341318418
|
0213100
|
2016-03-11
|
1475 WASHINGTON AVE., ALBANY, NY, 12206
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-11
|
Emphasis |
L: FALL
|
Case Closed |
2017-06-21
|
Related Activity
Type |
Inspection |
Activity Nr |
1131849 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1131819 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1135278 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-04-08 |
Abatement Due Date |
2016-04-18 |
Current Penalty |
7000.0 |
Initial Penalty |
27500.0 |
Contest Date |
2016-05-03 |
Final Order |
2016-12-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Building roof - On or about March 11, 2016 and at times prior thereto, an employee was exposed to a fall from the flat roof of a 5 story apartment building. The employee was not wearing any personal fall protection. The 84 Lumber Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 955067, citation number 1, item number 1 and was affirmed as a final order on March 27, 2014, with respect to a workplace located at 8779 Georgetown Road, Cambridge, OH 43725. |
|
|
336418389
|
0215800
|
2012-09-06
|
FAIRFIELD INN - PARCEL 7 I-86 & ANN PAGE RD, HORSEHEADS, NY, 14845
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-09-06
|
Emphasis |
L: FALL, N: CTARGET
|
Case Closed |
2013-10-22
|
Related Activity
Type |
Inspection |
Activity Nr |
641778 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260034 A |
Issuance Date |
2013-03-04 |
Abatement Due Date |
2013-03-08 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Contest Date |
2013-03-27 |
Final Order |
2013-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(a): Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied: a) At the jobsite, on or about 9/6/12: The exits from the 2nd and 3rd floor were located in the middle of the building and required employees to pass through framed walls to access the area. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260034 B |
Issuance Date |
2013-03-04 |
Abatement Due Date |
2013-03-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-03-27 |
Final Order |
2013-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(b): Exits and access to exits were not marked by a readily visible sign: a) At the jobsite, on or about 9/6/12: The exit that was located in the center of the building was not marked to identify its location. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2013-03-04 |
Abatement Due Date |
2013-03-08 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Contest Date |
2013-03-27 |
Final Order |
2013-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) At the jobsite, on or about 9/6/12: Employees accessing the ladder to the 2nd floor of the building had to jump onto a window sill 36 inches above the grade. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2013-03-04 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Contest Date |
2013-03-27 |
Final Order |
2013-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately: a) At the jobsite, on or about 9/6/12: Employees were using a fiberglass extension ladder with cracked rails to access the 2nd floor work area. |
|
|
315248625
|
0213600
|
2011-01-25
|
12520 OLEAN ROAD, CHAFFEE, NY, 14030
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-01-25
|
Emphasis |
L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2011-03-09
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2011-02-09 |
Abatement Due Date |
2011-02-14 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100178 M05 I |
Issuance Date |
2011-02-09 |
Abatement Due Date |
2011-02-14 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
|
311137657
|
0214700
|
2009-05-20
|
1184 ROUTE 112, PORT JEFFERSON STATION, NY, 11776
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-05-20
|
Emphasis |
S: POWERED IND VEHICLE, S: FALL FROM HEIGHT, L: FORKLIFT, L: FALL
|
Case Closed |
2009-10-02
|
Related Activity
Type |
Referral |
Activity Nr |
200158111 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-28 |
Current Penalty |
1400.0 |
Initial Penalty |
1400.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-24 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-24 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100037 A04 |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-24 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100037 B02 |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-24 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
03 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 IIB |
Issuance Date |
2009-07-20 |
Abatement Due Date |
2009-07-30 |
Current Penalty |
800.0 |
Initial Penalty |
800.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
|