346962376
|
0213600
|
2023-09-06
|
15 LAWRENCE BELL DRIVE, BUFFALO, NY, 14221
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-09-06
|
Case Closed |
2023-09-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1665204 |
Safety |
Yes |
|
|
346652043
|
0213600
|
2023-04-24
|
15 LAWRENCE BELL DRIVE, BUFFALO, NY, 14221
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-24
|
Case Closed |
2023-09-14
|
Related Activity
Type |
Complaint |
Activity Nr |
2021662 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2023-04-26 |
Abatement Due Date |
2023-05-18 |
Current Penalty |
2460.0 |
Initial Penalty |
4465.0 |
Contest Date |
2023-05-10 |
Final Order |
2023-09-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 04/24/2023 in the High Temp area; where employees perform servicing/maintenance activities such as entering the Haas Mill to clean out the mill without utilizing energy control procedures including de-energizing the equipment and locking the energy isolating device in the "off" position. ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-04-26 |
Abatement Due Date |
2023-05-18 |
Current Penalty |
1340.0 |
Initial Penalty |
2678.0 |
Contest Date |
2023-05-10 |
Final Order |
2023-09-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 04/24/2023, in the High Temp area; where a non-functioning proximity switch on the door of the Haas Mill (model TM-2P) allowed the mill to be operated with the guard door in the open position. ABATEMENT CERTIFICATION REQUIRED |
|
|