Name: | TROY BOILER WORKS, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 07 Jan 1966 (59 years ago) |
Entity Number: | 194330 |
ZIP code: | 12180 |
County: | Rensselaer |
Place of Formation: | New York |
Address: | 2800 SEVENTH AVENUE, TROY, NY, United States, 12180 |
Principal Address: | 2800 SEVENTH AVE, TROY, NY, United States, 12180 |
Shares Details
Shares issued 5000
Share Par Value 0
Type NO PAR VALUE
Unique Entity ID | Expiration Date | Physical Address | Mailing Address | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KN2KAHKEE5L7 | 2024-12-20 | 2800 7TH AVE, TROY, NY, 12180, 1587, USA | 2800 SEVENTH AVE, TROY, NY, 12180, USA | |||||||||||||||||||||||||||||||||||||||||||||
|
URL | https://www.troyboiler.com/ |
Congressional District | 20 |
State/Country of Incorporation | NY, USA |
Activation Date | 2023-12-25 |
Initial Registration Date | 2003-09-02 |
Entity Start Date | 1966-01-07 |
Fiscal Year End Close Date | Dec 31 |
Service Classifications
NAICS Codes | 332114, 332312, 332313, 332410, 332420, 332996, 811310 |
Product and Service Codes | 4410, 4540, 4610, 9999, H349, J031, J044, J045, N045, Z1NZ, Z2AA |
Points of Contacts
Electronic Business | |
---|---|
Title | PRIMARY POC |
Name | DOMINIC GRASSO |
Role | BOOK KEEPER |
Address | TROY BOILER WORKS INC, 2800 SEVENTH AVENUE, TROY, NY, 12180, USA |
Government Business | |
---|---|
Title | PRIMARY POC |
Name | LOUIS E OKONSKI |
Role | PRESIDENT |
Address | TROY BOILER WORKS INC., 2800 SEVENTH AVENUE, TROY, NY, 12180, USA |
Past Performance | Information not Available |
---|
CAGE number | Status | Type | Established | CAGE Update Date | CAGE Expiration | SAM Expiration | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3HRA5 | Active | U.S./Canada Manufacturer | 2003-09-03 | 2024-11-20 | 2029-11-20 | 2025-11-14 | |||||||||||||||
|
POC | LOUIS E. OKONSKI |
Phone | +1 518-274-2650 |
Fax | +1 518-274-5454 |
Address | 2800 7TH AVE, TROY, NY, 12180 1587, UNITED STATES |
Ownership of Offeror Information
Highest Level Owner | Information not Available |
---|
Immediate Level Owner | Information not Available |
---|
List of Offerors (0) | Information not Available |
---|
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2023 | 141494252 | 2024-09-17 | TROY BOILER WORKS, INC. | 18 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2022 | 141494252 | 2023-09-19 | TROY BOILER WORKS, INC. | 16 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2021 | 141494252 | 2022-08-18 | TROY BOILER WORKS, INC. | 16 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2020 | 141494252 | 2021-09-14 | TROY BOILER WORKS, INC. | 16 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2019 | 141494252 | 2020-07-13 | TROY BOILER WORKS, INC. | 16 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2018 | 141494252 | 2019-08-16 | TROY BOILER WORKS, INC. | 14 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2017 | 141494252 | 2018-06-01 | TROY BOILER WORKS, INC. | 13 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2016 | 141494252 | 2017-07-13 | TROY BOILER WORKS, INC. | 13 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2015 | 141494252 | 2016-07-01 | TROY BOILER WORKS, INC. | 14 | |||||||||||||
|
||||||||||||||||||
TROY BOILER WORKS, INC. PROFIT SHARING PLAN | 2014 | 141494252 | 2015-07-06 | TROY BOILER WORKS, INC. | 12 | |||||||||||||
|
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 2800 SEVENTH AVENUE, TROY, NY, United States, 12180 |
Name | Role | Address |
---|---|---|
LOUIS E OKONSKI | Chief Executive Officer | 2 BROOKE COURT, CLIFTON PARK, NY, United States, 12065 |
Start date | End date | Type | Value |
---|---|---|---|
2024-06-25 | 2024-09-10 | Shares | Share type: PAR VALUE, Number of shares: 100, Par value: 4880 |
2024-06-25 | 2024-09-10 | Shares | Share type: NO PAR VALUE, Number of shares: 5000, Par value: 0 |
2024-03-20 | 2024-06-25 | Shares | Share type: NO PAR VALUE, Number of shares: 5000, Par value: 0 |
2024-03-20 | 2024-03-20 | Address | 2 BROOKE COURT, CLIFTON PARK, NY, 12065, USA (Type of address: Chief Executive Officer) |
2024-03-20 | 2024-03-20 | Address | 1149 MILLINGTON RD, NISKAYUNA, NY, 12309, USA (Type of address: Chief Executive Officer) |
2024-03-20 | 2024-06-25 | Shares | Share type: PAR VALUE, Number of shares: 100, Par value: 4880 |
2023-06-12 | 2024-03-20 | Shares | Share type: NO PAR VALUE, Number of shares: 5000, Par value: 0 |
2023-06-12 | 2024-03-20 | Shares | Share type: PAR VALUE, Number of shares: 100, Par value: 4880 |
2023-04-28 | 2023-06-12 | Shares | Share type: PAR VALUE, Number of shares: 100, Par value: 4880 |
2023-04-28 | 2023-06-12 | Shares | Share type: NO PAR VALUE, Number of shares: 5000, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
240320003522 | 2024-03-20 | BIENNIAL STATEMENT | 2024-03-20 |
220111000386 | 2022-01-11 | BIENNIAL STATEMENT | 2022-01-11 |
