Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343611208 | 0216000 | 2018-11-09 | 233 S. MAIN ST, NEW CITY, NY, 10956 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1398187 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2018-11-23 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-02-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees. Location: 233 S. Main Street New City NY; left side of a gas station market a) On or about November 9, 2018, CSHO observed employees inside an excavation that was approximately 55ftx36ft and 13ft deep. There was no ladder or ramp in the trench excavation. There were no safe means of egress located inside of the trench. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 K01 |
Issuance Date | 2018-11-23 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-02-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. Location: 233 S. Main Street New City NY; left side of a gas station market. a) On or about November 9, 2018, employees were inside an excavation that was approximately 55ftx36ft and 13ft deep. CSHO observed multiple hazardous conditions - to include but not limited to no safe egress, no shoring, sloping or no trench box and no employee able to recognize hazards related to the excavation. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2018-11-23 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-02-08 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). Location: 233 S. Main Street New City NY; left side of a gas station market. a) On or about November 9, 2018, CSHO observed employees inside an excavation that was approximately 55ftx36ft and 13ft deep. The excavation was on the side of a gas station market. CSHO did not observed a trench box or shoring of the excavation. During employee interviews a trench box could not be reconstructed - shoring was done when excavation size was smaller. |