346576424
|
0215800
|
2023-03-20
|
18 PHELPS ST, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-20
|
Case Closed |
2023-05-09
|
Related Activity
Type |
Referral |
Activity Nr |
2011544 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2023-04-28 |
Current Penalty |
5859.75 |
Initial Penalty |
7813.0 |
Final Order |
2023-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2):The employer did not report an in-patient hospitalization of one or more employee as a result of a work-related incident to OSHA within twenty-four (24) hours. a) At Binghamton Precast & Supply Corp., on or about 3/1/2023: An employee fell from a ladder, broke his wrist, fractured his pelvis, and was hospitalized. OSHA was not notified of the hospitalization until March 20, 2023. |
|
|
343333191
|
0215800
|
2018-07-26
|
99 WEST ARTERIAL HIGHWAY, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-07-26
|
Case Closed |
2018-08-17
|
Related Activity
Type |
Referral |
Activity Nr |
1360963 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1333430 |
Safety |
Yes |
|
|
341563583
|
0215800
|
2016-06-17
|
18 PHELPS STREET, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-09-13
|
Emphasis |
N: SILICA
|
Case Closed |
2018-09-18
|
Related Activity
Type |
Referral |
Activity Nr |
1101369 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2016-10-27 |
Current Penalty |
3749.0 |
Initial Penalty |
6859.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1) Employer did not establish nor implement a written respiratory protection program with worksite specific procedures when respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: a) Outside Work Areas, on or about 6/17/16: Employer had not established a written respirator protection program when employees were required to wear dust masks and/or half face air purifying respirators. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 C02 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Outside Work Areas, on or about 6/17/16: Employer allowed voluntary use of dust masks and had not supplied employees with Appendix D of the respirator standard. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 D01 II |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: a) Outside Area, Back Pad Area, on or about 9/13/16: The Dry Finisher was exposed to airborne respirable silica at a concentration of .690 mg/m3 time weighted average, 1.68 times the permissible exposure limit (PEL) of .41 mg/m3. The PEL was based on 22% crystalline silica in the sample. The sample was collected on 9/13/16 for 223 minutes. Zero exposure was assumed for the 257 minutes not sampled. Employee was not wearing a one strap dust mask respirator that was not NIOSH approved. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
3749.0 |
Initial Penalty |
6235.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting face piece respirator was fit tested prior to initial use of the respirator, whenever a different respirator face piece (size, style, model or make) was used, and at least annually thereafter: a) Outside Areas, on or about 6/17/16: Employees required to wear half face air purifying respirator and N95 Dust Mask Respirators had not been fit tested. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 G01 I A |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(g)(1)(i)(A): Tight fitting face piece respirators were worn when facial hair came between the sealing surface of the face piece and the face: a) Outside Area, South End, on or about 9/13/16: Employee had facial hair and was required to wear a N95 half mask dust respirator while grinding. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19101000 C |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-12-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1000(c): Employees were exposed to materials in excess of the eight hour permissible exposure limit, listed in Table Z-3 of subpart Z of 29 CFR part 1910: a) Outside Area, South End, on or about 9/13/16, a dry finisher grinding concrete was exposed to 1.25 milligrams per cubic meter (mg/m3) of airborne silica for a eight hour time weighted average (TWA) which was approximately 2.87 times the OSHA permissible exposure limit of .435 mg/m3. The sampling period was for 122 minutes. A zero increment is included for the 358 minutes not sampled. Employee was wearing a N95 Dust Mask Respirator. b) Outside Area, Back Pad Area, on or about 9/13/16, a dry finisher grinding concrete was exposed to .690 milligrams per cubic meter (mg/m3) of airborne silica for a eight hour time weighted average (TWA) which was approximately 1.68 times the OSHA permissible exposure limit of .410 mg/m3. The sampling period was for 223 minutes. A zero increment is included for the 197 minutes not sampled. Employee was wearing a one-strap Dust Mask Respirator. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19101000 E |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-05-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a) Outside Area, South End, on or about 9/13/16: Feasible administrative or engineering controls were not implemented to reduce employee exposure to silica below the OSHA Permissible Exposure Limit. Employee exposures as referenced in Citation 1 Item 3c. b) Outside Area, Back Pad Area, on or about 9/13/16: Feasible administrative or engineering controls were not implemented to reduce employee exposure to silica below the OSHA Permissible Exposure Limit. Employee exposures as referenced in Citation 1 Item 3c. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