210324000116 | 2021-03-24 | CERTIFICATE OF CHANGE | 2021-03-24 |
200131060295 | 2020-01-31 | BIENNIAL STATEMENT | 2020-01-01 |
140128002108 | 2014-01-28 | BIENNIAL STATEMENT | 2014-01-01 |
120207002333 | 2012-02-07 | BIENNIAL STATEMENT | 2012-01-01 |
100126002083 | 2010-01-26 | BIENNIAL STATEMENT | 2010-01-01 |
080124002934 | 2008-01-24 | BIENNIAL STATEMENT | 2008-01-01 |
060206002872 | 2006-02-06 | BIENNIAL STATEMENT | 2006-01-01 |
031229002318 | 2003-12-29 | BIENNIAL STATEMENT | 2004-01-01 |
Contract Type | Award or IDV Flag | PIID | Start Date | Current End Date | Potential End Date | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PURCHASE ORDER | AWARD | W911PT09P0254 | 2009-04-03 | 2009-04-15 | 2009-04-15 | |||||||||||||||||||||||||||
|
Obligated Amount | 7200.00 |
Current Award Amount | 7200.00 |
Potential Award Amount | 7200.00 |
Description
Title | R/R LEAK TUBE BOILER#5 B-136 |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | Z111: MAINT-REP-ALT/OFFICE BLDGS |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, RENSSELAER, NEW YORK, 121801587 |
Unique Award Key | CONT_AWD_VA528C0691_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Description
Title | REPAIR BROKEN HOT WATER LINE |
NAICS Code | 236220: COMMERCIAL AND INSTITUTIONAL BUILDING CONSTRUCTION |
Product and Service Codes | Y141: CONSTRUCT/HOSPITALS & INFIRMARIES |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, 121801587 |
Unique Award Key | CONT_AWD_W911PT10P0083_9700_-NONE-_-NONE- |
Awarding Agency | Department of Defense |
Link | View Page |
Award Amounts
Obligated Amount | 4650.00 |
Current Award Amount | 4650.00 |
Potential Award Amount | 4650.00 |
Description
Title | FSC: Z242 NAME: REPAIR EMERGENCY LEAK IN B136 BOILER TUBE |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | Z242: MAINT-REP-ALT/HEATING & COOL PLANTS |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, RENSSELAER, NEW YORK, 121801587 |
Unique Award Key | CONT_AWD_V528Q1I831_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Description
Title | BOILER REPAIRS FOR ALBANY VAMC. |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | J045: MAINT-REP OF PLUMBING-HEATING EQ |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, 121801587 |
Unique Award Key | CONT_AWD_V528Q1I691_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Description
Title | BOILER REPAIR |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | H349: INSPECT SVCS/MAINT REPAIR SHOP EQ |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, 121801587 |
Unique Award Key | CONT_AWD_VA528Q1I555_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Description
Title | NONE |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | 4410: INDUSTRIAL BOILERS |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, 121801587 |
Unique Award Key | CONT_AWD_V528C13240_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Description
Title | HEATING COILS FOR KITCHEN HVAC UNIT |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | 4540: WASTE DISPOSAL EQUIPMENT |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, 121801587 |
Unique Award Key | CONT_AWD_W911PT12P0230_9700_-NONE-_-NONE- |
Awarding Agency | Department of Defense |
Link | View Page |
Award Amounts
Obligated Amount | 2719.40 |
Current Award Amount | 2719.40 |
Potential Award Amount | 2719.40 |
Description
Title | REPAIR BOILER TUBE |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | J099: MAINT/REPAIR/REBUILD OF EQUIPMENT- MISCELLANEOUS |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, RENSSELAER, NEW YORK, 121801587 |
Unique Award Key | CONT_AWD_W912PQ12C0002_9700_-NONE-_-NONE- |
Awarding Agency | Department of Defense |
Link | View Page |
Award Amounts
Obligated Amount | 6953.40 |
Current Award Amount | 6953.40 |
Potential Award Amount | 6953.40 |
Description
Title | EMERGENCY BOILER REPAIR |
NAICS Code | 332410: POWER BOILER AND HEAT EXCHANGER MANUFACTURING |
Product and Service Codes | Z2NB: REPAIR OR ALTERATION OF HEATING AND COOLING PLANTS |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Legacy DUNS | 002078715 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, RENSSELAER, NEW YORK, 121801587 |
Unique Award Key | CONT_AWD_36C24224P1751_3600_-NONE-_-NONE- |
Awarding Agency | Department of Veterans Affairs |
Link | View Page |
Award Amounts
Obligated Amount | 3994.00 |
Current Award Amount | 3994.00 |
Potential Award Amount | 3994.00 |
Description
Title | EMERGENCY BOILER REPAIR |
NAICS Code | 238220: PLUMBING, HEATING, AND AIR-CONDITIONING CONTRACTORS |
Product and Service Codes | J045: MAINT/REPAIR/REBUILD OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT |
Recipient Details
Recipient | TROY BOILER WORKS, INC |
UEI | KN2KAHKEE5L7 |
