Search icon

CRYOMECH, INC.

Company Details

Name: CRYOMECH, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 08 Jul 1968 (57 years ago)
Entity Number: 1864002
ZIP code: 13211
County: Onondaga
Place of Formation: New York
Address: 6682 Moore Road, SYRACUSE, NY, United States, 13211

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Unique Entity ID

Unique Entity ID Expiration Date Physical Address Mailing Address
PGVLC26LANK4 2025-02-20 6682 MOORE RD, SYRACUSE, NY, 13211, 2111, USA 6682 MOORE ROAD, SYRACUSE, NY, 13211, 2106, USA

Business Information

Doing Business As CRYOMECH INC
Congressional District 22
State/Country of Incorporation NY, USA
Activation Date 2024-02-26
Initial Registration Date 2001-07-16
Entity Start Date 1968-07-08
Fiscal Year End Close Date Dec 31

Service Classifications

NAICS Codes 333415

Points of Contacts

Electronic Business
Title PRIMARY POC
Name JAMES SAGAZIO
Address 6682 MOORE RD, SYRACUSE, NY, 13211, 2106, USA
Government Business
Title PRIMARY POC
Name JAMES SAGAZIO
Address 6682 MOORE RD, SYRACUSE, NY, 13211, 2106, USA
Past Performance Information not Available

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
55537 Active U.S./Canada Manufacturer 1976-10-30 2024-03-10 2029-02-26 2025-02-20

Contact Information

POC JAMES SAGAZIO
Phone +1 315-455-2555
Fax +1 315-455-2544
Address 6682 MOORE RD, SYRACUSE, NY, 13211 2111, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
CRYOMECH, INC. 401(K) PLAN 2013 160900336 2014-05-06 CRYOMECH, INC. 94
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1990-07-01
Business code 339900
Sponsor’s telephone number 3154552555
Plan sponsor’s address 113 FALSO DRIVE, SYRACUSE, NY, 132112106

Signature of

Role Plan administrator
Date 2014-05-06
Name of individual signing PETER E. GIFFORD

Chief Executive Officer

Name Role Address
RICHARD DAUSMAN Chief Executive Officer 6682 MOORE ROAD, SYRACUSE, NY, United States, 13211

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 6682 Moore Road, SYRACUSE, NY, United States, 13211

History

Start date End date Type Value
2014-09-24 2023-03-13 Shares Share type: PAR VALUE, Number of shares: 300000, Par value: 0.01
2014-09-24 2018-07-02 Address 113 FALSO DR, SYRACUSE, NY, 13211, USA (Type of address: Chief Executive Officer)
1968-07-08 2014-09-24 Address 829 OSTROM AVE, SYRACUSE, NY, 00000, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
220303000384 2022-03-03 BIENNIAL STATEMENT 2020-07-01
180702006286 2018-07-02 BIENNIAL STATEMENT 2018-07-01
160909006277 2016-09-09 BIENNIAL STATEMENT 2016-07-01
140924002060 2014-09-24 BIENNIAL STATEMENT 2014-07-01
140924000651 2014-09-24 CERTIFICATE OF AMENDMENT 2014-09-24
941103000428 1994-11-03 ERRONEOUS ENTRY 1994-11-03
DP-12238 1977-12-20 DISSOLUTION BY PROCLAMATION 1977-12-20
692788-6 1968-07-08 CERTIFICATE OF INCORPORATION 1968-07-08

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PURCHASE ORDER AWARD FA282308P0207 2008-09-09 2008-10-21 2008-10-21
Unique Award Key CONT_AWD_FA282308P0207_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 9454.00
Current Award Amount 9454.00
Potential Award Amount 9454.00

Description

Title ADSORBER; CHARCOAL CP900, PN 72-62
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 6636: ENVIRONMENTAL CHAMBERS & RELATED EQ

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 132112106
DELIVERY ORDER AWARD 0006 2008-09-09 2008-12-31 2008-12-31
Unique Award Key CONT_AWD_0006_9700_FA830706D0008_9700
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 34400.00
Current Award Amount 237385.00
Potential Award Amount 237385.00