3749.0 |
Initial Penalty |
6235.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employees medical evaluations when the employee is no longer required to use a respirator. a) Outside Work Areas, on or about 6/17/16: Employees required to wear half face air purifying respirators and N95 Dust Mask Respirators and had not been provided with a medical evaluation. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-16 |
Current Penalty |
3749.0 |
Initial Penalty |
6236.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k) The employer did not provide effective, comprehensive, understandable, and annual (or more often if necessary) training to employees who are required to use respirators: a) Outside Work Areas, on or about 6/17/16: Employees required to wear half face air purifying respirators and N95 Dust Mask Respirators and had not received respirator training. |
|
|
341461119
|
0215800
|
2016-05-06
|
18 PHELPS STREET, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-06-07
|
Case Closed |
2018-09-19
|
Related Activity
Type |
Referral |
Activity Nr |
1088322 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-08 |
Current Penalty |
4286.0 |
Initial Penalty |
7482.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 A02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-31 |
Current Penalty |
4286.0 |
Initial Penalty |
6236.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: a) On or about 5/6/2016, Mixer Area: Ladderway openings on the first and second level platforms were not provided with swing gates or offsets. Employees exposed to falls of up to 16 feet b) On or about 6/7/2016, Aggregate elevator Area: The ladderway opening at the top of the access ladder was not provided with swing gates or off sets. Employees exposed to falls of 28 feet. Abatement certification is required for these items. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-31 |
Current Penalty |
4286.0 |
Initial Penalty |
6236.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
8 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) On or about 5/6/2016, Mixer Area: A front platform on the mixer had chain guardrails that had six inches of deflection. The top rails were a height of 28 inches and the midrails were at a height of 12 inches. Employees exposed to falls of 10.5 feet. b) On or about 5/6/2016, Mixer Area: A front platform on the mixer was not provided with any midrail. Employees exposed to falls of eight feet. c) On or about 5/6/2016, Mixer Area: A platform on the second level of the mixer had an unguarded platform opening. Employees exposed to falls of eight feet. d) On or about 5/6/2016, Mixer Area: A platform on the second level of the mixer, in the front was not provided with a rail system. Employees were exposed to falls of eight feet. e) On or about 5/6/2016, Inside Form Area: No rails or other fall protection was provided while employees were walking and working on top of forms. Employees exposed to falls of 6.5 feet. f) On or about 6/7/2016, Exterior Form Area: No rails or other fall protection was provided while employees were walking and working on top of the forms. Employees exposed to falls of nine feet. g) On or about 6/7/2016, Platform Above the Turret: The top rails were at a height of 27 inches above the platform and the midrails were at a height of 8 inches above the platform. Employees exposed to falls of 34 feet. h) On or about 6/7/2016, Sand/ Aggregate Bins: No rails or other fall protection was provided while employees were walking and working on top of the bins. Employees exposed to falls of 8 feet. Abatement certification is required for these items. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19100025 D02 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.25(d)(2)(i): Portable ladders were not used so that the ladders feet extended approximately one quarter of the ladders working length: a) On or about 5/6/2016, Mold Area: Wooden shop made ladders were used while their feet extended one half the distance of their working length. Abatement certification is required for these items. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19100025 D02 XIX |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.25(d)(2)(xix): Portable ladders were not equipped with non slip bases: a) On or about 5/6/2016, Mold Area: Wooden shop made ladders were in use without non slip bases while set up on concrete. Abatement certification is required for these items. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100106 E02 IV A |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered container(s) when not actually in use: a) On or about 6/7/2016, Paint Area: Flammable thinners and paints (sealers) such as, but not limited to Xylene, Carboline Bitumastic 300M and Coopers C4 were left in open topped containers. Abatement certification is required for these items. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: a) On or about 6/7/2016, Paint Area: Smoking and open flames from propane torches are allowed where open containers of flammable liquids are present along with freshly applied flammable liquids. Abatement certification is required for these items. |