Recipient Address | UNITED STATES, 2800 7TH AVE, TROY, RENSSELAER, NEW YORK, 121801587 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347645517 | 0213100 | 2024-07-26 | 600 WOODS ROAD, GERMANTOWN, NY, 12526 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2191558 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261101 E01 |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(e)(1): All Class I, II, and III asbestos work was not conducted within regulated areas: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not establish a regulated area. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261101 F02 I |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(f)(2)(i): The employer failed to ensure that the exposure assessment was conducted in time to comply with requirements which are triggered by the exposure data or the lack of a negative exposure assessment: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not do an exposure assessment of the work area within the building. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261101 G01 I |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(g)(1)(i): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of vacuum cleaners equipped with high efficiency particulate air (HEPA) filters to collect all debris and dust containing asbestos containing material and presumed asbestos containing material: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not use engineering or work practice controls while the employees were dry sweeping and shoveling ACM. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261101 G01 II |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(g)(1)(ii): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of wet methods or wetting agents to control employee exposures during asbestos handling, mixing, removal, cutting, application and cleanup: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. Wet methods were not used when employees were dry sweeping and shoveling ACM. |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19261101 G01 III |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(g)(1)(iii): The employer did not use work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of prompt clean-up and disposal of wastes and debris contaminated with asbestos, in leak-tight containers: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not use leak-tight methods for collection and disposal of debris containing asbestos. |
Citation ID | 01003D |
Citaton Type | Serious |
Standard Cited | 19261101 G03 III |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(g)(3)(iii): The following work practices and engineering controls such as, but not limited to, dry sweeping can not be used for work related to asbestos or for work which disturbs ACM or PACM, regardless of measured levels of asbestos exposure or the results of initial exposure assessments: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employers' lack of engineering and work practice controls disturbed ACM. |
Citation ID | 01004A |
Citaton Type | Serious |
Standard Cited | 19261101 H01 IV |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(h)(1)(iv): Respirators were not used during all Class II and III asbestos jobs where the employer had not produced a negative-exposure assessment: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not provide respiratory protection while employees were dry sweeping and shoveling ACM. |
Citation ID | 01004B |
Citaton Type | Serious |
Standard Cited | 19261101 I01 |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos that exceed the time weighted average and/or excursion limit in 29 CFR 1926.1101(c) or for which a required negative exposure assessment was not produced: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not provide protective clothing for employees dry sweeping and shoveling ACM. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261101 J01 IV |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(j)(1)(iv): When food or beverages were consumed at a worksite involving Class I asbestos work, the employer did not provide a lunch area in which airborne concentrations of asbestos were below the permissible exposure limit and excursion limit: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not inform employees conducting dry sweeping and shoveling ACM of the locations and quantities of asbestos. |
Citation ID | 01006A |
Citaton Type | Serious |
Standard Cited | 19261101 K03 II B |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 7904.4 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(k)(3)(ii)(B): The employer did not inform employers of employees who worked and/or were working in adjacent areas of the location and quantity of asbestos containing material and/or presumed asbestos containing material present in the area: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not inform employees conducting dry sweeping and shoveling ACM of the locations and quantities of asbestos. |
Citation ID | 01006B |
