343252490
|
0215800
|
2018-06-26
|
433 W. ONONDAGA STREET, SYRACUSE, NY, 13202
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-26
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2018-06-26
|
Related Activity
Type |
Inspection |
Activity Nr |
1297963 |
Safety |
Yes |
|
|
342979630
|
0215800
|
2018-02-28
|
433 W. ONONDAGA STREET, SYRACUSE, NY, 13202
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-28
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2018-06-26
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2018-03-26 |
Abatement Due Date |
2018-04-30 |
Current Penalty |
1663.5 |
Initial Penalty |
2218.0 |
Final Order |
2018-04-04 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) At the establishment, on or about 2/28/18: The employer did not ensure that operators of a Crown SX 3000 walkie stacker lift were formally trained and evaluated. Abatement certification must be submitted for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2018-03-26 |
Abatement Due Date |
2018-04-30 |
Current Penalty |
2772.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-04-04 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Digital Room, on or about 2/28/18: Point of operation on a Acme Champion stitcher was not guarded. b) Press Room, on or about 2/28/18: Ingoing nip points at the ink rollers on a Ryobi printing press, Model 3985, were not guarded. Abatement certification must be submitted for these items. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2018-03-26 |
Abatement Due Date |
2018-04-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-04 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the establishment, on or about 2/28/18: Where employees perform servicing, maintenance, set up, changeovers, etc. on various machinery or equipment, including, but not limited to printing presses, cutters, folders, compressors, etc., the employer had not established specific energy control procedures (lockout/tagout) to prevent the unexpected energizing, start up or release of stored energy of the equipment. Abatement certification must be submitted for this item. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100304 G05 |
Issuance Date |
2018-03-26 |
Abatement Due Date |
2018-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Press Room, on or about 2/28/18: A Polar Aire fan and a trouble light were not grounded in that the ground pins were missing from their plug ends. Abatement certification must be submitted for this item. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2018-03-26 |
Abatement Due Date |
2018-04-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Mail Room, on or about 2/28/18: Extension cord providing current to a strapper at the inkjet mailing equipment was being used as permanent wiring. Abatement certification must be submitted for this item. |
|
|
339547317
|
0215800
|
2014-01-15
|
214 SOLAR ST., SYRACUSE, NY, 13204
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-15
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2014-02-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-03-05 |
Current Penalty |
840.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Stitcher Area, on or about 1/15/14: Ingoing nip points and pinch points at the stitching heads and the conveying line on a Muller stitcher were not guarded. Abatement certification must be submitted for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-03-05 |
Current Penalty |
1050.0 |
Initial Penalty |
1500.0 |
Final Order |
2014-02-13 |
Nr Instances |
4 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) Inserter Area, on or about 1/15/14: Three sets of chains and sprockets driving a Phillipsburg inserter were not guarded. b) Stitcher Area, on or about 1/15/14: Chain and sprockets driving the conveyor on a Muller stitcher were not guarded. Abatement certification must be submitted for these items. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 B01 |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: a) Stitcher Area, on or about 1/15/14: Flexible cords and flexible conduit at the power feed panel were strung across the floor in front of the Muller stitcher creating a tripping hazard. Abatement certification must be submitted for this area. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100304 F01 IV |
Issuance Date |
2014-01-29 |
Abatement Due Date |
2014-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a) Plate Room, on or about 1/15/14: Two disconnect switches and a circuit breaker panel were not readily accessible in that cardboard boxes, five gallon pails and a vacuum cleaner was stored in front of the equipment. Abatement certification must be submitted for this item. |
|
|
312365240
|
0215800
|
2008-08-19
|
212 W. DIVISION STREET, SYRACUSE, NY, 13204
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-08-27
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2009-01-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100037 A03 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-09-09 |
Current Penalty |
243.75 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100219 B01 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Current Penalty |
243.75 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100219 B02 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Current Penalty |
243.75 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-09-09 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19100305 A02 IX |
Issuance Date |
2008-09-04 |
Abatement Due Date |
2008-10-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
|