|
Citation ID |
01005C |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) On or about 6/7/2016, Paint Area: Flammable thinners and paints (sealers) such as, but not limited to Xylene, Carboline Bitumastic 300M and Coopers C4 were transferred without any bonding and grounding between containers. b) On or about 6/7/2016, Back Pod Area: Sil-Act Sealer is transferred without bonding and grounding between containers. Abatement certification is required for these items. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100106 E05 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(5)(i): Portable fire extinguishment and control equipment was not provided in such quantities and types as were needed for special hazards of operation and storage: a) On or about 6/7/2016, Paint Area: There was no fire protection where flammable liquids were in storage and in use. Abatement certification is required for these items. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100106 E09 II |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(9)(ii): Adequate aisles were not maintained for unobstructed movement of personnel and fire protection equipment: a) On or about 6/7/2016, Paint Area: Debris, boxes, wooden pallets, tools, propane cylinders, product, and dunnage obstructed the walking area, working area and aisles. Abatement certification is required for these items. |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19100106 E09 IV |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(9)(iv): Ground areas around buildings and unit operating areas were not kept free of weeds, trash, and/or other unnecessary combustible materials: a) On or about 6/7/2016, Paint Area: Debris, boxes, wooden pallets, tools, propane cylinders, and dunnage were left in the spray area. Abatement certification is required for these items. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100132 D02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
3741.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: a) On or about 5/6/2016, Throughout the facility: No certification was performed to ensure that employees exposed to various hazards throughout the facility were provided with appropriate PPE such as but not limited to appropriate hand protection and respiratory protection. Abatement certification is required for these items. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) On or about 6/7/2016, Paint Area: Impervious gloves such as butyl/ nitrile were not used while applying products such as, but not limited to Sikagard 62, Coopers C4, andTrumbull 60-32 sealers. Abatement certification is required for these items. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100146 C02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
6236.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) On or about 5/6/2016, Throughout the facility: The company did post signs at permit required confined spaces to inform employees of their existence. This includes locations such as, but not limited to the concrete mixer and aggregate bins. Abatement certification is required for these items. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100146 C04 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a) On or about 5/6/2016, Throughout the facility: The company did not implement a confined space entry program. Employees are exposed while entering confined spaces such, but not limited to concrete mixers and aggregate bins. Abatement certification is required for these items. |
|
Citation ID |
01009 |
Citaton Type |
Other |
Standard Cited |
19100169 B03 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
22 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves: a) On or about 5/6/2016, Throughout the facility: Metal containers were in use to hold and dispense form oil. The containers were pressurized with air. There was no relief valve to prevent over pressurization. Abatement certification is required for these items. |
|
Citation ID |
01010A |
Citaton Type |
Serious |
Standard Cited |
19100178 A04 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-08-12 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) On or about 6/7/2016, Concrete Pouring Area: A Caterpillar powered industrial truck was being utilized with a lifting attachment other than what was approved by the manufacturer. Abatement certification is required for these items. |
|
Citation ID |
01010B |
Citaton Type |
Serious |
Standard Cited |
19100178 A05 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a) On or about 6/7/2016, Concrete Pouring Area: A Caterpillar powered industrial truck was being utilized with a lifting attachment other than what was approved by the manufacturer. No additions were added to the trucks data plate. Abatement certification is required for these items. |
|
Citation ID |
01010C |
Citaton Type |
Serious |
Standard Cited |
19100178 O02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-12 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(o)(2): Load(s) were being handled which exceeded the rated capacity of the industrial truck(s): a) On or about 6/7/2016, Concrete Pouring Area: A Caterpillar powered industrial truck was being utilized with a lifting attachment which allowed for the load to exceed the capacity rating of the truck. Abatement certification is required for these items. |