Description

Title CRYOMECH ROTARY VALVE COMPLETE ASSEMBLY
NAICS Code 333999: ALL OTHER MISCELLANEOUS GENERAL PURPOSE MACHINERY MANUFACTURING
Product and Service Codes 4820: VALVES, NONPOWERED

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 13211
PO AWARD NNG08ED51P 2008-08-08 2008-09-29 2008-09-29
Unique Award Key CONT_AWD_NNG08ED51P_8000_-NONE-_-NONE-
Awarding Agency National Aeronautics and Space Administration
Link View Page

Description

Title PT405 REMOTE MOTOR CRYOREFRIGERATOR AND PT405 BELLOWS ASSSEMBLIES
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 6640: LABORATORY EQUIPMENT AND SUPPLIES

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, 132112106
No data IDV FA830706D0008 2008-07-17 No data No data
Unique Award Key CONT_IDV_FA830706D0008_9700
Awarding Agency Department of Defense
Link View Page

Description

Title CRYOMECH ROTARY VALVE COMPLETE ASSEMBLY
NAICS Code 333999: ALL OTHER MISCELLANEOUS GENERAL PURPOSE MACHINERY MANUFACTURING
Product and Service Codes 4820: VALVES, NONPOWERED

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, 13211
DELIVERY ORDER AWARD 0005 2008-05-27 2008-08-29 2009-07-16
Unique Award Key CONT_AWD_0005_9700_FA830706D0008_9700
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 102040.00
Current Award Amount 161600.00
Potential Award Amount 233070.00

Description

Title CRYOMECH STEM SEAL W/O-RING
NAICS Code 333999: ALL OTHER MISCELLANEOUS GENERAL PURPOSE MACHINERY MANUFACTURING
Product and Service Codes 5330: PACKING AND GASKET MATERIALS

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 13211
PO AWARD NNG09DA06P 2009-07-30 2009-11-27 2009-11-27
Unique Award Key CONT_AWD_NNG09DA06P_8000_-NONE-_-NONE-
Awarding Agency National Aeronautics and Space Administration
Link View Page

Description

Title NASA/GSFC HAS A REQUIREMENT FOR A COLD HEAD REMOTE MOTOR CONNECTING LINE COMPRESSOR PACKAGE.
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 4110: REFRIGERATION EQUIPMENT

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, 132112106
PO AWARD DOCSB134109SU0574 2009-08-03 2010-01-10 2011-01-09
Unique Award Key CONT_AWD_DOCSB134109SU0574_1341_-NONE-_-NONE-
Awarding Agency Department of Commerce
Link View Page

Description

Title LIQUID HELIUM PLANT
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 6640: LABORATORY EQUIPMENT AND SUPPLIES

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, 132112106
PURCHASE ORDER AWARD N6553809M0076 2009-06-22 2009-12-30 2009-12-30
Unique Award Key CONT_AWD_N6553809M0076_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 69369.00
Current Award Amount 69369.00
Potential Award Amount 69369.00

Description

Title FIRST STATUS REPORT
NAICS Code 541712: RESEARCH AND DEVELOPMENT IN THE PHYSICAL, ENGINEERING, AND LIFE SCIENCES (EXCEPT BIOTECHNOLOGY)
Product and Service Codes AD21: SERVICES (BASIC)

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 132112106
PURCHASE ORDER AWARD DOCRA134109SU0767 2009-05-01 2009-06-12 2009-06-12
Unique Award Key CONT_AWD_DOCRA134109SU0767_1330_-NONE-_-NONE-
Awarding Agency Department of Commerce
Link View Page

Award Amounts

Obligated Amount 4164.00
Current Award Amount 4164.00
Potential Award Amount 4164.00

Description

Title CRYOMECH PULSE TUBE COLDHEAD UPGRADE TO REMOTE MOTER
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 6695: COMBINATION & MISC INSTRUMENTS