Citaton Type | Serious |
Standard Cited | 19261101 K08 III |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(k)(8)(iii): The employer did not ensure that labels of bags or containers of protective clothing and equipment, scrap, waste, and debris containing asbestos fibers bear the following information: DANGER CONTAINS ASBESTOS FIBERS MAY CAUSE CANCER CAUSES DAMAGE TO LUNGS DO NOT BREATHE DUST AVOID CREATING DUST a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not label materials that contain ACM and/or PACM. |
Citation ID | 01006C |
Citaton Type | Serious |
Standard Cited | 19261101 K09 I |
Issuance Date | 2024-12-02 |
Abatement Due Date | 2024-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 11292.0 |
Final Order | 2025-02-03 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for each employee who was likely to be exposed in excess of the permissible exposure limit (PEL) and for each employee who performed Class I through IV asbestos operations: a) On or about 7/3/2024, throughout the boiler room, employees removed boiler, boiler components suspected of being potential asbestos containing materials (ACM), and asbestos debris including thermal system insulation (TSI) was also in the area. The employer did not train employees that were dry sweeping and shoveling materials that contain ACM and/or PACM. |
Inspection Type | FollowUp |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-11-20 |
Case Closed | 2014-12-19 |
Related Activity
Type | Inspection |
Activity Nr | 978780 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-05-30 |
Emphasis | N: AMPUTATE, P: AMPUTATE |
Case Closed | 2014-12-01 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100132 A |
Issuance Date | 2014-08-28 |
Abatement Due Date | 2014-09-10 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-09-22 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(a): Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) Workshop Floor - On or about August 21, 2014, employees were exposed to overhead struck-by hazards when loading steel on a truck without wearing hard hats. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100147 C04 I |
Issuance Date | 2014-08-28 |
Abatement Due Date | 2014-10-16 |
Current Penalty | 1750.0 |
Initial Penalty | 3500.0 |
Final Order | 2014-09-22 |
Nr Instances | 7 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) North Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for "The Niagara 1/2"/10ft shear" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. b) North Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Roundo PS 360 plate rolls" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. c) North Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Roundo PS 260 plate rolls" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. d) North Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Roundo R4 angle rolls" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. e) South Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Accurpress 400 ton press brake" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. f) South Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Niagara 200 ton press brake" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. g) South Shop - On or about May 30, 2014, specific procedures were not developed, documented and utilized for the "Akyapak 5/8"/10 plate rolls" which has 2 sources of energy consisting of hydraulic and electric energy for the maintenance employee who performs preventative maintenance on the equipment. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2014-08-28 |
Abatement Due Date | 2014-11-15 |
Current Penalty | 1750.0 |
Initial Penalty | 3500.0 |
Final Order | 2014-09-22 |
Nr Instances | 3 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Workshop Floor - On or prior to August 21, 2014, employees were exposed to caught-in hazards due to operating an Eagle Bending Machines (Model CPS 20) roll-bending machine without adequate machine guarding. b) Workshop Floor - On or prior to August 21, 2014, employees were exposed to caught-in hazards due to operating a Peddinghaus (Model 210 SUPER 20, Nr. 4412457773001) Ironworker machine without adequate machine guarding. c) Workshop Floor - On or prior to August 21, 2014, employees were exposed to caught-in hazards due to operating an Original Peddinghaus (Type: 210/13, Mach. No. 638) the smaller Ironworker machine without adequate machine guarding. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2008-09-16 |
Emphasis | S: POWERED IND VEHICLE, S: NOISE, N: SSTARG08, S: ELECTRICAL, S: AMPUTATIONS |