|
Citation ID |
01011 |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a) On or about 6/7/2016, Warehouse area: A Hyster diesel powered industrial truck was in use without an operational horn or operational parking brake. Abatement certification is required for these items. |
|
Citation ID |
01012A |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2016-11-08 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) On or about 6/7/2016, Back Interior Shop Area: A Jet table saw was used without an automatically adjusting hood. Abatement certification is required for these items. |
|
Citation ID |
01012B |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) On or about 6/7/2016, Back Interior Shop Area: A Jet table saw was used without a spreader. Abatement certification is required for these items. |
|
Citation ID |
01012C |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about 6/7/2016, Back Interior Shop Area: A Jet table saw was used without non kick back fingers. Abatement certification is required for these items. |
|
Citation ID |
01013 |
Citaton Type |
Serious |
Standard Cited |
19100253 E03 II |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(e)(3)(ii): Approved protective equipment (designated P(F) in Figures Q1, Q2, and Q3) were not installed in fuel gas piping system, such as, but not limited to anti flow back protection: a) On or about 6/7/2016, Back Pod Area: An oxy acetylene torch was used without a back flow preventer. Abatement certification is required for these items. |
|
Citation ID |
01014A |
Citaton Type |
Serious |
Standard Cited |
19100303 B01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
4988.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) On or about 6/7/2016, Back Interior Shop Area: A blue colored extension cord powering a Styrofoam cutter was damaged. Abatement certification is required for these items. |
|
Citation ID |
01014B |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about 6/7/2016, Back Interior Shop Area: Metal parts of the Styrofoam cutting table were not provided with a continuous path to ground. b) On or about 6/7/2016, Back Interior Shop Area: Styrofoam cutting tools were not provided with a continuous path to ground. Abatement certification is required for these items. |
|
Citation ID |
01015 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
6236.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
2 |
Nr Exposed |
20 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about 5/6/2016, Mixing Area: Employees are exposed to energized electrical parts while inside of a mixer control box. b) On or about 6/7/2016, South Side Shop Area: Employees are exposed to energized electrical parts inside of an electrical box mounted next to the break room door. Abatement certification is required for these items. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
4286.0 |
Initial Penalty |
12471.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 6/7/2016, Back Interior Shop Area: An alligator shear was not properly guarded, the existing guard was not adjusted so that it was effective. b) On or about 6/7/2016, Back Interior Shop Area: A Rebar shear was not adequately guarded, the two hand controls were being operated with one hand. Abatement certification is required for these items. Binghamton Precast & Supply Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(1), which was contained in OSHA inspection number 981961, citation number 1, item number 3 and was affirmed as a final order on 7/23/2014, with respect to a workplace located at 18 Phelps Street, Binghamton, NY. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2016-10-27 |
Current Penalty |
0.0 |
Initial Penalty |
3500.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours: a) On or about 5/6/2016, At the facility: The employer did not report a finger amputation that occurred on 9/22/2015. b) On or about 5/6/2016, At the facility: The employer did not report a finger amputation that occurred on 1/9/2015. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
16 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 6/7/2016, Throughout the facility: The employer had not performed a periodic review of their energy control procedures. Abatement certification is required for these items. |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19100219 C04 I |
Issuance Date |
2016-10-27 |
Abatement Due Date |
2017-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-11-10 |
Final Order |
2017-08-17 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) projected more than one half the diameter of the shaft: a) On or about 6/7/2016, Base of storage tower: A shaft end was not guarded at the base of the access ladder. Abatement certification is required for these items. |
|
|
340991439
|
0215800
|
2015-10-15
|
18 PHELPS STREET, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-15
|
Case Closed |
2016-04-12
|
Related Activity
Type |
Complaint |
Activity Nr |
1029148 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100025 D01 I |
