Search icon

HADLEY STORAGE, INC.

Company Details

Name: HADLEY STORAGE, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 18 Dec 1967 (57 years ago)
Entity Number: 217324
ZIP code: 14207
County: Erie
Place of Formation: New York
Address: 1700 ELMWOOD AVENUE, BUFFALO, NY, United States, 14207

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 1700 ELMWOOD AVENUE, BUFFALO, NY, United States, 14207

History

Start date End date Type Value
1967-12-18 2006-05-15 Address 631 FARGO AVE, BUFFALO, NY, 14213, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
060515000099 2006-05-15 CERTIFICATE OF AMENDMENT 2006-05-15
C223302-2 1995-05-24 ASSUMED NAME CORP INITIAL FILING 1995-05-24
654419-6 1967-12-18 CERTIFICATE OF INCORPORATION 1967-12-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339514549 0213600 2013-12-10 1700 ELMWOOD AVENUE, BUFFALO, NY, 14207
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-01-02
Emphasis N: SSTARG12, P: SSTARG12
Case Closed 2014-03-05

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100107 B03
Issuance Date 2014-01-02
Abatement Due Date 2014-01-13
Current Penalty 0.0
Initial Penalty 2380.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(3): Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues: a) On or about 12/10/13, in the Finish Shop, Employer used combustible cardboard sheets on the floors and on working tables inside two spray-booths to facilitate cleaning tasks. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Other
Standard Cited 19100107 B09
Issuance Date 2014-01-02
Abatement Due Date 2014-02-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) On or about 12/10/13, in the Finish Shop, wood pieces, lockers, clothing and other materials were stored behind the two spray-booths' walls. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2014-01-02
Abatement Due Date 2014-02-02
Current Penalty 2000.0
Initial Penalty 2380.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) On or about 12/10/2013, in the Finish Shop, employees sprayed parts with paints, solvents and other flammable liquids inside spray-booths. They used tight-fitting facepiece respirators and the last respirators' fit testing were conducted on 01/31/2011. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2014-01-02
Abatement Due Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 2975.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 12/10/13, in the establishment, Employer did not perform periodic inspections of their machine-specific lockout/tagout (LOTO) procedures to evaluate their energy control program's accuracy and authorized employees proficiency in the application of LOTO procedures for machines such as, but not limited to: CNC Router, Band Saws, Cut-off Saws, Panel Saws, Table Saws, Straight Line Rip Saws. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2014-01-02
Abatement Due Date 2014-03-03
Current Penalty 2000.0
Initial Penalty 2975.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about 12/10/13, in the second floor/set up room, while changing a saw blade, a lockout/tagout device was not affixed to the electrical disconnect switch of a Delta RT 40 Table Saw. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01005
Citaton Type Serious
Standard Cited 19100157 G02
Issuance Date 2014-01-02
Abatement Due Date 2014-02-02
Current Penalty 1000.0
Initial Penalty 1785.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 45
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) On or about 12/10/13, in the establishment, Employer did not provide an educational program/training related to the use of fire extinguishers and fire hazards and employees were expected to use portable fire extinguishers for small fires. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01006
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-01-02
Abatement Due Date 2014-02-02
Current Penalty 2000.0
Initial Penalty 2975.0
Final Order 2014-01-27
Nr Instances 3
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by saw blades: a) On or about 12/10/13, in the model maker wood shop area/second floor, a Rockwell/Delta Vertical Band Saw's adjustable guard did not cover the non-working part of the blade completely and under the table the non-working part of the blade did not have a guard. b) On or about 12/10/13, in the metal shop/first floor, a DoAll Model C8 Horizontal Band Saw did not have guards to cover the non-working part of the blade. c) On or about 12/10/13, in the metal shop/first floor, a Vertical Band Saw's guard under the table did not cover the non-working part of the blade completely. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01007
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2014-01-02
Abatement Due Date 2014-02-02
Current Penalty 1000.0
Initial Penalty 1785.0
Final Order 2014-01-27
Nr Instances 2
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about 12/10/13, in the metal shop areas, a Skilsaw Bench Grinder did not have a tongue guard and the distance between the wheel and the end of the safety guard peripheral member was approximately 1.5 inches. b) On or about 12/10/13, in the metal shop areas, a Craftsman Bench Grinder's tongue guards were adjusted to approximately 1/2 inch. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01008
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2014-01-02
Abatement Due Date 2014-01-13
Current Penalty 1000.0
Initial Penalty 1785.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 12/10/13, in the second floor/set up room, an extension cord was used to energize a DeWalt Panel Saw (120 volts) instead of using fixed wiring. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2014-01-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-27
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained: a) On or about 12/10/13, in the Finish Shop Areas, spraybooths' manometers were not functional. NO ABATEMENT CERTIFICATION REQUIRED