Case Closed | 2008-12-02 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C06 I |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Current Penalty | 700.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 02 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100179 J02 III |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Current Penalty | 700.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 02 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100179 J02 IV |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Current Penalty | 700.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 02 |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100179 J03 |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Current Penalty | 700.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 02 |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19100179 M01 |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Current Penalty | 700.0 |
Initial Penalty | 700.0 |
Nr Instances | 1 |
Nr Exposed | 20 |
Gravity | 02 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100132 D02 |
Issuance Date | 2008-10-06 |
Abatement Due Date | 2008-11-10 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 01 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2004-01-15 |
Emphasis | N: AMPUTATE |
Case Closed | 2004-03-19 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2004-02-06 |
Abatement Due Date | 2004-02-14 |
Current Penalty | 2500.0 |
Initial Penalty | 2500.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 1997-08-22 |
Emphasis | N: PWRPRESS |
Case Closed | 1997-12-22 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 1997-09-09 |
Abatement Due Date | 1997-11-14 |
Current Penalty | 625.0 |
Initial Penalty | 625.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 03 |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 1990-01-22 |
Case Closed | 1990-08-14 |
Related Activity
Type | Referral |
Activity Nr | 901362863 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 1990-02-08 |
Abatement Due Date | 1990-02-11 |
Current Penalty | 640.0 |
Initial Penalty | 640.0 |
Contest Date | 1990-03-02 |
Final Order | 1990-08-12 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 08 |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 1983-03-25 |
Case Closed | 1983-03-30 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Health |
Close Conference | 1983-03-28 |
Case Closed | 1982-09-25 |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100095 A |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-07-09 |
Current Penalty | 420.0 |
Initial Penalty | 420.0 |
Nr Instances | 30 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100095 L02 II |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-07-09 |
Nr Instances | 30 |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19100095 C |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-09-05 |
Nr Instances | 30 |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19100095 E01 |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-05-24 |
Nr Instances | 30 |
Citation ID | 02001C |
Citaton Type | Other |
Standard Cited | 19100095 N01 |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-09-05 |
Nr Instances | 30 |
Citation ID | 02001D |
Citaton Type | Other |
Standard Cited | 19100095 O01 |
Issuance Date | 1982-07-06 |
Abatement Due Date | 1982-07-09 |
Nr Instances | 30 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1979-05-02 |
Case Closed | 1979-08-08 |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100212 A02 |
Issuance Date | 1979-05-14 |
Abatement Due Date | 1979-05-30 |
Nr Instances | 2 |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100309 B 030015 |
Issuance Date | 1979-05-14 |
Abatement Due Date | 1979-05-30 |
Nr Instances | 1 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1977-03-11 |
Case Closed | 1977-04-14 |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100022 A02 |
Issuance Date | 1977-03-21 |
Abatement Due Date | 1977-03-24 |
Nr Instances | 1 |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100106 D02 I |
Issuance Date | 1977-03-21 |
Abatement Due Date | 1977-03-28 |
Nr Instances | 1 |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19100157 A05 |
Issuance Date | 1977-03-21 |
Abatement Due Date | 1977-03-24 |
Nr Instances | 2 |
Citation ID | 01004 |
Citaton Type | Other |
Standard Cited | 19100179 M01 |
Issuance Date | 1977-03-21 |
Abatement Due Date | 1977-03-28 |
Nr Instances | 1 |
Citation ID | 01005 |
Citaton Type | Other |
Standard Cited | 19100309 A 025045 |
Issuance Date | 1977-03-21 |
Abatement Due Date | 1977-03-24 |
Nr Instances | 1 |
Inspection Type | FollowUp |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1975-11-03 |
Case Closed | 1984-03-10 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1975-09-25 |
Case Closed | 1975-11-04 |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100309 A 025045 |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-16 |
Nr Instances | 3 |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100212 A03 II |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-30 |
