Search icon

PINNACLE MANUFACTURING COMPANY, INC.

Company Details

Name: PINNACLE MANUFACTURING COMPANY, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 19 Jan 1988 (37 years ago)
Entity Number: 1227715
ZIP code: 14020
County: Genesee
Place of Formation: New York
Address: 56 Harvester Avenue, #1, Batavia, NY, United States, 14020

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARIN 2017 161317413 2018-10-15 PINNACLE MANUFACTURING COMPANY, INC. 5
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARIN 2016 161317413 2017-08-31 PINNACLE MANUFACTURING COMPANY, INC. 5
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARIN 2015 161317413 2017-08-31 PINNACLE MANUFACTURING COMPANY, INC. 39
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARIN 2014 161317413 2015-10-23 PINNACLE MANUFACTURING COMPANY, INC. 46
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARIN 2013 161317413 2015-10-23 PINNACLE MANUFACTURING COMPANY, INC. 47
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARING PLAN 2012 161317413 2013-09-17 PINNACLE MANUFACTURING COMPANY, INC 45
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020

Signature of

Role Plan administrator
Date 2013-09-17
Name of individual signing KIM KISIEL
Role Employer/plan sponsor
Date 2013-09-17
Name of individual signing KIM KISIEL
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARING PLAN 2011 161317413 2012-07-18 PINNACLE MANUFACTURING COMPANY, INC 42
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020

Plan administrator’s name and address

Administrator’s EIN 161317413
Plan administrator’s name PINNACLE MANUFACTURING COMPANY, INC
Plan administrator’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
Administrator’s telephone number 5853435664

Signature of

Role Plan administrator
Date 2012-07-18
Name of individual signing KIM KISIEL
Role Employer/plan sponsor
Date 2012-07-18
Name of individual signing KIM KISIEL
PINNACLE MANUFACTURING COMPANY, INC. PROFIT SHARING PLAN 2010 161317413 2011-07-14 PINNACLE MANUFACTURING COMPANY, INC 42
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1988-06-01
Business code 332900
Sponsor’s telephone number 5853435664
Plan sponsor’s address 9091 CREEK ROAD, BATAVIA, NY, 14020

Plan administrator’s name and address

Administrator’s EIN 161317413
Plan administrator’s name PINNACLE MANUFACTURING COMPANY, INC
Plan administrator’s address 9091 CREEK ROAD, BATAVIA, NY, 14020
Administrator’s telephone number 5853435664

Signature of

Role Plan administrator
Date 2011-07-14
Name of individual signing KIM KISIEL
Role Employer/plan sponsor
Date 2011-07-14
Name of individual signing KIM KISIEL

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 56 Harvester Avenue, #1, Batavia, NY, United States, 14020

Chief Executive Officer

Name Role Address
DIANA KISIEL KASTENBAUM Chief Executive Officer 56 HARVESTER AVENUE, #1, BATAVIA, NY, United States, 14020

