342368826
|
0213100
|
2017-06-02
|
1247 STATE STREET, SCHENECTADY, NY, 12302
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-06-02
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2023-02-01
|
Related Activity
Type |
Inspection |
Activity Nr |
1236906 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2017-08-17 |
Current Penalty |
2390.0 |
Initial Penalty |
2390.0 |
Final Order |
2017-10-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: (a) At the jobsite: On or prior to 6/02/17, the jobsite, tools, and equipment was not inspected by a competent person capable of identifying hazardous conditions, including but not limited to: discharged and insufficient number of fire extinguishers; Gehl telehandler with leaking hydraulic fittings; forklift-mounted personnel safety platform with damaged safety chain and gate closure; extension cords with cuts/tears and missing ground pins, and temporary stair without a handrail. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2017-08-17 |
Current Penalty |
1793.0 |
Initial Penalty |
1793.0 |
Final Order |
2017-10-06 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) During framing operations -- On or about 6/2/17, employees were not wearing protective helmets for protection from impact and falling objects. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2017-08-17 |
Current Penalty |
2987.0 |
Initial Penalty |
2987.0 |
Final Order |
2017-10-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) During framing operations: On or prior to 6/2/17, the personnel platform mounted on a Gehl 883 telehandler was not inspected for visible defects, including but not limited to: a hydraulic leak from boom extend cylinder, a safety chain which was damaged and unsecured to the forks, and a gate which did not properly close. The platform was used to lift two employees to the roof of the building to install plywood sheathing. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2017-08-17 |
Current Penalty |
2390.0 |
Initial Penalty |
2390.0 |
Final Order |
2017-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. (a) At the jobsite: On or prior to 6/2/17 -- employees were not trained in proper use of personal fall arrest system(s), including but not limited to how to use and adjust the full body harness. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-08-17 |
Current Penalty |
5975.0 |
Initial Penalty |
5975.0 |
Final Order |
2017-10-06 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system(s) (a) During roof sheathing -- On or about 6/2/17, two employees were exposed to fall hazards of approximately 30' when standing on the truss web/roof deck while installing plywood sheathing. The employees had exited a forklift-mounted personnel platform; no fall protection system was used. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260404 F06 |
Issuance Date |
2017-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-06 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) During framing: On or about 6/2/17, two extension cord(s) were used to power a Chicago Electric circular saw and a Porter-Cable pancake compressor; the cords had missing ground pins. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19260416 E01 |
Issuance Date |
2017-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) During framing: Extension cord used to power a Chicago Electric circular saw had visible cuts and damage; cord was tied to the rail of a Skyworks articulating boom lift. |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19260453 B02 V |
Issuance Date |
2017-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-06 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: (a) At the jobsite, during framing: On or about 6/2/17, two employees were not wearing harnesses while working from the basket of a Genie aerial lift. |
|
Citation ID |
03004 |
Citaton Type |
Other |
Standard Cited |
19261052 C01 I |
Issuance Date |
2017-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) First floor of building, NE side: On or prior to 6/2/17, basement entry stairs were not equipped with at least one handrail. |
|
|
340932532
|
0213100
|
2015-09-21
|
CROSSGATES COMMONS, ALBANY, NY, 12203
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-10-06
|
Emphasis |
L: FALL, L: LOCALTARG, P: FALL
|
Case Closed |
2019-05-01
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2015-12-11 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-02-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a) Work-Site - On or about September 21, 2015, employees secured a platform to the forks of a NES Rentals forklift without the supervision and direction of a competent person qualified to erect, move, or secure the platform. The platform was not designed for such use, and was lifted by the NES Rentals forklift exposing an employee to approximately 15 feet fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2015-12-11 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-02-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Work-Site - On or about September 21, 2015, an employee was not adequately protected from falls by the use of a guardrail system accompanied with the adequate personal fall arrest system working on a platform lifted up by a NES Rentals forklift approximately 15 feet in height above the ground. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260452 W04 |
