Inspection Type |
FollowUp
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-24
|
Case Closed |
2015-08-20
|
Related Activity
Type |
Inspection |
Activity Nr |
1073560 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1073552 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-07-14 |
Abatement Due Date |
2015-07-20 |
Current Penalty |
2625.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-07-29 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees who were working on the first floor of the residential building and retrieving tools and materials near unprotected sides were exposed to falls of approximately 10 ft.; on or about 6/24/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2015-07-14 |
Abatement Due Date |
2015-07-20 |
Current Penalty |
2625.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-07-29 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) Worksite: Employees carrying tools and materials from the ground floor to the first floor were using a walking/working surface that did not have intermediate structural members installed between the top edge of the guardrail system and the walking/working surface and were exposed to falls of approximately 10 ft.; on or about 6/24/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261052 C04 |
Issuance Date |
2015-07-14 |
Abatement Due Date |
2015-07-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-29 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a) Worksite: Employees carrying tools and materials from the ground floor to the first floor were using stairs that were not provided with intermediate structural members and were exposed to falls of up to and including approximately 10 ft.; on or about 6/24/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2015-07-14 |
Current Penalty |
1575.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Worksite: An employee was using the top and top step of a stepladder to do overhead framing work; on or about 6/24/15. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
|