Search icon

EXTERIOR INNOVATIONS, INC.

Company Details

Name: EXTERIOR INNOVATIONS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 04 Jan 1995 (30 years ago)
Date of dissolution: 29 Jul 2009
Entity Number: 1881211
ZIP code: 14031
County: Erie
Place of Formation: New York
Principal Address: 10333 KELLER RD, CLARENCE, NY, United States, 14031
Address: 10333 KELLER ROAD, CLARENCE, NY, United States, 14031

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
KARLA DEACON DOS Process Agent 10333 KELLER ROAD, CLARENCE, NY, United States, 14031

Chief Executive Officer

Name Role Address
KARLA DEACON Chief Executive Officer 10333 KELLER RD, CLARENCE, NY, United States, 14031

Filings

Filing Number Date Filed Type Effective Date
DP-1755781 2009-07-29 DISSOLUTION BY PROCLAMATION 2009-07-29
010111002022 2001-01-11 BIENNIAL STATEMENT 2001-01-01
990113002272 1999-01-13 BIENNIAL STATEMENT 1999-01-01
970403002575 1997-04-03 BIENNIAL STATEMENT 1997-01-01
950104000041 1995-01-04 CERTIFICATE OF INCORPORATION 1995-01-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346108137 0215800 2022-07-28 4285 NY-31, CLAY, NY, 13041
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2022-07-28
Emphasis L: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260104 A
Issuance Date 2022-11-16
Abatement Due Date 2022-11-29
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-12-13
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.104(a): The employer did not ensure that any lifeline, safety belt, or lanyard actually subjected to in-service loading, as distinguished from static load testing, shall be immediately removed from service and shall not be used again for employee safeguarding. a)Site located at 4285 NY-31, Clay, NY 13041: On or about 7/28/2022, the employer did not prevent employee exposure to fall hazards when employees utilized a lanyard anchored to the roof had been subjected to a fall (lanyards shock absorber stitching had been torn open).
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2022-11-16
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-12-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): The employer did not ensure that each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide. a) Site located at 4285 NY-31, Clay, NY 13041: On or about 7/28/2022, the employer did not prevent possible exposure to fall hazards when a roof scaffold with a gap of 4-6 inches between adjacent platforms was constructed onsite and utilized by employee(s) during siding installation activities.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-11-16
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-12-13
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Employer did not ensure that the portable ladders used for access to the upper landing surface had ladder side rails that extended at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. a) Site located at 4285 NY-31, Clay, NY 13041: On or about 7/28/2022, the employer did not provide ladders for roof access that were 3 feet above the upper landing surface, exposing workers to falls of greater than 10 feet.
Citation ID 01004
Citaton Type Repeat
Standard Cited 19260451 G01 VII
Issuance Date 2022-11-16
Current Penalty 6216.0
Initial Penalty 6216.0
Final Order 2022-12-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold more than 10 feet (3.1m) above a lower level, not otherwise specified in paragraphs (g)(1)(I) through (g)(1)(vi) of this section, was not protected from falling to that lower level by use of personal fall arrest systems or guardrail systems meeting the requirement of paragraph (g)(4) of this section: a) Site located at 4285 NY-31, Clay, NY 13041: On or about 7/28/2022, the employer failed to prevent employees exposure to fall hazards when employee(s) utilized a roof scaffold without guardrails or the use of a personal fall arrest system. EXTERIOR INNOVATIONS PREVIOUSLY RYAN LAFAVE DBA EXTERIOR INNOVATIONS was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1926.501 (B)(13)), which was contained in OSHA inspection number 1215544, citation number 1, item number 2 and was affirmed as a final order on 12/18/2017, with respect to a workplace located at 748 Beech street, Syracuse, NY 13209.