History

Start date End date Type Value
2023-11-28 2023-11-28 Address PO BOX 1446, BATAVIA, NY, 14020, 1446, USA (Type of address: Chief Executive Officer)
2023-11-28 2023-11-28 Address 56 HARVESTER AVENUE, #1, BATAVIA, NY, 14020, 3357, USA (Type of address: Chief Executive Officer)
2014-02-25 2023-11-28 Address PO BOX 1446, BATAVIA, NY, 14020, 1446, USA (Type of address: Chief Executive Officer)
2010-04-30 2023-11-28 Address 56 HARVESTER AVE, BATAVIA, NY, 14020, USA (Type of address: Service of Process)
1993-03-05 2014-02-25 Address 9091 CREEK ROAD, BATAVIA, NY, 14020, USA (Type of address: Principal Executive Office)
1993-03-05 2014-02-25 Address 56 HARVESTER AVE, BATAVIA, NY, 14020, USA (Type of address: Chief Executive Officer)
1993-03-05 2010-04-30 Address 9091 CREEK ROAD, BATAVIA, NY, 14020, USA (Type of address: Service of Process)
1988-01-19 1993-03-05 Address 56 HARVESTER AVENUE, BATAVIA, NY, 14020, USA (Type of address: Service of Process)
1988-01-19 2023-11-28 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
231128000102 2023-11-28 BIENNIAL STATEMENT 2022-01-01
140225002520 2014-02-25 BIENNIAL STATEMENT 2014-01-01
120130002160 2012-01-30 BIENNIAL STATEMENT 2012-01-01
100430002265 2010-04-30 BIENNIAL STATEMENT 2010-01-01
080102002386 2008-01-02 BIENNIAL STATEMENT 2008-01-01
060131002867 2006-01-31 BIENNIAL STATEMENT 2006-01-01
040106002183 2004-01-06 BIENNIAL STATEMENT 2004-01-01
011217002718 2001-12-17 BIENNIAL STATEMENT 2002-01-01
000327002750 2000-03-27 BIENNIAL STATEMENT 2000-01-01
980109002543 1998-01-09 BIENNIAL STATEMENT 1998-01-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340630854 0213600 2015-05-11 56 HARVESTER AVE., BATAVIA, NY, 14020
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-07-17
Case Closed 2016-09-30

Related Activity

Type Complaint
Activity Nr 982112
Safety Yes
Health Yes
Type Inspection
Activity Nr 1068238
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C02 II
Issuance Date 2015-07-28
Abatement Due Date 2015-08-30
Current Penalty 402.0
Initial Penalty 2100.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Facility - On or about 6/4/15, the employer has provided and an employee uses a half-face, elastomeric respirator to perform cleaning of filters. The employer has not established and implemented those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored and maintained so that its use does not present a health hazard to the user. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2015-07-28
Abatement Due Date 2015-08-30
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Facility - On or about 6/4/15, the employer has provided and an employee wears an elastomeric, half face respirator with cartridges for certain cleaning activities. The employer has not provided a medical evaluation to the employee to determine the employee's ability to use a respirator. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2015-07-28
Abatement Due Date 2015-08-30
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) Facility - On or about 6/4/15, the employer has provided and an employee uses an elastomeric, half face respirator for cleaning activities. The employer did not ensure that the employee was trained for the required respiratory protection elements prior to use. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2015-07-28
Abatement Due Date 2015-10-15
Current Penalty 1802.0
Initial Penalty 3500.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Facility - On or about 6/5/15, multi-energy equipment, such as but not limited to, the aluminum (700T, 600T, and 400T) and zinc (125T, 200T) and the Castmaster (electric 480V; 90 PSI; gas and hydraulic energies), did not have equipment-specific procedures developed and documented for the control of potentially hazardous energies when employees were engaged in covered activities, such a maintenance, repair, and die changes. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 II
Issuance Date 2015-07-28
Abatement Due Date 2015-10-15
Current Penalty 1102.0
