Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-09
|
Case Closed |
2016-07-13
|
Related Activity
Type |
Referral |
Activity Nr |
1016469 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 M01 |
Issuance Date |
2016-02-03 |
Current Penalty |
6300.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-02-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(m)(1): Trucks shall not be driven up to anyone standing in front of a bench or other fixed object. a) Worksite, Wet End Coating Area: Employee operating Toyota forklift (Model #8FGU20, Serial #64484) drove up to and struck employee doing paper work in front of a fixed station control panel; on or about 9/2/15. NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement of this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 N04 |
Issuance Date |
2016-02-03 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-02-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(n)(4): The driver shall be required to slow down and sound the horn at cross aisles and other locations where vision is obstructed. If the load being carried obstructs forward view, the driver shall be required to travel with the load trailing. a) Worksite, Wet End Area: Employee operating Toyota forklift (Model #8FGU20, Serial #64484) to transport a pallet of adhesive roll (approximately 68 inches in height, 40 inches in diameter) did not travel with the load backward causing him to strike another employee doing paper work at a station control. The operator's view was obstructed; on or about 9/2/15 NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement of this violation as normally required by 29 CFR 1903.19. |
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-03-27
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-10-17
|
Related Activity
Type |
Referral |
Activity Nr |
971468 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2015-11-10 |
Current Penalty |
6300.0 |
Initial Penalty |
6300.0 |
Final Order |
2015-10-20 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Workplace, Solvent Mixing Dept. - The employer did not develop, document and utilize procedures to control hazardous electrical and mechanical energy for employees performing cleaning, maintenance, repair or adjustments to Marathon Solvent mixing machine, Model EL283TTGN18038AAL; on or about 3/27/15. b) Workplace, Solvent Mixing Dept. - The employer did not develop, document and utilize procedures to control hazardous electrical and mechanical energy for employees performing cleaning, maintenance, repair or adjustments to S & H Equipment Corp. mixing machine, Model HVR 25, Serial #76-1068; on or about 3/27/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2015-11-10 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2015-10-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) Workplace, Solvent Mixing Dept.- There were no devices for isolating machines or equipment from electrical or mechanical energy sources when employees performed cleaning or maintenance on the Marathon Solvent mixing machine, Model EL283TTGN18038AAL; on or about 3/27/15. b) Workplace, Solvent Mixing Dept. - There were no devices for isolating machines or equipment from electrical or mechanical energy sources when employees performed cleaning or maintenance on the S & H Equipment Corp. mixing machine, Model HVR 25, Serial #76-1068; on or about 3/27/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2015-11-10 |
Current Penalty |
0.0 |
Initial Penalty |
6300.0 |
Final Order |
2015-10-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) Workplace, Solvent Mixing Dept. -The employees were performing cleaning functions on machines such as Marathon Solvent mixing machine, Model EL283TTGN18038AAL and S & H Equipment Corp. mixing machine, Model HVR 25, Serial #76-1068 without having received adequate instruction on the safe application, usage, and removal of the electrical and mechanical energy controls are acquired by employees; on or about 3/27/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2015-10-01 |
Current Penalty |
6300.0 |
Initial Penalty |
6300.0 |
Final Order |
2015-10-20 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Workplace, Solvent Mixing Dept. - The Marathon Solvent Mixing Machine, Model EL283TTGN18038AAL, did not have a fixed guard protecting the employee from rotating parts of the shaft and mixing blades; on or about 3/27/15. b) Workplace, Solvent Mixing Dept. - The S & H Mixing Machine, Model HVR 25, Serial #76-1068, did not have a fixed guard protecting the employee from rotating parts of the shaft and mixing blades; on or about 3/27/15. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
|