Name: | EXTERIOR WORKS CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 15 Apr 1996 (29 years ago) |
Date of dissolution: | 31 Dec 2003 |
Entity Number: | 2020030 |
ZIP code: | 10566 |
County: | Westchester |
Place of Formation: | New York |
Address: | 24 KENT DRIVE, CORTLANDT MANOR, NY, United States, 10566 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 24 KENT DRIVE, CORTLANDT MANOR, NY, United States, 10566 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-1684409 | 2003-12-31 | DISSOLUTION BY PROCLAMATION | 2003-12-31 |
960415000366 | 1996-04-15 | CERTIFICATE OF INCORPORATION | 1996-04-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343613030 | 0216000 | 2018-11-20 | 185 KISCO AVE., MOUNT KISCO, NY, 10549 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2018-11-21 |
Current Penalty | 0.0 |
Initial Penalty | 3880.0 |
Contest Date | 2018-12-27 |
Final Order | 2019-09-19 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted: location: roof on or about: 11/20/18 a) Employees, engaged in roofing activities, were not provided with adequate means of fall protection. The employees were exposed to a fall of up to 18 feet 10 inches. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2018-11-21 |
Abatement Due Date | 2018-12-26 |
Current Penalty | 0.0 |
Initial Penalty | 3880.0 |
Contest Date | 2018-12-27 |
Final Order | 2019-09-19 |
Nr Instances | 5 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: location: roof on or about: 11/20/18 a) Employees, exposed to a fall hazard while engaged in roofing activities, were not provided with fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-11-21 |
Current Penalty | 1400.0 |
Initial Penalty | 2772.0 |
Contest Date | 2018-12-27 |
Final Order | 2019-09-19 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: location: north side of building on or about: 11/20/18 a) Employees were gaining access to and from the roof by using a ladder that extended only 1 foot above the roof. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |