 1997-07-25 RR 9, HUDSON, NY, 12534
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 1997-07-25
Emphasis N: PWRPRESS
Case Closed 1997-12-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100110 F04 I
Issuance Date 1997-08-22
Abatement Due Date 1997-10-06
Current Penalty 450.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 1997-08-22
Abatement Due Date 1997-09-24
Current Penalty 450.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 3
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 1997-08-22
Abatement Due Date 1997-10-24
Current Penalty 1125.0
Initial Penalty 2500.0
Nr Instances 2
Nr Exposed 4
Gravity 10
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1997-08-22
Abatement Due Date 1997-10-24
Current Penalty 1125.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 4
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19100217 B04 I
Issuance Date 1997-08-22
Abatement Due Date 1997-10-24
Current Penalty 1125.0
Initial Penalty 2500.0
Nr Instances 4
Nr Exposed 8
Gravity 10
Citation ID 01006
Citaton Type Serious
Standard Cited 19100217 C01 I
Issuance Date 1997-08-22
Abatement Due Date 1997-09-24
Current Penalty 1125.0
Initial Penalty 2500.0
Nr Instances 5
Nr Exposed 8
Gravity 10
Citation ID 01007
Citaton Type Serious
Standard Cited 19100217 E01 I
Issuance Date 1997-08-22
Abatement Due Date 1997-09-24
Current Penalty 450.0
Initial Penalty 1000.0
Nr Instances 5
Nr Exposed 3
Gravity 02
Citation ID 01008
Citaton Type Serious
Standard Cited 19100219 B01
Issuance Date 1997-08-22
Abatement Due Date 1997-11-08
Current Penalty 1125.0
Initial Penalty 2500.0
Nr Instances 3
Nr Exposed 3
Gravity 10
Citation ID 01009
Citaton Type Serious
Standard Cited 19100219 F01
Issuance Date 1997-08-22
Abatement Due Date 1997-11-08
Current Penalty 560.0
Initial Penalty 1250.0
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 02001
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1997-08-22
Abatement Due Date 1997-09-24
Nr Instances 1
Nr Exposed 32
Gravity 00

Date of last update: 27 Feb 2025

Sources: New York Secretary of State