Name: | HARBEC, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 01 Oct 1986 (38 years ago) |
Entity Number: | 1116327 |
ZIP code: | 10528 |
County: | Wayne |
Place of Formation: | New York |
Address: | 600 mamaroneck avenue, #400, HARRISON, NY, United States, 10528 |
Principal Address: | 16340 INNOVATION LANE, FT MYER, FL, United States, 33913 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | HARBEC, INC., CONNECTICUT | 3158904 | CONNECTICUT |
Unique Entity ID | Expiration Date | Physical Address | Mailing Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DG76NQE6DSG3 | 2025-01-08 | 358 TIMOTHY LN, ONTARIO, NY, 14519, 9012, USA | 358 TIMOTHY LN, ONTARIO, NY, 14519, 8958, USA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
URL | https://www.harbec.com/ |
Congressional District | 24 |
State/Country of Incorporation | NY, USA |
Activation Date | 2024-01-09 |
Initial Registration Date | 2010-04-06 |
Entity Start Date | 1978-09-27 |
Fiscal Year End Close Date | Dec 31 |
Service Classifications
NAICS Codes | 326199, 332710, 332999 |
Points of Contacts
Electronic Business | |
---|---|
Title | PRIMARY POC |
Name | JAKE HANLON |
Role | CONTROLLER |
Address | 358 TIMOTHY LANE, ONTARIO, NY, 14519, 8958, USA |
Title | ALTERNATE POC |
Name | KEVIN RALG |
Address | 358 TIMOTHY LANE, WEBSTER, NY, 14580, 8958, USA |
Government Business | |
---|---|
Title | PRIMARY POC |
Name | KEITH SCHNEIDER |
Role | SALES |
Address | 358 TIMOTHY LANE, ONTARIO, NY, 14519, 8958, USA |
Title | ALTERNATE POC |
Name | KEVIN RALG |
Address | 358 TIMOTHY LANE, ONTARIO, NY, 14519, 8958, USA |
Past Performance | Information not Available |
---|
CAGE number | Status | Type | Established | CAGE Update Date | CAGE Expiration | SAM Expiration | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0KH42 | Active | U.S./Canada Manufacturer | 1990-02-07 | 2024-03-10 | 2029-01-09 | 2025-01-08 | |||||||||||||||||||||||||||||||
|
POC | KEITH SCHNEIDER |
Phone | +1 585-265-0010 |
Fax | +1 585-265-1306 |
Address | 358 TIMOTHY LN, ONTARIO, NY, 14519 9012, UNITED STATES |
Ownership of Offeror Information
Highest Level Owner | |
---|---|
Vendor Certified | 2024-01-09 |
CAGE number | 9AED6 |
Company Name | AIPCF VII, LLC |
CAGE Last Updated | 2024-02-29 |
Immediate Level Owner | |
---|---|
Vendor Certified | 2024-01-09 |
CAGE number | 9G7D6 |
Company Name | ADDMAN INTERMEDIATE HOLDINGS LLC |
CAGE Last Updated | 2023-02-13 |
List of Offerors (0) | Information not Available |
---|
Name | Role | Address |
---|---|---|
JOSEPH CALMESE | Chief Executive Officer | 16340 INNOVATION LANE, FT MYER, FL, United States, 33913 |
Name | Role | Address |
---|---|---|
CORPORATE CREATIONS NETWORK INC. | DOS Process Agent | 600 mamaroneck avenue, #400, HARRISON, NY, United States, 10528 |
Start date | End date | Type | Value |
---|---|---|---|
2024-10-04 | 2025-02-24 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2024-10-04 | 2024-10-04 | Address | 16340 INNOVATION LANE, FT MYER, FL, 33913, USA (Type of address: Chief Executive Officer) |
2024-10-04 | 2024-10-04 | Address | 358 TIMOTHY LANE, ONTARIO, NY, 14519, USA (Type of address: Chief Executive Officer) |
2024-10-04 | 2024-10-04 | Address | 9201 COCKLESHELL DR., BONITA SPRINGS, FL, 34135, USA (Type of address: Chief Executive Officer) |
2023-02-23 | 2024-10-04 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-01-12 | 2023-02-23 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-01-12 | 2024-10-04 | Address | 600 mamaroneck avenue, #400, HARRISON, NY, 10528, USA (Type of address: Service of Process) |
2023-01-12 | 2024-10-04 | Address | 9201 COCKLESHELL DR., BONITA SPRINGS, FL, 34135, USA (Type of address: Chief Executive Officer) |
2023-01-12 | 2024-10-04 | Address | 358 TIMOTHY LANE, ONTARIO, NY, 14519, USA (Type of address: Chief Executive Officer) |
2023-01-12 | 2023-01-12 | Address | 9201 COCKLESHELL DR., BONITA SPRINGS, FL, 34135, USA (Type of address: Chief Executive Officer) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
241004001596 | 2024-10-04 | BIENNIAL STATEMENT | 2024-10-04 |
230112001091 | 2023-01-12 | CERTIFICATE OF CHANGE BY ENTITY | 2023-01-12 |
221213000546 | 2022-12-09 | AMENDMENT TO BIENNIAL STATEMENT | 2022-12-09 |
221028003119 | 2022-10-28 | BIENNIAL STATEMENT | 2022-10-01 |
210818001544 | 2021-08-18 | BIENNIAL STATEMENT | 2021-08-18 |
181001006178 | 2018-10-01 | BIENNIAL STATEMENT | 2018-10-01 |
141203007159 | 2014-12-03 | BIENNIAL STATEMENT | 2014-10-01 |
130130002159 | 2013-01-30 | BIENNIAL STATEMENT | 2012-10-01 |
101103002227 | 2010-11-03 | BIENNIAL STATEMENT | 2010-10-01 |
100226000351 | 2010-02-26 | CERTIFICATE OF AMENDMENT | 2010-02-26 |
Contract Type | Award or IDV Flag | PIID | Start Date | Current End Date | Potential End Date | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PURCHASE ORDER | AWARD | N0017311P1671 | 2011-09-08 | 2011-10-06 | 2011-10-06 | |||||||||||||||||||||||||
|
Obligated Amount | 8660.00 |
Current Award Amount | 8660.00 |
Potential Award Amount | 8660.00 |
Description
Title | ROTOR SHAFT |
