Search icon

TRADE-MARK CONSTRUCTION OF SYRACUSE, INC.

Company Details

Name: TRADE-MARK CONSTRUCTION OF SYRACUSE, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 08 Sep 1995 (30 years ago)
Date of dissolution: 29 Dec 1999
Entity Number: 1954502
ZIP code: 13205
County: Onondaga
Place of Formation: New York
Address: 615 RICHMOND AVENUE, SYRACUSE, NY, United States, 13205
Principal Address: 615 RICHMOND AVE, SYRACUSE, NY, United States, 13204

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 615 RICHMOND AVENUE, SYRACUSE, NY, United States, 13205

Chief Executive Officer

Name Role Address
NICHOLAS ANGARNAO Chief Executive Officer 615 RICHMOND AVE, SYRACUSE, NY, United States, 13204

Filings

Filing Number Date Filed Type Effective Date
DP-1454505 1999-12-29 DISSOLUTION BY PROCLAMATION 1999-12-29
971009002638 1997-10-09 BIENNIAL STATEMENT 1997-09-01
950908000009 1995-09-08 CERTIFICATE OF INCORPORATION 1995-09-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345432900 0215800 2021-07-22 226 CAROLINE AVENUE, SOLVAY, NY, 13209
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2021-07-22
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2022-01-12
Current Penalty 5200.0
Initial Penalty 10513.0
Final Order 2022-07-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 226 Caroline Avenue, Solvay, NY 13209, on or about 7/22/21: Workers were observed performing roofing work on a 6:12 pitch roof with a ground to eave height of 10 and 20 feet without fall protection of any kind.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-01-12
Current Penalty 3800.0
Initial Penalty 7510.0
Final Order 2022-07-18
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 226 Caroline Avenue, Solvay, NY 13209, on the back roof section, on or about 7/22/21: Workers used an aluminum extension ladder that did not extend at least 3 feet above the surface being accessed. b) 226 Caroline Avenue, Solvay, NY 13209, on the side porch roof section, on or about 7/22/21: Workers used an aluminum extension ladder that did not extend at least 3 feet above the surface being accessed.
344591433 0215800 2020-01-29 106 OXFORD ROAD, NEW HARTFORD, NY, 13413
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2020-01-29
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2023-06-02

Related Activity

Type Inspection
Activity Nr 1459148
Safety Yes
343737086 0215800 2019-01-24 709 NORTH SALINA STREET, SYRACUSE, NY, 13208
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2019-01-24
Emphasis L: FALL, P: FALL
Case Closed 2019-12-26

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2019-04-17
Current Penalty 1000.0
Initial Penalty 5304.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, in the basement, on or about 1/24/19: Workers were exposed to live electrical conductors where a service panel was unguarded/uncovered.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260403 B01 I
Issuance Date 2019-04-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, on or about 1/24/19: Workers used tools that were plugged into quad outlet boxes wired and used as extension cords, and not designed for that purpose.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2019-04-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 1/24/19: Workers were using power tools and appliances that were energized by connections to building power that was not GFI protected.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-04-17
Current Penalty 1000.0
Initial Penalty 5304.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At the jobsite, on or about 1/24/19: A worker was standing on the sill of a window opening without fall protection, and exposed to a 12 foot fall to the sidewalk. b) At the jobsite, on or about 1/24/19: Employees were working in close proximity to 5 unguarded window openings where the sills were 2 feet from the second floor deck and where workers were exposed to a 10 foot fall without fall protection.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2019-04-17
Current Penalty 500.0
Initial Penalty 3031.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: a) At the jobsite, on or about 1/24/19: Hole covers were not secured to the deck to prevent displacement.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2019-04-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-05-08
Final Order 2019-11-25
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) At the jobsite, on or about 1/24/19: Hole covers were not marked appropriately to indicate HOLE or COVER.

Date of last update: 14 Mar 2025