Initial Penalty 2800.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Facility - On or about 6/5/15, multi-energy equipment, such as but not limited to, the aluminum (700T, 600T, and 400T) and zinc (125T, 200T) and the Castmaster (electric 480V; 90 PSI; gas and hydraulic energies). The employer did not certify that periodic inspections of the energy control procedures had been performed. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2015-07-28
Abatement Due Date 2015-10-15
Current Penalty 1802.0
Initial Penalty 3500.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a.) Facility - On or about 6/15/15, die changers remove and replace dies in the Lesters and Castmasters on an up to daily basis. These employees have not been provided Lockout Tagout training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01005
Citaton Type Other
Standard Cited 19100157 G01
Issuance Date 2015-07-28
Abatement Due Date 2015-08-30
Current Penalty 0.0
Initial Penalty 1785.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 40
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) Facility - On or about 6/4/15, the employer has provided a variety of mounted fire extinguishers throughout the facility for use during an incipient fire. The employer has not provided fire extinguisher training to the employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100178 Q01
Issuance Date 2015-07-28
Current Penalty 1102.0
Initial Penalty 2800.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a.) Facility - On or about 5/11/15, a strap that hold the propane tank onto the Mitsubishi powered industrial truck (PIT), was broken. The PIT was not taken out of service until the repair was made. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100178 Q07
Issuance Date 2015-07-28
Abatement Due Date 2015-08-05
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) Facility - On or about 5/11/14, the Mitsubishi powered industrial truck (PIT) was not inspected prior to use: the latch for one of the straps for the propane tank was missing/broken. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01007A
Citaton Type Serious
Standard Cited 19100184 D
Issuance Date 2015-07-28
Abatement Due Date 2015-08-07
Current Penalty 1102.0
Initial Penalty 2800.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(d): Sling(s) and fastenings were not inspected each day or during use and were not removed from service when damaged or defective: a) Facility - On or about 5/11/15, chains/chain slings and hooks, used to move large dies for manufacturing, were not inspected each day during use and were not removed from service when damaged or defective. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01007B
Citaton Type Serious
Standard Cited 19100184 E03 I
Issuance Date 2015-07-28
Abatement Due Date 2015-08-05
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.184(e)(3)(i): Thorough periodic inspections of alloy steel chain slings in use were not made on a regular basis: a.) Facility - On or about 5/11/15, employee use chains/chain slings to move manufacturing dies throughout the facility. A thorough periodic inspection of steel chain slings in use was not made. Chains were still being used that had deformed from weight/heavy loads. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01008
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2015-07-28
Current Penalty 1802.0
Initial Penalty 3500.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Facility Zinc Room - On or about 5/15/15, a trim press in the Zinc room was not guarded to prevent employees from having any part of their body in the danger zone(s) during operating cycles. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100023 A08 II
Issuance Date 2015-07-28
Abatement Due Date 2015-08-30
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-08-07
Final Order 2015-11-02
Nr Instances 1
Nr Exposed 40
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk were not guarded by a floor hole cover of standard strength and construction: a.) Facility - On or about 6/5/15, floor holes which are less than 12 inches but greater than 1 inch in its least dimension, were not guarded by a floor hole cover of standard strength and construction. ABATEMENT CERTIFICATION REQUIRED
310025309 0213600 2006-07-06 56 HARVESTER AVENUE, BATAVIA, NY, 14020
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2006-08-30
Case Closed 2006-10-26

