345407514
|
0213600
|
2021-07-06
|
3550 UNION ROAD, CHEEKTOWAGA, NY, 14225
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-07-06
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2021-11-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260152 G11 |
Issuance Date |
2021-08-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-09-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(g)(11):Each service or refueling area was not provided with at least one fire extinguisher having a rating of not less than 20B:C located so that an extinguisher would be within 75 feet of each pump, dispenser, underground fill pipe opening and lubrication or service center: a) On or about 7/6/2021, at the 500-gallon diesel refueling area of the site, Cheektowaga, NY. A fire extinguisher, having a rating of not less than 20B:C, was not provided for the refueling area. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
339046401
|
0213600
|
2013-05-06
|
216 NORTHCREST AVENUE, CHEEKTOWAGA, NY, 14225
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-06
|
Emphasis |
N: TRENCH, P: TRENCH
|
Case Closed |
2013-11-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260652 A01 |
Issuance Date |
2013-06-07 |
Abatement Due Date |
2013-06-07 |
Current Penalty |
3500.0 |
Initial Penalty |
7000.0 |
Final Order |
2013-07-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OCCHINO PAVING CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 330267, CITATION NO. 1, ITEM NO. 8, AND WAS AFFIRMED AS A FINAL ORDER ISSUED ON 03/13/2013, WITH RESPECT TO A WORKPLACE LOCATED AT 630 WEST SOUTHSIDE AVENUE, CHERRY CREEK, NY 14723. 29 CFR 1926.652(a)(1): 29 CFR 1926.652(a)(1) Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) On or about 05/06/13, in a trench/excavation on construction site in front of 216 Northcrest Avenue, Cheektowaga, NY: An employee entered the west end of a trench that was 5 ft. 11 in. deep x approx. 3 ft. wide x 45 ft. long, and walked east on the trench bottom to signal the excavator operator who was installing a new water pipe in the trench using a sling attached to the excavator bucket. There was an existing copper water service line running crosswise in the trench, and they did not want to hit it. The north and south banks of the trench were vertical. No protective system was provided to protect the employee from a cave-in hazard. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
333302677
|
0213600
|
2012-05-07
|
630 WEST SOUTHSIDE AVENUE, CHERRY CREEK, NY, 14723
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-05-07
|
Emphasis |
N: TRENCH
|
Case Closed |
2013-09-06
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-09-20 |
Current Penalty |
0.0 |
Initial Penalty |
2100.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Waterline project in Cherry Creek, NY., no program had beendeveloped or implemented for the employees exposed to materials such as but not limited to gasoline and diesel fuel. ABATEMENT CERTIFICATION NEEDED |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-09-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8):The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (Construction Reference: 1926.59): a) Waterline Project in Cherry Creek, NY., no material safety data sheets were provided or were made available to the employees for materials such as but not limited to gasoline and diesel fuel ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-09-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) Waterline project in Cherry Creek, NY., no training had been provided for the employees potentially exposed to materials such as but not limited to gasoline and diesel fuel. ABATEMENT CERTIFICATION NEEDED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-08-21 |
Current Penalty |
1000.0 |
Initial Penalty |
2100.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) In front of 630 West Southside Avenue, two (2) employees observed working in a water line trench without any hard hats being worn to protect the employees from the potential of falling pieces of rock and dirt. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260152 A01 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-08-22 |
Current Penalty |
0.0 |
Initial Penalty |
2100.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(a)(1): Containers other than approved metal safety cans or DOT approved containers were used for the handling and use of flammable liquids in quantities of 5 gallons or less: a) Sitting on rear of company truck parked on side of West Southside Avenue, Cherry Creek, NY., a five-gallon plastic container of gasolline used to refuel pieces of equipment on the site was not the approved type of container to be used, container did not have a spring closing lid. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260152 G09 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-08-22 |
Current Penalty |
0.0 |
Initial Penalty |
2100.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.152(g)(9): Conspicuous and legible signs prohibiting smoking were not posted in service and refueling areas: a) Cherry Creek waterline project, one (1) five hundred gallon metal tank containing diesel fuel was not marked to indicate no smoking. Tank was used to refuel equipment on the site and was being stored near their temporary office facility. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2012-08-21 |
Current Penalty |
1000.0 |
Initial Penalty |
2800.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) In front of 630 West Southside Avenue, employees observed entering and exiting a six (6) foot deep trench without any ladder being provided. NO ABATEMENT CERTIFICATION NEEDED |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2012-08-21 |
Current Penalty |
1000.0 |
Initial Penalty |
2800.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) In front of 630 West Southside Avenue, Cherry Creek, NY., spoil pile was less than a foot from the edge of the trench on the Northeast corner of the trench. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2012-08-21 |
Abatement Due Date |
2012-08-22 |
Current Penalty |
1000.0 |
Initial Penalty |
4200.0 |
Contest Date |
2012-09-10 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) West Southside Avenue, Cherry Creek, NY. site, no competent person was available on site as evidence by the accumulation of water, lack of cave-in protection, and the lack of ladder in the trench to allow employees to gain access to and from the trench. These conditions should not have been present if a competent person was performing his assigned duties. ABATEMENT CERTIFICATION NEEDED |
|
|