Nr Instances | 3 |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19100219 D01 |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-30 |
Nr Instances | 2 |
Citation ID | 01004 |
Citaton Type | Other |
Standard Cited | 19100219 B01 I |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-30 |
Nr Instances | 1 |
Citation ID | 01005 |
Citaton Type | Other |
Standard Cited | 19100215 B03 |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-16 |
Nr Instances | 1 |
Citation ID | 01006 |
Citaton Type | Other |
Standard Cited | 19100252 A02 IV |
Issuance Date | 1975-09-29 |
Abatement Due Date | 1975-10-30 |
Nr Instances | 1 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3439668904 | 2021-04-28 | 0248 | PPS | 2800 7th Ave, Troy, NY, 12180-1519 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8719417301 | 2020-05-01 | 0248 | PPP | 2800 7th Avenue, Troy, NY, 12180 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Status | User ID | Name of Firm | Trade Name | UEI | Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Active | P0402429 | TROY BOILER WORKS, INC | - | KN2KAHKEE5L7 | 2800 7TH AVE, TROY, NY, 12180-1587 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Name | Louis Okonski |
Role | President |
SBA Federal Certifications
HUBZone Certified | No |
Women Owned Certified | No |
Women Owned Pending | No |
Economically Disadvantaged Women Owned Certified | No |
Economically Disadvantaged Women Owned Pending | No |
Veteran-Owned Small Business Certified | No |
Veteran-Owned Small Business Joint Venture | No |
Service-Disabled Veteran-Owned Small Business Certified | No |
Service-Disabled Veteran-Owned Small Business Joint Venture | No |
Bonding Levels
Description | Construction Bonding Level (per contract) |
Level | $0 |
Description | Construction Bonding Level (aggregate) |
Level | $0 |
Description | Service Bonding Level (per contract) |
Level | $0 |
Description | Service Bonding Level (aggregate) |
Level | $0 |
NAICS Codes with Size Determinations by NAICS
Primary | Yes |
Code | 332420 |
NAICS Code's Description | Metal Tank (Heavy Gauge) Manufacturing |
Buy Green | Yes |
Code | 332114 |
NAICS Code's Description | Custom Roll Forming |
Buy Green | Yes |
Code | 332312 |
NAICS Code's Description | Fabricated Structural Metal Manufacturing |
Buy Green | Yes |
Code | 332313 |
NAICS Code's Description | Plate Work Manufacturing |
Buy Green | Yes |
Code | 332410 |
NAICS Code's Description | Power Boiler and Heat Exchanger Manufacturing |
Buy Green | Yes |
Code | 332996 |
NAICS Code's Description | Fabricated Pipe and Pipe Fitting Manufacturing |
Buy Green | Yes |
Code | 811310 |
NAICS Code's Description | Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance |
Buy Green | Yes |
Export Profile (Trade Mission Online)
Exporter | No |
Export Business Activities | (none given) |
Exporting to | (none given) |
Desired Export Business Relationships | (none given) |
Description of Export Objective(s) | (none given) |
Performance History (References)
Name | Dept of Veterans Affairs |
Contract | 36C24218P3946 |
Start | 2018-09-20 |
End | 2018-10-05 |
Value | $8,275.00 |
Contact | Anthony Murray |
Name | Department of the Army |
Contract | W911PT15P0086 |
Start | 2015-04-21 |
End | 2015-04-30 |
Value | $3,957.94 |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1137053 | Interstate | 2023-04-12 | 29940 | 2022 | 3 | 3 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 4 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | .85 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 4 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 3 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 4.66 |
Number of inspections with at least one Driver Fitness BASIC violation | 1 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 1 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 1 |
Inspections
Unique report number of the inspection | SPWK082729 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2024-08-13 |
ID that indicates the level of inspection | Driver-Only |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 3 |
Number of Out-Of-Service violations related to Driver | 1 |
Number of Out-Of-Service violations related to vehicle | 0 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 1 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | DODG |
License plate of the main unit | 99476NE |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 3C7WRKBL3RG111916 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Total number of BASIC violations | 2 |
Number of Unsafe Driving BASIC violations | 1 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 1 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 0 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Unique report number of the inspection | SPB0402296 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2024-01-25 |