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 132112106
PURCHASE ORDER AWARD DOCRA134109SU0243 2009-01-06 2009-02-18 2009-02-18
Unique Award Key CONT_AWD_DOCRA134109SU0243_1330_-NONE-_-NONE-
Awarding Agency Department of Commerce
Link View Page

Award Amounts

Obligated Amount 11886.00
Current Award Amount 11886.00
Potential Award Amount 11886.00

Description

Title FLEXIBLE LINE FOR CRYOCOOLERS
NAICS Code 333415: AIR-CONDITIONING AND WARM AIR HEATING EQUIPMENT AND COMMERCIAL AND INDUSTRIAL REFRIGERATION EQUIPMENT MANUFACTURING
Product and Service Codes 4130: REFRIGERATION & AIR CONDITION COMP

Recipient Details

Recipient CRYOMECH, INC.
UEI PGVLC26LANK4
Legacy DUNS 002254464
Recipient Address UNITED STATES, 113 FALSO DR, SYRACUSE, ONONDAGA, NEW YORK, 132112106

USAspending Awards. Financial Assistance

FAIN Awarding Agency Assistance Listings Start Date End Date Description
4121635008 Small Business Administration 59.041 - 504 CERTIFIED DEVELOPMENT LOANS No data No data TO ASSIST SMALL BUSINESS CONCERNS BY PROVIDING LONG TERM FINANCING THROUGH THE SALE OF DEBENTURES TO THE PRIVATE SECTOR
Recipient CRYOMECH, INC.
Recipient Name Raw CRYOMECH INC.
Recipient UEI PGVLC26LANK4
Recipient DUNS 002254464
Recipient Address 127 FALSO DRIVE., SYRACUSE, ONONDAGA, NEW YORK, 13211-0000, UNITED STATES
Obligated Amount 0.00
Non-Federal Funding 0.00
Original Subsidy Cost 6765.00
Face Value of Direct Loan 330000.00
Link View Page

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341962884 0215800 2016-12-08 113 FALSO DRIVE, MATTYDALE, NY, 13211
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2016-12-21
Emphasis N: LEAD
Case Closed 2017-03-24