NAICS Code | 326199: ALL OTHER PLASTICS PRODUCT MANUFACTURING |
Product and Service Codes | 9330: PLASTICS FABRICATED MATERIALS |
Recipient Details
Recipient | HARBEC INC |
UEI | DG76NQE6DSG3 |
Recipient Address | UNITED STATES, 369 RTE 104, ONTARIO, WAYNE, NEW YORK, 145198958 |
Unique Award Key | CONT_AWD_80NSSC24PC367_8000_-NONE-_-NONE- |
Awarding Agency | National Aeronautics and Space Administration |
Link | View Page |
Award Amounts
Obligated Amount | 105768.00 |
Current Award Amount | 105768.00 |
Potential Award Amount | 105768.00 |
Description
Title | 104 END CAPS, 104 END CAP SLEEVES |
NAICS Code | 326199: ALL OTHER PLASTICS PRODUCT MANUFACTURING |
Product and Service Codes | 9905: SIGNS, ADVERTISING DISPLAYS, AND IDENTIFICATION PLATES |
Recipient Details
Recipient | HARBEC INC |
UEI | DG76NQE6DSG3 |
Recipient Address | UNITED STATES, 358 TIMOTHY LN, ONTARIO, WAYNE, NEW YORK, 145199012 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343439469 | 0215800 | 2018-09-04 | 358 TIMOTHY LANE, ONTARIO, NY, 14519 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1375039 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C04 I |
Issuance Date | 2018-11-20 |
Current Penalty | 3180.0 |
Initial Penalty | 4240.0 |
Final Order | 2018-12-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Throughout the facility, on or about 5/14/97: Specific procedures were not developed or written for employees who perform servicing and/or maintenance on various machinery or equipment including but not limited to: Six - Akira Seiki Mills; Seven - Hurco Mills; Three - Kiwa Machines; Four-Mitsubishi Machines; Nakamura-Tome Machine; Five-Perfect Jet Mill and Empire Sand Blaster. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101053 D01 |
Issuance Date | 2018-11-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-12-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1053(d)(1): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section: a) Models Production Area, on or about 9/4/18: Employee runs parts through a sand blaster using Blastite containing silica and initial monitoring for silica was not conducted. |
Inspection Type | FollowUp |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2016-03-09 |
Case Closed | 2016-04-06 |
Related Activity
Type | Inspection |
Activity Nr | 1079215 |
Health | Yes |
Inspection Type | FollowUp |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-03-09 |
Emphasis | N: AMPUTATE |
Case Closed | 2016-04-21 |
Related Activity
Type | Inspection |
Activity Nr | 1078513 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Repeat |
Standard Cited | 19100212 A01 |
Issuance Date | 2016-03-17 |
Current Penalty | 4320.0 |
Initial Penalty | 7200.0 |
Final Order | 2016-04-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Harbec, Inc., on or about 3/09/16: Tree Journeyman 425 milling machine was used without a guard in place to prevent contact with the rotating cutting tool. Harbec Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1) which was contained in OSHA inspection number 1078513, citation number 1, item number 2 and was affirmed as a final order on 09/16/15 with respect to a workplace located at 369 Route 104, Ontario, NY. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2015-09-02 |
Case Closed | 2015-10-28 |
Related Activity
Type | Referral |
Activity Nr | 1002252 |
Health | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100095 B01 |
Issuance Date | 2015-09-09 |
Abatement Due Date | 2015-10-14 |
Current Penalty | 3375.0 |
Initial Penalty | 4500.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized: a) At the recycling room, on or about 7/22/2015: An employee working as the plastic recycling grinder operator was exposed to continuous noise at a sound level of 389.1% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 389.1% is approximately 99.8 dBA calculated as the 8 hour time weighted sound pressure level. Sampling was conducted for 253 minutes. A zero increment was included for the remaining 227 minutes of the workday. No administrative or engineering controls were utilized. Abatement documentation must be submitted for this citation. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100095 C01 |
Issuance Date | 2015-09-09 |
Abatement Due Date | 2015-10-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) At the recycling room, on or about 7/22/2015: The employer did not administer a hearing conservation program for employee(s) at the facility who operated the grinder. Monitoring performed by OSHA showed an employee who operated the grinder was exposed to continuous noise at a level of 389.1% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 389.1% is approximately 99.8 dBA calculated as the 8 hour time weighted sound pressure level. Sampling was conducted for 253 minutes. A zero increment was included for the remaining 227 minutes of the workday. Abatement documentation must be submitted for this citation. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-07-17 |
Emphasis | N: AMPUTATE, P: AMPUTATE |