Related Activity

Type Complaint
Activity Nr 204902134
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C02 II
Issuance Date 2006-09-13
Abatement Due Date 2006-10-16
Current Penalty 700.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2006-09-13
Abatement Due Date 2006-10-16
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2006-09-13
Abatement Due Date 2006-09-25
Nr Instances 1
Nr Exposed 2
Gravity 01
106940521 0213600 1996-11-12 56 HARVESTER AVENUE, BATAVIA, NY, 14020
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 1996-11-12
Case Closed 1996-11-14
107348716 0213600 1993-06-15 56 HARVESTER AVENUE, BATAVIA, NY, 14020
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 1993-06-22
Case Closed 1993-12-30

Related Activity

Type Complaint
Activity Nr 74622135
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100132 A
Issuance Date 1993-08-10
Abatement Due Date 1993-12-23
Current Penalty 1300.0
Initial Penalty 2000.0
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 1993-08-10
Abatement Due Date 1993-09-13
Current Penalty 520.0
Initial Penalty 800.0
Nr Instances 1
Nr Exposed 4
Gravity 02
Citation ID 02001
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1993-08-10
Abatement Due Date 1993-08-27
Nr Instances 1
Nr Exposed 1
Gravity 01
107340150 0213600 1990-01-29 56 HARVESTER AVENUE, BATAVIA, NY, 14020
Inspection Type Prog Other
Scope Complete
Safety/Health Safety
Close Conference 1990-01-29
Case Closed 1990-04-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Current Penalty 250.0
Initial Penalty 420.0
Nr Instances 1
Nr Exposed 2
Gravity 06
Citation ID 01002
Citaton Type Serious
Standard Cited 19100036 B04
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Current Penalty 200.0
Initial Penalty 350.0
Nr Instances 1
Nr Exposed 3
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19100101 B
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Current Penalty 200.0
Initial Penalty 350.0
Nr Instances 2
Nr Exposed 5
Gravity 05
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Current Penalty 200.0
Initial Penalty 350.0
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Nr Instances 1
Nr Exposed 2
Gravity 00
Citation ID 01005
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 1990-02-06
Abatement Due Date 1990-02-23
Current Penalty 200.0
Initial Penalty 300.0
Nr Instances 1
Nr Exposed 2
Gravity 04
Citation ID 02001
Citaton Type Repeat
Standard Cited 19101200 E01
Issuance Date 1990-02-06
Abatement Due Date 1990-03-30
Current Penalty 490.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 15
Gravity 05
Citation ID 02002
Citaton Type Repeat
Standard Cited 19101200 F05 I
Issuance Date 1990-02-06
Abatement Due Date 1990-03-30
Current Penalty 490.0
Initial Penalty 700.0
Nr Instances 10
Nr Exposed 15
Gravity 05
Citation ID 03001
Citaton Type Other
Standard Cited 19100026 C02 VII
Issuance Date 1990-02-06
Abatement Due Date 1990-02-12
Nr Instances 2
Nr Exposed 2
Gravity 00
100523356 0213600 1988-06-29 56 HARVESTER AVENUE, BATAVIA, NY, 14020
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 1988-08-18
Case Closed 1988-08-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100141 G02
Issuance Date 1988-07-28
Abatement Due Date 1988-08-08
Current Penalty 180.0
Initial Penalty 180.0
Nr Instances 3
Nr Exposed 3
Citation ID 01002
Citaton Type Serious
Standard Cited 19100178 L
Issuance Date 1988-07-28
Abatement Due Date 1988-08-31
Current Penalty 180.0
Initial Penalty 180.0
Nr Instances 1
Nr Exposed 3
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 1988-07-28
Abatement Due Date 1988-08-31
Current Penalty 180.0
Initial Penalty 180.0
Nr Instances 1
Nr Exposed 4
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 F04 I
Issuance Date 1988-07-28
Abatement Due Date 1988-08-31
Nr Instances 1
Nr Exposed 4
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 H
Issuance Date 1988-07-28
Abatement Due Date 1988-08-31
Nr Instances 1
Nr Exposed 4
Citation ID 02001
Citaton Type Other
Standard Cited 19030002 A01
Issuance Date 1988-07-28
Abatement Due Date 1988-07-31
Nr Instances 1
Nr Exposed 15

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5712677106 2020-04-13 0296 PPP 56 Harvester Ave, BATAVIA, NY, 14020-3342
Loan Status Date 2021-10-21
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 169900
Loan Approval Amount (current) 169900
Undisbursed Amount 0
Franchise Name -
Lender Location ID 56102
Servicing Lender Name KeyBank National Association
Servicing Lender Address 127 Public Sq, CLEVELAND, OH, 44114-1217
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description Unanswered
Project Address BATAVIA, GENESEE, NY, 14020-3342
Project Congressional District NY-24
Number of Employees 19
NAICS code 331523
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 56102
Originating Lender Name KeyBank National Association
Originating Lender Address CLEVELAND, OH
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 172325.15
Forgiveness Paid Date 2021-10-04
6273198505 2021-03-03 0296 PPS 56 Harvester Ave, Batavia, NY, 14020-3357
Loan Status Date 2022-08-16
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 143600
Loan Approval Amount (current) 143600
Undisbursed Amount 0
Franchise Name -
Lender Location ID 56102
Servicing Lender Name KeyBank National Association
Servicing Lender Address 127 Public Sq, CLEVELAND, OH, 44114-1217
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address Batavia, GENESEE, NY, 14020-3357
Project Congressional District NY-24
Number of Employees 16
NAICS code 331523
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 56102
Originating Lender Name KeyBank National Association
Originating Lender Address CLEVELAND, OH
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 145519.91
Forgiveness Paid Date 2022-07-21

Date of last update: 16 Mar 2025

Sources: New York Secretary of State