Related Activity

Type Complaint
Activity Nr 1160301
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19101025 H01
Issuance Date 2017-03-07
Abatement Due Date 2017-03-20
Current Penalty 2750.25
Initial Penalty 3667.0
Final Order 2017-03-17
Nr Instances 3
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: a) Clean room and ball room, on or about 12/21/16: A housekeeping program was not developed to decontaminate lead from surfaces including , but not limited to benches in ball room and service benches in clean room. Ball room bench was found to contain lead residue; employee's work bench in clean room was found to contain residue and clean room service bench closest to ball room was found to contain lead residue. Abatement certification must be submitted for this item.
336322805 0215800 2012-09-13 113 FALSO DRIVE, SYRACUSE, NY, 13211
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-09-13
Emphasis N: AMPUTATE, N: SSTARG11
Case Closed 2012-12-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 2677.5
Initial Penalty 3825.0
Final Order 2012-11-29
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) Bldg. 2, Water Tower Mezzanine, on or about 9/13/12: The water tower mezzanine, approximately 8 feet from floor level, was not provided with standard guardrails. b) Bldg. 1, Shipping Area, Water Tower Mezzanine, on or about 9/13/12: The water tower mezzanine, approximately 9 feet from floor level, was not provided with standard guardrails. Abatement certification must be submitted for these items.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100027 D03
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 1606.5
Initial Penalty 2295.0
Final Order 2012-11-29
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(d)(3): The side rails of through or side-step ladder extensions did not extend 3 1/2 feet above parapets and landings: a) Bldg. 3, Warehouse, on or about 9/13/12: The side rails for a fixed ladder to an overhead storage area/utility area over the Inspection Room did not extend 3 1/2 feet above the landing. b) Bldg. 2, Water Tower mezzanine, on or about 9/13/12: The side rails for a fixed ladder to the water tower mezzanine did not extend 3 1/2 feet about the landing. Abatement certification must be submitted for these items.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100106 D04 I
Issuance Date 2012-10-19
Abatement Due Date 2012-12-18
Current Penalty 2677.5
Initial Penalty 3825.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height: a) Bldg. 2, Flammable Storage Room, on or about 9/13/12: Flammable storage room was not provided with raised sills or ramps. Abatement certification must be submitted for this item.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100106 D04 IV
Issuance Date 2012-10-19
Abatement Due Date 2012-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(d)(4)(iv): Inside flammable or combustible liquid storage room(s) were not provided with either a gravity or a mechanical exhaust ventilation system: a) Bldg. 2, Flammable Storage Room, on or about 9/13/12: No ventilation was provided for the flammable storage room. Abatement certification must be provided for this item.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 2677.5
Initial Penalty 3825.0
Final Order 2012-11-29
Nr Instances 15
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and ingoing nip points: a) Bldg. 3, on or about 9/13/12: Unused portion of blade on a Cosen horizontal bandsaw #12 was not adequately guarded. b) Bldg. 3, Production Machine Shop, on or about 9/13/12: Rotating chuck and jaws were not guarded on a South Bend lathe #37, Clausing lathe #16, South Bend Turn-nado lathe #18, and Clausing lathe #8. c) Bldg. 3, Production Machine Shop, on or about 9/13/12: Rotating chucks on a Fosdick two spindle drill press #6 were not guarded. d) Bldg. 3, Production Machine Shop, on or about 9/13/12: Rotating spindle end and nut projections on a Westward grinder with buffing wheels were not guarded. e) Bldg. 3, Production Machine Shop, on or about 9/13/12: Rotating chuck on a Sunnen honing machine #21 was not guarded. f) Bldg. 2, Oil Processing Area, on or about 9/13/12: Rotating spindle end and nut projections on an 8 inch bench grinder with wire brush attachment were not guarded. g) Bldg. 2, Compressor Assembly, on or about 9/13/12: Rotating spindle end and nut projections on a Quality 6 inch bench grinder with buffing wheels were not guarded. h) Bldg. 2, Compressor Assembly, on or about 9/13/12: Rotating spindle and chuck on an Edlund drill press were not guarded. i) Bldg. 2, Base Tube Assembly, Buffing Room, on or about 9/13/12: Rotating shafts and spindle end and nut projections on a Baldor pedestal buffer were not guarded. j) Bldg. 2, Base Tube Assembly, on or about 9/13/12: Rotating chuck and extended jaws on a Clausing lathe #23 were not guarded. k) Bldg. 2, Base Tube Assembly, on or about 9/13/12: Rotating chuck on a South Bend Turn-nado lathe was not guarded. Abatement certification must be submitted for these items.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Bldg. 3, Production Machine Shop, on or about 9/13/12: A DeWalt pedestal grinder was not secured to prevent walking or moving. Abatement certification must be submitted for this item.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 1606.5