ID that indicates the level of inspection | Walk-around |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 2 |
Number of Out-Of-Service violations related to Driver | 0 |
Number of Out-Of-Service violations related to vehicle | 0 |
Number of violations related to Hazardous Materials | 2 |
Total number of Out-Of-Service violations | 0 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Hazardous substance labeling is required | N |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | DODG |
License plate of the main unit | 39962MK |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 3C7WRMBLXHG625952 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 0 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 0 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 0 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Unique report number of the inspection | 1L42000024 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2023-09-15 |
ID that indicates the level of inspection | Full |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 1 |
Number of Out-Of-Service violations related to Driver | 0 |
Number of Out-Of-Service violations related to vehicle | 0 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 0 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | DODG |
License plate of the main unit | 39962MK |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 3C7WRMBLXHG625952 |
Decal number of the main unit | 33073012 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 0 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 0 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 0 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Unique report number of the inspection | SPT0432728 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2023-01-03 |
ID that indicates the level of inspection | Walk-around |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 1 |
Number of Out-Of-Service violations related to Driver | 0 |
Number of Out-Of-Service violations related to vehicle | 2 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 2 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | DODG |
License plate of the main unit | 39962MK |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 3C7WRMBLXHG625952 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 3 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 0 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 3 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Violations
The date of the inspection | 2024-08-13 |
Code of the violation | 3922SLLS3 |
Name of the BASIC | Unsafe Driving |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 7 |
The time weight that is assigned to a violation | 3 |
The description of a violation | State/Local Laws - Speeding 11-14 miles per hour over the speed limit |
The description of the violation group | Speeding 3 |
The unit a violation is cited against | Driver |
The date of the inspection | 2024-08-13 |
Code of the violation | 39141A1FPC |
Name of the BASIC | Driver Fitness |
The violation is identified as Out-Of-Service violation | Y |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 2 |
The severity weight that is assigned to a violation | 1 |
The time weight that is assigned to a violation | 3 |
The description of a violation | Operating a property-carrying vehicle without possessing a valid medical certificate. Previously Cited on [DATE] |
The description of the violation group | Medical Certificate |
The unit a violation is cited against | Driver |
The date of the inspection | 2023-01-03 |
Code of the violation | 3939TS |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | Y |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 2 |
The severity weight that is assigned to a violation | 6 |
The time weight that is assigned to a violation | 1 |
The description of a violation | Inoperative turn signal |
The description of the violation group | Lighting |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2023-01-03 |
Code of the violation | 3939BRKLAMP |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 6 |
The time weight that is assigned to a violation | 1 |
The description of a violation | Inoperative Brake Lamps |
The description of the violation group | Lighting |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2023-01-03 |
Code of the violation | 39341 |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | Y |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 2 |
The severity weight that is assigned to a violation | 4 |
The time weight that is assigned to a violation | 1 |
The description of a violation | No or defective parking brake system on CMV |
The description of the violation group | Brakes All Others |
The unit a violation is cited against | Vehicle main unit |
Date of last update: 18 Mar 2025
Sources: New York Secretary of State