Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-02
|
Case Closed |
2014-02-03
|
Related Activity
Type |
Inspection |
Activity Nr |
608298 |
Safety |
Yes |
|
Type |
Accident |
Activity Nr |
535690 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2013-02-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees are exposed to struck by hazards. Worksite, 1001 Crooked Hill Rd. Brentwood NY - An amusement park ride operator was struck by the spinning bucket of a ride called The Scat, while standing below the operators platform; on or about 09/01/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2013-02-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative a) Worksite, 1001 Crooked Hill Rd. Brentwood NY - Employees perform maintenance functions on machines such as but not limited to the Scat, Merry-Go-Round, and Ferris Wheel. There was no Lockout Tagout program; on or about 09/01/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2013-02-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Worksite, 1001 Crooked Hill Rd. Brentwood NY - Employees performing maintenance functions on machines such as but not limited to the Scat, Merry-Go-Round, and Ferris Wheel, were not provided with documeted procedures to control hazardous energy; on or about 09/01/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2013-02-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) Worksite, 1001 Crooked Hill Rd. Brentwood NY - Employees performing maintenance functions on machines such as but not limited to the Scat, Merry-Go-Round, and Ferris Wheel, were not provided with a sufficient set of hardware to control all sources of energy; on or about 09/01/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2013-02-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Worksite, 1001 Crooked Hill Rd. Brentwood NY - Employees operating and performing maintenance functions on machines such as but not limited to the Scat, Merry-Go-Round, and Ferris Wheel, were not provided with all lockout-tagout training elements; on or about 09/01/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
|