Case Closed | 2015-10-14 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100157 G02 |
Issuance Date | 2015-09-09 |
Abatement Due Date | 2015-10-14 |
Current Penalty | 2025.0 |
Initial Penalty | 2700.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 165 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Harbec, Inc., on or about 7/17/15: The employer has not provided initial and/or annual training to employees on the use and application of fire extinguishers. * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b). |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2015-09-09 |
Abatement Due Date | 2015-10-14 |
Current Penalty | 2700.0 |
Initial Penalty | 3600.0 |
Final Order | 2015-09-16 |
Nr Instances | 3 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Harbec, Inc., on or about 7/17/15: Dake Johnson horizontal bandsaw was not equipped with an adjustable guard to cover the unused portion of the blade during operation. The unused blade on the right side measured 6 inches and on the left side measured 9 inches. b) Harbec, Inc., on or about 7/17/15: Tree Journeyman 425 milling machine was not equipped with a guard to prevent contact with the serrated chuck and tooling during operation. c) Harbec, Inc., on or about 7/17/15: Cincinnati Gilbert radial drill press, serial number 1079, was not equipped with a guard to prevent contact with the serrated chuck and tooling during operation. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100303 B02 |
Issuance Date | 2015-09-09 |
Abatement Due Date | 2015-10-14 |
Current Penalty | 2700.0 |
Initial Penalty | 3600.0 |
Final Order | 2015-09-16 |
Nr Instances | 2 |
Nr Exposed | 51 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Plastics Secondary Area, North Building, on or about 7/17/15: Pendant cords with metal receptacle boxes attached were used to provide power to various equipment. These metal boxes are listed for permanent mounting only. b) Plastics, South Building, on or about 7/17/15: Pendant cords with metal receptacle boxes attached were used to provide power to various equipment. These metal boxes are listed for permanent mounting only. |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19100134 C02 I |
Issuance Date | 2015-09-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Harbec, Inc. on or about 7/17/15: Employee who was voluntarily wearing an MCR RPDM1 nuisance dust mask while sanding parts had not been provided with the training and information contained in Appendix D to 29 CFR 1910.134. |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19100134 D01 II |
Issuance Date | 2015-09-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-09-16 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: a) Harbec, Inc. on or about 7/17/15: The employer allowed employees to voluntarily wear an MCR nuisance dust mask while sanding parts. This dust mask was not NIOSH certified. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4691198705 | 2021-04-01 | 0219 | PPS | 358 Timothy Ln, Ontario, NY, 14519-9012 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7187647010 | 2020-04-07 | 0219 | PPP | 369 ROUTE 104, ONTARIO, NY, 14519 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1804467 | Intrastate Non-Hazmat | 2021-10-18 | 20000 | 2020 | 1 | 1 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 2 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 2 |
Vehicle Maintenance BASIC Roadside Performance measure value | 4 |
Total Number of Vehicle Inspections for the measurement period | 1 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 1 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 1 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Inspections
Unique report number of the inspection | SPE0340888 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2024-07-26 |
ID that indicates the level of inspection | Walk-around |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 3 |
Number of Out-Of-Service violations related to Driver | 0 |
Number of Out-Of-Service violations related to vehicle | 1 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 1 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | INTL |
License plate of the main unit | 61659NC |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 1HTSCABL21H405926 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 1 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 0 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 1 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Violations
The date of the inspection | 2024-07-26 |
Code of the violation | 3939 |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | Y |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 2 |
The severity weight that is assigned to a violation | 2 |
The time weight that is assigned to a violation | 3 |
The description of a violation | Inoperable Required Lamp |
The description of the violation group | Clearance Identification Lamps/Other |
The unit a violation is cited against | Vehicle main unit |
Date of last update: 27 Feb 2025