344586169
|
0216000
|
2019-12-04
|
41 COHAWNEY ROAD, SCARSDALE, NY, 10583
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-12-04
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-02-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2020-04-15 |
Current Penalty |
1735.0 |
Initial Penalty |
1735.0 |
Final Order |
2020-09-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A) Exterior, On the ground: An employee was exposed to head injuries while working below another employee above. Both employees were conducting roofing activities. The employee below was not protected by a hard hat or protective helmet, on or about December 4th, 2019. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2020-04-15 |
Current Penalty |
4048.0 |
Initial Penalty |
4048.0 |
Final Order |
2020-09-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) Roof of the structure: Employees were exposed to fall hazards of approximately 20 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about December 4th, 2019. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B06 |
Issuance Date |
2020-04-15 |
Current Penalty |
4048.0 |
Initial Penalty |
4048.0 |
Final Order |
2020-09-24 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement. A) Exterior, On the roof: An employee was exposed to fall/ladder slip hazards while using an extension ladder that was laying on a pitched roof, on or about December 4th, 2019. |
|
|
332792563
|
0216000
|
2012-02-27
|
15 FENIMORE RD., SCARSDALE, NY, 10583
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-03-15
|
Emphasis |
L: FALL
|
Case Closed |
2012-08-14
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2012-04-02 |
Abatement Due Date |
2012-04-05 |
Current Penalty |
1188.0 |
Initial Penalty |
1980.0 |
Final Order |
2012-04-30 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: location: front of house on or about: 2/27/12 a) Employees, working below a scaffold loaded with slate shingles, were not provided with hard hats. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 II |
Issuance Date |
2012-04-02 |
Abatement Due Date |
2012-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards. location: front of house on or about: 2/27/12 a) Employees were working below a scaffold loaded with slate shingles. The scaffold did not have a toeboard. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2012-04-02 |
Abatement Due Date |
2012-04-05 |
Current Penalty |
1188.0 |
Initial Penalty |
1980.0 |
Final Order |
2012-04-30 |
Nr Instances |
12 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: location: front of house on or about: 2/27/12 a) Employees were performing roofing work from tubular welded frame scaffolding. The scaffold, set up in the grass and soil, had base plates but did not rest on mud sills. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2012-04-02 |
Current Penalty |
2772.0 |
Initial Penalty |
4620.0 |
Final Order |
2012-04-30 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: location: front of house on or about: 2/27/12 a) Employees, performing roofing work from tubular welded frame scaffolding, were not provided with fall protection. The employees were exposed to a fall between 10'3" and 10'8". NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2012-04-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-04-30 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: front of house on or about: 2/27/12 a) Employees were performing roofing work from tubular welded frame scaffolding. The employees were not provided with scaffold safety training. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
|
311281588
|
0216000
|
2008-01-22
|
30 HEATHCOAT ROAD, SCARSDALE, NY, 10583
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-01-22
|
Emphasis |
L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2008-04-23
|
Related Activity
Type |
Complaint |
Activity Nr |
205180714 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2008-02-13 |
Abatement Due Date |
2008-02-19 |
Current Penalty |
1200.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2008-02-13 |
Abatement Due Date |
2008-02-19 |
Current Penalty |
300.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
02 |
|
|