Issuance Date |
2016-03-07 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-03-28 |
Nr Instances |
1 |
Nr Exposed |
15 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.25(d)(1)(i): Portable wood ladder(s) were not maintained in good condition at all times with all hardware and fittings securely attached: a) At the jobsite, on or about 10/15/15: Employees were using shop built ladders that did not have cleats installed, making them unsafe for use. Abatement certification must be submitted for this item. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100026 A03 VIII |
Issuance Date |
2016-03-07 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-28 |
Nr Instances |
1 |
Nr Exposed |
15 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.26(a)(3)(viii): Stepladders did not have a metal spreader or locking device of sufficient size and strength to securely hold the front and the back sections in the open position: a) At the jobsite, on or about 10/15/15: Employees were using a section of a 5 foot step ladder that had been dismantled to use as a straight ladder. Abatement certification must be submitted for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100184 F05 III |
Issuance Date |
2016-03-07 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
1540.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-03-28 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(f)(5)(iii): Wire rope sling(s) that had kinking, crushing, bird caging or other damage resulting in distortion of the wire rope structure were not immediately removed from service: a) At the jobsite, in the production yard area: Operators were moving precast products around the yard with a fork truck and slings, where those slings were damaged, crushed, and displayed bird caging, where those slings had been identified and marked for removal, and where those slings remained in use. Abatement certification must be submitted for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100243 C01 |
Issuance Date |
2016-03-07 |
Abatement Due Date |
2016-03-11 |
Current Penalty |
1540.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-03-28 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s): a) At the jobsite, in the production area, on or about 10/15/15: Employees used hand grinders to finish concrete castings where those grinders did not have guards attached. Abatement certification must be submitted for this item. |
|
|
340044403
|
0215800
|
2014-10-24
|
17 THOMAS STREET, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-10-24
|
Emphasis |
L: BRIDGE, P: BRIDGE
|
Case Closed |
2015-11-17
|
Related Activity
Type |
Referral |
Activity Nr |
917080 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100178 L03 II C |
Issuance Date |
2015-01-12 |
Abatement Due Date |
2015-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
3500.0 |
Contest Date |
2015-01-19 |
Final Order |
2015-06-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(3)(ii)(C): Powered industrial truck operators did not receive initial training on load manipulation, stacking, and un-stacking: a) At the workplace, in the yard, on or about 10/23/14: Employees were loading 4,000 lb. panel-sections of pre-cast concrete onto a drop-bed trailer without having been trained on the hazards associated with unique types of pre-cast product relative to shape and size. Abatement documentation must be submitted for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 L03 II I |
Issuance Date |
2015-01-12 |
Abatement Due Date |
2015-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-01-19 |
Final Order |
2015-06-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(3)(ii)(I): Powered industrial truck operators did not receive initial training in other unique or potentially hazardous conditions of the workplace that could affect safe operation: a) At the workplace, in the yard, on or about 10/23/14: Employees were loading 4,000 lb. panel-sections of pre-cast concrete onto a drop-bed trailer without having been trained on the hazards associated with unique types of pre-cast product relative to shape and size. Abatement documentation must be submitted for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 |
Issuance Date |
2015-01-12 |
Abatement Due Date |
2015-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-01-19 |
Final Order |
2015-06-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4): 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a) At the workplace, in the yard, on or about 10/23/14: Employees were loading 4,000 lb. panel-sections of pre-cast concrete onto a drop-bed trailer without having received re-training within a 3 year period. Abatement documentation must be submitted for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2015-01-12 |
Abatement Due Date |
2015-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
4900.0 |
Contest Date |
2015-01-19 |
Final Order |
