Search icon

VERTEX STEEL CORP.

Company Details

Name: VERTEX STEEL CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 26 Sep 1996 (28 years ago)
Entity Number: 2069442
ZIP code: 11731
County: Suffolk
Place of Formation: New York
Address: 160 KETAY AVENUE SOUTH, EAST NORTHPORT, NY, United States, 11731
Principal Address: 160 KETAY AVE S, EAST NORTHPORT, NY, United States, 11731

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 160 KETAY AVENUE SOUTH, EAST NORTHPORT, NY, United States, 11731

Chief Executive Officer

Name Role Address
STACY COSMA Chief Executive Officer 160 KETAY DR S, E NORTHPORT, NY, United States, 11731

History

Start date End date Type Value
2004-12-17 2012-10-22 Address 160 KETAY AVE S, EAST NORTHPORT, NY, 11731, 5030, USA (Type of address: Chief Executive Officer)
1996-09-26 2002-08-05 Address 1283 TOWNLINE ROAD, NESCONSET, NY, 11767, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
121022002032 2012-10-22 BIENNIAL STATEMENT 2012-09-01
100924002433 2010-09-24 BIENNIAL STATEMENT 2010-09-01
080919002646 2008-09-19 BIENNIAL STATEMENT 2008-09-01
060915002514 2006-09-15 BIENNIAL STATEMENT 2006-09-01
041217002554 2004-12-17 BIENNIAL STATEMENT 2004-09-01
020805000743 2002-08-05 CERTIFICATE OF AMENDMENT 2002-08-05
960926000364 1996-09-26 CERTIFICATE OF INCORPORATION 1996-09-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339533994 0214700 2013-12-27 599 MIDDLE COUNTRY RD., SAINT JAMES, NY, 11780
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-12-27
Emphasis L: FALL
Case Closed 2019-03-15

Related Activity

Type Complaint
Activity Nr 866848
Safety Yes
Type Inspection
Activity Nr 980588
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-06-26
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-08-04
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 599 Jericho Tpke., St. James- Employees were not wearing head protection while exposed to being struck by overhead materials such as, but not limited to hand tools and connecting hardware being used by workers overhead; on or about 12/27/13. b) Worksite, 599 Jericho Tpke., St. James- Employees were not wearing head protection while exposed to struck-by hazards while working alongside a crane as they connected a beam to the crane hook in preparation for lift; on or about 12/27/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-06-26
Abatement Due Date 2014-07-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-08-04
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Worksite, 599 Jericho Tpke, St. James, NY- an employee was observed standing at the top of a concrete foundation approximately 12 feet above the ground below and was not protected from falling by the use of guardrail, safety net or personal fall arrest systems; on or about 12/27/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260760 B03
Issuance Date 2014-06-26
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-08-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(b)(3): Each connector working at heights over 15 and up to 30 feet above a lower level, was not provided with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or was not provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section. a) Worksite, 599 Jericho Tpke., St. James, NY- two employees were working at a height of approximately 24 feet above the ground below while engaged in connecting steel beams without the equipment necessary to be tied off; on or about 12/27/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260761 B02
Issuance Date 2014-06-26
Abatement Due Date 2014-07-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-08-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b)(1): The employer shall train each employee in the recognition and identification of fall hazards in the work area; a) Worksite, 599 Jericho Tpke, St. James, NY- Employees were working at a height of approximately 24 feet above the ground below while engaged in connecting steel beams and columns and were not provided with the equipment to tie off. The employees did not regonize the hazard in doing so; on or about 12/27/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 14 Mar 2025

Sources: New York Secretary of State