346660202
|
0215800
|
2023-04-26
|
217 LENOX AVENUE, ELMIRA HEIGHTS, NY, 14903
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-04-26
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2024-04-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2023-10-20 |
Abatement Due Date |
2023-11-16 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-11 |
Nr Instances |
1 |
Nr Exposed |
38 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Main entrance, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, on or about 4/26/2023, employees were prevented from using the main exit door without the use of a key. The door was locked and a key was inserted into the lock requiring it to be used to exit the building. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II |
Issuance Date |
2023-10-20 |
Abatement Due Date |
2023-11-16 |
Current Penalty |
4687.8 |
Initial Penalty |
7813.0 |
Final Order |
2023-11-11 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii): The lockout/tagout procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. a) Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 1, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy. b) Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 2, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy. c)Production area, Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, Omera Gasket Machine 3, on or about 4/26/2023. The written lockout/tagout procedures were not adequate for the Omera Gasket Machines, in that they did not clearly and specifically outline the specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Procedures did not include the control of all energy sources, including, but not limited to, pneumatic and hydraulic sources of energy. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2023-10-20 |
Abatement Due Date |
2023-11-16 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-11 |
Nr Instances |
2 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. a) Production Area (adjacent to welder #1), Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, on or about 4/26/2023: Employees exposed to pendant cords with metal receptacle boxes attached that are used to provide power to equipment. The receptacle is listed for permanent mounting only. b) Production Area (adjacent to welder #4), Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903, on or about 4/26/2023: Employees exposed to pendant cords with metal receptacle boxes attached that are used to provide power to equipment. These receptacle is listed for permanent mounting only. |
|
|
344084306
|
0215800
|
2019-06-14
|
217 LENOX AVENUE, ELMIRA HEIGHTS, NY, 14903
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-10-30
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2020-01-06
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 I |
Issuance Date |
2019-11-04 |
Abatement Due Date |
2019-11-12 |
Current Penalty |
4068.0 |
Initial Penalty |
6630.0 |
Final Order |
2019-11-15 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use the types of personal protective equipment (PPE) that would protect the affected employee(s) from the hazards identified in the hazard assessment. a) Spot Welding, on or about 6/14/19: The employer did not have each affected employee use arm protection to protect them from the hazards of flying sparks. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100133 A03 |
Issuance Date |
2019-11-04 |
Abatement Due Date |
2019-11-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-11-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee, who wore prescription lenses while engaged in operations that involved eye hazards, used protection that incorporated the prescription in its design, or wore eye protection over the prescription glasses or protective lenses with side shields. a) Spot Welding Areas, on or about 6/14/19: The employer did not ensure that employees who were spot welding wore safety eyewear that incorporated prescription lenses in its design, or that they wore safety eyewear that fit over their prescription glasses or protective lenses with side shields. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2019-11-04 |
Current Penalty |
2760.0 |
Initial Penalty |
4508.0 |
Final Order |
2019-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Assembly Room, on or about 6/10/19: Rotary cutter did not have a guard over the belt and pulley drive. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 |
Issuance Date |
2019-11-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-11-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to the requirements specified in 29 CFR1910.219 (m) and (o). a) Assembly Room, on or about 6/10/19: Rotary cutter did not have a guard over the belt and pulley drive. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A03 II |
Issuance Date |
2019-11-04 |
Current Penalty |
7172.0 |
Initial Penalty |
11669.0 |
Final Order |
2019-11-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Production Area, on or about 6/14/19: #3 Omera gasket assembly machine was not provided with adequate point of operation guarding in that the light curtain provided was not working and allowed the operator to reach into the machine while operating. Stamped Fittings, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 989831, citation number 2, item number 1b and was affirmed as a final order on 9/25/14, with respect to a workplace located at 217 Lenox Avenue, Elmira Heights, NY. |
|
|
339898314
|
0215800
|
2014-08-13
|
217 LENOX AVENUE, ELMIRA HEIGHTS, NY, 14903
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-08-13
|
Emphasis |
N: AMPUTATE, N: SSTARG14, P: SSTARG14
|
Case Closed |
2016-03-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-20 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-09-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Warehouse, on or about 8/13/14: Employees were not able to use the exit door provided in that the door was locked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-10-10 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-09-25 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Press Department, on or about 8/13/14: Pendant cords with metal receptacle boxes attached were used to provide power to equipment. These metal boxes are listed for permanent mounting only. |
|
Citation ID |
02001A |
Citaton Type |
Repeat |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-10-23 |
Current Penalty |
3360.0 |
Initial Penalty |
5600.0 |
Final Order |
2014-09-25 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Area, on or about 8/13/14: (2) Two Omera gasket assembly machines were not provided with guarding to prevent contact with the rotating spindle. Stamped Fittings, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 314348145, citation number 1, item number 2, and was affirmed as a final order on 3/01/2011, with respect to a workplace located at 217 Lenox Avenue, Elmira Heights. NY. |
|
Citation ID |
02001B |
Citaton Type |
Repeat |
Standard Cited |
19100212 A03 II |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-10-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-25 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Assembly Department, on or about 8/13/14: Western Arctronics spot welder was not provided with point of operation guarding. b) Welding Department, on or about 8/13/14: Chicago riveter was not provided with point of operation guarding. c) Assembly Department, on or about 8/13/14: Gorelock machine was not provided with point of operation guarding. d) Production Area, on or about 8/13/14: (2) Two Omera gasket assembly machines were not provided with point of operation guarding. Stamped Fittings, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii) which was contained in OSHA inspection number 314348145, citation number 1, item number 3 and was affirmed as a final order on 3/01/2011, with respect to a workplace located at 217 Lenox Avenue, Elmira Heights, NY. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19100217 E01 I |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-20 |
Current Penalty |
84.0 |
Initial Penalty |
140.0 |
Final Order |
2014-09-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to insure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) Stamped Fittings, Inc., on or about 8/13/14: Records of mechanical power press inspection and maintenance were not maintained for presses such as but not limited to: 30 Ton Rousselle, 150 Ton CMC Clearin and 15 Ton Rousselle. |
|
|
307688366
|
0215800
|
2005-01-04
|
217 LENOX AVE, ELMIRA HEIGHTS, NY, 14903
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2005-01-04
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2005-02-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2005-01-24 |
Abatement Due Date |
2005-01-27 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2005-01-24 |
Abatement Due Date |
2005-01-27 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100217 B04 I |
Issuance Date |
2005-01-24 |
Abatement Due Date |
2005-01-27 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100217 C01 I |
Issuance Date |
2005-01-24 |
Abatement Due Date |
2005-01-27 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2005-01-24 |
Abatement Due Date |
2005-01-27 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
01 |
|
|