Initial Penalty 2295.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Base Tube Assembly, on or about 9/13/12: Pulleys driving a Bridgeport milling machine #05 were not adequately guarded. Abatement certification must be submitted for this item.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) Base Tube Assembly, on or about 9/13/12: V belt driving a Bridgeport milling machine #05 was not adequately guarded. Abatement certification must be submitted for this item.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100303 F02
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 1606.5
Initial Penalty 2295.0
Final Order 2012-11-29
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Bldg. 2, Compressor Assembly, Electrical Area, on or about 9/13/12: A circuit breaker panel labeled PP2, did not have all of the breakers labeled as to what they controlled. b) Bldg. 1, Test Area, Electrical Area, on or about 9/13/12: A circuit breaker panel labeled Panel P 260V Clean Room, did not have all of the breakers labeled as to what they controlled. Abatement certification must be submitted for these items.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100304 F01 IV
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 3
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a) Bldg. 1, Compressor Run In Wall, on or about 9/13/12: Three circuit breaker panels were blocked by equipment. Abatement certification must be submitted for this item.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 1606.5
Initial Penalty 2295.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Bldg. 3, Honing Area, on or about 9/13/12: A Dayton pedestal fan was not grounded in that the ground pin was missing from the plug end. Abatement certification must be submitted for this item.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19100304 G06 VI
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(6)(vi): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded: a) Flex Line Area, on or about 9/13/12: A Lasko box fan was not grounded in that it was only a two wire cord. Abatement certification must be submitted for this item.
Citation ID 01008A
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 1606.5
Initial Penalty 2295.0
Final Order 2012-11-29
Nr Instances 4
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Bldg. 3, Warehouse, on or about 9/13/12: A circuit breaker panel had a knockout missing on the right side. b) Bldg. 1, Test Area, Electrical equipment area, on or about 9/13/12: A circuit breaker panel marked HV-1A 480V had one blank missing. c) Bldg. 1, Compressor Run In Wall, on or about 9/13/12: Circuit breaker panel labeled Panel E, had a knockout missing on the left side. d) Bldg. 1, R&D Lab, on or about 9/13/12: Circuit breaker panel labeled Panel #2 BR, next to the exit, had one blank missing. Abatement certification must be submitted for these items.
Citation ID 01008B
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 2
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Bldg. 2, outside lunch room, on or about 9/13/12: An LB cover was missing on the electrical conduit for cooling tower 3. b) Bldg. 1, Compressor Run In Wall, on or about 9/13/12: A junction box below the 50 HZ circuit breaker panel had a cover missing. Abatement certification must be submitted for these items.
Citation ID 01008C
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 2
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Bldg. 2, Compressor Assembly, Electrical Panel Assembly Area, on or about 9/13/12: Two strip outlets attached to a peg board on the workbench were being used as permanent wiring. b) Bldg. 2, Base Tube Assembly, on or about 9/13/12: A strip outlet providing current to a packing press was being used as permanent wiring. Abatement certification must be submitted for these items.
Citation ID 01008D
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Bldg. 3, Honing Area, on or about 9/13/12: Flexible cord providing current to a Dayton pedestal fan was not provided with strain relief at the motor fitting. Abatement certification must be submitted for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 A04
Issuance Date 2012-10-19
Abatement Due Date 2012-10-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Bldg. 2, Flammable Storage Room, on or about 9/13/12: The emergency light on the exit door was not functioning. Abatement certification must be submitted for this item.
Citation ID 02002
Citaton Type Other
Standard Cited 19100178 L04 III
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 3
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years a) At the establishment, on or about 9/13/12: Evaluations of 3 forklift operators had not been conducted every three years in that the operators were due for an evaluation in April, 2012. Abatement certification must be submitted for this item.
Citation ID 02003
Citaton Type Other
Standard Cited 19100215 B09
Issuance Date 2012-10-19
Abatement Due Date 2012-11-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-29
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Bldg. 3, Production Machine Shop, on or about 9/13/12: Cincinnati grinder was not provided with a tongue guard for the left abrasive wheel. Abatement certification must be submitted for this item.
302695358 0215800 2001-04-10 113 FALSO DR., SYRACUSE, NY, 13221
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2001-04-16
Emphasis S: LEAD
Case Closed 2001-06-11

