Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2021-10-20
|
Emphasis |
P: HHHT50, L: HHHT50
|
Case Closed |
2022-11-04
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-04-20 |
Abatement Due Date |
2022-05-02 |
Current Penalty |
3108.0 |
Initial Penalty |
4144.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Timeless Frames, 1 Fisher Circle, Watertown, NY. Mill Area. On or about 10/20/21, an Authorized Employee was performing maintenance activities on a Unimak Gold 95 Molder (100 psi). The employer did not develop, document and utilize energy control procedures for the pneumatic source of energy for machines including, but not limited to the Unimak Gold 95 Molding Machine. b) Timeless Frames, 1 Fisher Circle, Watertown, NY. Mill Area. On or about 10/20/21, An Authorized Employee performing maintenance on the Unimak Gold 95 Molder (440 volt) did not utilize the procedures for the control of potentially hazardous energy (electrical). Abatement certification must be submitted for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2022-04-20 |
Abatement Due Date |
2022-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a) Timeless Frames, 1 Fisher Circle, Watertown, NY. Mill Area. On or about 10/20/2021, an Authorized Employee was performing maintenance on the Unimak Gold 95 Molder Machine powered by both electrical and pneumatic energy sources. The pneumatic energy source was not locked or tagged out prior to beginning maintenance activities on the machine. The employee(s) were not trained in the recognition of applicable energy sources (pneumatic), the type and magnitude of the energy available in the workplace and the methods and means necessary for the energy isolated. Abatement certification must be submitted for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 III B |
Issuance Date |
2022-04-20 |
Abatement Due Date |
2022-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: a) Timeless Frames, 1 Fisher Circle, Watertown, NY. Mill Area. On or about 10/20/21, Prior to providing maintenance on the Unimak Gold 95 Molder Machine, an Authorized Employee did not lock out the energy sources(s) per the Energy Control Procedure. The employee was not provided with retraining on the use of energy control procedures. Abatement certification must be submitted for this item. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2022-04-20 |
Abatement Due Date |
2022-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Timeless Frames, 1 Fisher Circle, Watertown, NY, Mill Area. On or about 10/20/21, an Authorized Employee was performing maintenance work including, but not limited to, changing blades on a Unimak Gold 95 Molder and did not affix a lockout device on the electrical energy source. Abatement certification must be submitted for this item. |
|
|