331898452
|
0215800
|
2012-01-19
|
110 CREEKSIDE DRIVE, PAINTED POST, NY, 14870
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-01-19
|
Emphasis |
L: FALL, N: CTARGET
|
Case Closed |
2013-02-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2012-02-17 |
Current Penalty |
2100.0 |
Initial Penalty |
3000.0 |
Contest Date |
2012-03-08 |
Final Order |
2012-08-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt or harness with lanyard attached to the boom or basket was not worn when working from an aerial lift: a) Building "A", on or about 1/19/12: An employee working from a boom lift was not protected from falling in that the leg straps of the harness were not secured. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2012-02-17 |
Current Penalty |
2100.0 |
Initial Penalty |
3000.0 |
Contest Date |
2012-03-08 |
Final Order |
2012-08-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level were not be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Building "A", on or about 1/19/12: Employees engaged in framing work were not protected from falling 19 feet 4 inches to grade. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260502 D19 |
Issuance Date |
2012-02-17 |
Current Penalty |
1200.0 |
Initial Penalty |
1800.0 |
Contest Date |
2012-03-08 |
Final Order |
2012-08-27 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(19): Personal fall arrest systems and components subjected to impact loading were not immediately removed from service: a) Building "A", on or about 1/19/12: The lanyard being used for fall protection from boom lift had been subject to an impacting load and was not removed from service. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2012-02-17 |
Abatement Due Date |
2012-02-22 |
Current Penalty |
0.0 |
Initial Penalty |
2400.0 |
Contest Date |
2012-03-08 |
Final Order |
2012-08-27 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) Building "A", on or about 1/19/12: Employees that were exposed to fall hazards were not provided with training to recognize and avoid the hazard. |
|
|
11871050
|
0215600
|
1974-07-22
|
JEWEL AVENUE AT 141ST STREET, Fluvanna, NY, 11367
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1974-07-22
|
Emphasis |
N: TREX
|
Case Closed |
1974-09-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260652 H |
Issuance Date |
1974-07-30 |
Abatement Due Date |
1974-08-02 |
Current Penalty |
65.0 |
Initial Penalty |
65.0 |
Contest Date |
1974-08-15 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260650 E |
Issuance Date |
1974-07-30 |
Abatement Due Date |
1974-08-02 |
Current Penalty |
35.0 |
Initial Penalty |
35.0 |
Contest Date |
1974-08-15 |
Nr Instances |
1 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1974-07-30 |
Abatement Due Date |
1974-08-15 |
Contest Date |
1974-08-15 |
Nr Instances |
1 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19040005 A |
Issuance Date |
1974-07-30 |
Abatement Due Date |
1974-08-15 |
Contest Date |
1974-08-15 |
Nr Instances |
1 |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260652 C |
Issuance Date |
1974-07-30 |
Abatement Due Date |
1974-08-02 |
Current Penalty |
600.0 |
Initial Penalty |
600.0 |
Contest Date |
1974-08-15 |
Nr Instances |
1 |
|
|
11798808
|
0215000
|
1974-06-27
|
1 AVENUE AND EAST 100 STREET, New York -Richmond, NY, 10013
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1974-06-27
|
Emphasis |
N: TREX
|
Case Closed |
1984-03-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260201 A01 |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
3 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260650 F |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
1 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
2 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19260350 A09 |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
2 |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19260350 A01 |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
1 |
|
Citation ID |
01006 |
Citaton Type |
Other |
Standard Cited |
19260302 B07 |
Issuance Date |
1974-07-10 |
Abatement Due Date |
1974-07-24 |
Nr Instances |
1 |
|
|