Related Activity

Type Complaint
Activity Nr 203097472
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2001-05-03
Abatement Due Date 2001-05-21
Nr Instances 1
Nr Exposed 23
Gravity 01
107696825 0215800 1999-10-01 113 FALSO DR., SYRACUSE, NY, 13221
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 1999-10-15
Emphasis S: AMPUTATIONS
Case Closed 1999-12-17

Related Activity

Type Complaint
Activity Nr 200874931
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100106 E06 I
Issuance Date 1999-10-20
Abatement Due Date 1999-10-25
Current Penalty 292.5
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100106 E06 II
Issuance Date 1999-10-20
Abatement Due Date 1999-10-25
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 1999-10-18
Abatement Due Date 1999-10-21
Current Penalty 292.5
Initial Penalty 450.0
Nr Instances 2
Nr Exposed 5
Gravity 01
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 1999-10-20
Abatement Due Date 1999-11-22
Current Penalty 292.5
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 10
Gravity 01
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 1999-10-20
Abatement Due Date 1999-10-25
Nr Instances 1
Nr Exposed 10
Gravity 01
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 1999-10-20
Abatement Due Date 1999-11-12
Nr Instances 1
Nr Exposed 10
Gravity 01
Citation ID 02001
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1999-10-20
Abatement Due Date 1999-11-22
Nr Instances 1
Nr Exposed 10
Gravity 00
12050639 0215800 1977-01-04 314 AINSLEY DRIVE, Syracuse, NY, 13210
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1977-01-04
Case Closed 1977-02-09

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100022 B01
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01002
Citaton Type Other
Standard Cited 19100037 Q01
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01003
Citaton Type Other
Standard Cited 19100157 A02
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01004
Citaton Type Other
Standard Cited 19100157 A06
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01005
Citaton Type Other
Standard Cited 19100157 D03 I
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 2
Citation ID 01006
Citaton Type Other
Standard Cited 19100212 A05
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01007
Citaton Type Other
Standard Cited 19100212 B
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01008
Citaton Type Other
Standard Cited 19100252 A02 IVC
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1
Citation ID 01009
Citaton Type Other
Standard Cited 19100309 A 040004
Issuance Date 1977-01-18
Abatement Due Date 1977-01-31
Nr Instances 1

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8727777108 2020-04-15 0248 PPP 113 Falso Drive, Syracuse, NY, 13211
Loan Status Date 2021-04-20
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 1857278
Loan Approval Amount (current) 1857278
Undisbursed Amount 0
Franchise Name -
Lender Location ID 46391
Servicing Lender Name Manufacturers and Traders Trust Company
Servicing Lender Address One M & T Plaza, 15th Fl, BUFFALO, NY, 14203
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Syracuse, ONONDAGA, NY, 13211-0001
Project Congressional District NY-22
Number of Employees 138
NAICS code 333249
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 46391
Originating Lender Name Manufacturers and Traders Trust Company
Originating Lender Address BUFFALO, NY
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 1874629.56
Forgiveness Paid Date 2021-03-31

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P0358521 CRYOMECH, INC. CRYOMECH INC PGVLC26LANK4 6682 MOORE RD, SYRACUSE, NY, 13211-2111
Capabilities Statement Link -
Phone Number 315-455-2555
Fax Number 315-455-2544
E-mail Address jsagazio@cryomech.com
WWW Page -
E-Commerce Website -
Contact Person JAMES SAGAZIO
County Code (3 digit) 067
Congressional District 22
Metropolitan Statistical Area 8160
CAGE Code 55537
Year Established 1968
Accepts Government Credit Card Yes
Legal Structure Subchapter S Corporation
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business
Business Development Servicing Office SYRACUSE DISTRICT OFFICE (SBA office code 0248)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords cryorefrigerator, cryostat, liquid nitroge plant, pulse tube
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level $0
Description Construction Bonding Level (aggregate)
Level $0
Description Service Bonding Level (per contract)
Level $0
Description Service Bonding Level (aggregate)
Level $0

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 333415
NAICS Code's Description Air?Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Court Cases

Docket Number Nature of Suit Filing Date Disposition
1100279 Patent 2011-03-11 voluntarily
Circuit Second Circuit
Origin original proceeding
Jurisdiction federal question
Jury Demand Plaintiff demands jury
Demanded Amount 0
Termination Class Action Missing
Procedural Progress no court action
Nature Of Judgment no monetary award
Judgement missing
Arbitration On Termination Missing
Office 5
Filing Date 2011-03-11
Termination Date 2011-06-22
Section 2201
Sub Section DJ
Status Terminated

Parties

Name CRYOMECH, INC.
Role Plaintiff
Name TOSHIBA CORPORATION,
Role Defendant

Date of last update: 15 Mar 2025

Sources: New York Secretary of State