Issuance Date |
2015-12-11 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-02-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(w)(4): Forklifts, trucks, similar motor vehicles or add-on motors were used to propel a scaffold that was not designed for such propulsion systems: a) Work-Site - On or about September 21, 2015, a NES Rentals forklift was used to lift a platform not designed for such use, exposing an employee to fall hazards of approximately 15 feet. |
|
|
313760332
|
0213100
|
2010-08-11
|
1630 CENTRAL AVE, ALBANY, NY, 12205
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-08-11
|
Case Closed |
2010-08-12
|
Related Activity
Type |
Inspection |
Activity Nr |
313758286 |
|
|
313758286
|
0213100
|
2010-04-12
|
1630 CENTRAL AVE, ALBANY, NY, 12205
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-04-12
|
Emphasis |
S: FALL FROM HEIGHT, S: ELECTRICAL, S: COMMERCIAL CONSTR, L: FALL
|
Case Closed |
2016-04-01
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-16 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-16 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260451 F04 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
5 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19260452 C03 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Nr Instances |
10 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01010 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01011 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01012 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01013 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01014 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2010-06-28 |
Abatement Due Date |
2010-07-11 |
Current Penalty |
800.0 |
Initial Penalty |
800.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
02 |
|
|
313755720
|
0213100
|
2009-12-01
|
1630 CENTRAL AVE, ALBANY, NY, 12205
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-12-01
|
Emphasis |
L: FALL
|
Case Closed |
2012-02-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2010-02-23 |
Abatement Due Date |
2010-02-26 |
Current Penalty |
200.0 |
Initial Penalty |
800.0 |
Contest Date |
2010-03-12 |
Final Order |
2010-11-29 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2010-02-23 |
Abatement Due Date |
2010-02-26 |
Current Penalty |
200.0 |
Initial Penalty |
800.0 |
Contest Date |
2010-03-12 |
Final Order |
2010-11-29 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260100 A |
Issuance Date |
2010-02-23 |
Abatement Due Date |
2010-02-26 |
Current Penalty |
200.0 |
Initial Penalty |
1600.0 |
Contest Date |
2010-03-12 |
Final Order |
2010-11-29 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260451 E01 |
Issuance Date |
2010-02-23 |
Abatement Due Date |
2010-02-26 |
Current Penalty |
200.0 |
Initial Penalty |
2000.0 |
Contest Date |
2010-03-12 |
Final Order |
2010-11-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
02003 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 |
Issuance Date |
2010-02-23 |
Abatement Due Date |
2010-02-26 |
Current Penalty |
200.0 |
Initial Penalty |
2000.0 |
Contest Date |
2010-03-12 |
Final Order |
2010-11-29 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
|
309376846
|
0215800
|
2005-10-28
|
ALUMNI HALL, SUNY DELHI, DELHI, NY, 13753
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-10-28
|
Emphasis |
L: FALL, N: TRENCH
|
Case Closed |
2012-11-01
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2005-11-30 |
Abatement Due Date |
2005-12-18 |
Current Penalty |
630.0 |
Initial Penalty |
1050.0 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2005-11-30 |
Abatement Due Date |
2005-12-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260096 |
Issuance Date |
2005-11-30 |
Abatement Due Date |
2005-12-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260152 A01 |
Issuance Date |
2005-11-30 |
Abatement Due Date |
2005-12-05 |
Current Penalty |
450.0 |
Initial Penalty |
750.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260302 B01 |
Issuance Date |
2005-11-30 |
Abatement Due Date |
2005-12-05 |
Current Penalty |
270.0 |
Initial Penalty |
450.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
01 |
|
|
302005269
|
0213100
|
1998-07-16
|
107TH ST. & 7TH AVE., TROY, NY, 12180
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1998-08-04
|
Emphasis |
N: TRENCH
|
Case Closed |
2003-07-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260250 B01 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Current Penalty |
200.0 |
Initial Penalty |
600.0 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Current Penalty |
200.0 |
Initial Penalty |
750.0 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260651 B04 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Current Penalty |
200.0 |
Initial Penalty |
750.0 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Current Penalty |
200.0 |
Initial Penalty |
1500.0 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Current Penalty |
200.0 |
Initial Penalty |
1500.0 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260404 B01 I |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260501 B14 |
Issuance Date |
1998-08-12 |
Abatement Due Date |
1998-08-17 |
Contest Date |
1998-09-15 |
Final Order |
1998-12-31 |
Nr Instances |
4 |
Nr Exposed |
3 |
Gravity |
01 |
|
|