2015-06-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Storage was not secure. Storage of material created a hazard. Material stored in tiers were not stacked, blocked, and interlocked so that they are stable and secure against sliding or tipping. a) At the workplace, in the yard, on or about 10/24/14: Employees were loading 4,000 lb. panels of pre-cast concrete onto a drop-bed trailer where the load was able to be released from the control connection without ensuring that it was stable and secure. Abatement documentation must be submitted for this item. Or, in the alternative: OSH Act of 1970 Section 5 (a)(1) of the Occupational Safety and Health Act of 1970; The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard. a) At the workplace, in the yard, on or about 10/24/14: Employees were loading 4,000 lb. panels of pre-cast concrete onto a drop bed trailer where the load was not secure or otherwise prevented from tipping, and where employees following established procedures were exposed to the fall shadow of the loads. Feasible and acceptable methods to correct the hazard include but are not limited to: 1) Modify the base of the "A" frame support so that it meets the slope of the support at a right angle which ensures that the panels are seated correctly on the truck bed. 2) Modify the release procedure and tools to allow the employee to be outside the "fall shadow" of the item being loaded. 3) Follow administrative controls as detailed in the National Precast Concrete Association "Guide to Plant Safety" and "Material Handling Safety in a Precast Plant". |
|
|
339819617
|
0215800
|
2014-06-20
|
18 PHELPS STREET, BINGHAMTON, NY, 13901
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-06-20
|
Emphasis |
N: AMPUTATE, P: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2014-08-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2014-07-22 |
Abatement Due Date |
2014-08-14 |
Current Penalty |
1470.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-07-23 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): Place(s) of employment were not kept clean: a) Fab Shop, on or about 6/20/14: Explosive Wood Dust (Class II) build up was observed all over the floor near the Compound Radial Arm Saw and the Jet Table Saw. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100157 G02 |
Issuance Date |
2014-07-22 |
Abatement Due Date |
2014-08-14 |
Current Penalty |
1470.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-07-23 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Throughout the facility, on or about 6/20/14: Training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39 which includes the evacuation requirements of 29 CFR 1910.157(b). |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-07-22 |
Abatement Due Date |
2014-08-14 |
Current Penalty |
1470.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-07-23 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) Maintenance Shop, on or about 6/20/14: Leland Gifford Drill Press was not provided with a chuck and tool guard. b) Maintenance Shop, on or about 6/20/14: Ellis Band Saw was not protected with a guard on the unused portion of the blade on the right side. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100213 H01 |
Issuance Date |
2014-07-22 |
Abatement Due Date |
2014-08-14 |
Current Penalty |
1470.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-07-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the matetrial being cut: a) Maintenance Shop, on or about 6/20/14: Sears Craftsman Radial Saw had no lower blade guard on either side of blade. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100213 H04 |
Issuance Date |
2014-07-22 |
Abatement Due Date |
2014-08-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-07-23 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a) Maintenance Shop, on or about 6/20/14: Sears Craftsman Radial Arm Saw did not return to the starting position when released. |
|
|
307686063
|
0215800
|
2004-09-15
|
PHELPS STREET, PORT DICKENSON, NY, 13901
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2004-11-01
|
Emphasis |
S: AMPUTATIONS, L: CONCRETE
|
Case Closed |
2004-11-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2004-11-03 |
Abatement Due Date |
2004-12-06 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100217 C01 I |
Issuance Date |
2004-11-03 |
Abatement Due Date |
2004-12-31 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
|
307686048
|
0215800
|
2004-09-15
|
PHELPS STREET, PORT DICKENSON, NY, 13901
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2004-11-01
|
Emphasis |
L: CONCRETE, S: SILICA, N: SILICA
|
Case Closed |
2004-11-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2004-11-03 |
Abatement Due Date |
2004-11-08 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 |
Issuance Date |
2004-11-03 |
Abatement Due Date |
2004-11-08 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
|
106160054
|
0215800
|
1991-11-22
|
PHELPS STREET, PORT DICKENSON, NY, 13901
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1991-11-22
|
Case Closed |
1992-01-27
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C02 I |
Issuance Date |
1991-12-31 |
Abatement Due Date |
1992-02-04 |
Current Penalty |
612.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II |
Issuance Date |
1991-12-31 |
Abatement Due Date |
1992-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
1991-12-31 |
Abatement Due Date |
1992-01-06 |
Current Penalty |
613.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100304 F04 |
Issuance Date |
1991-12-31 |
Abatement Due Date |
1992-01-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|