340650019
|
0213600
|
2015-05-22
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14623
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-19
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2016-09-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2015-12-06 |
Current Penalty |
4400.0 |
Initial Penalty |
4400.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye protection when exposed to eye hazards from flying particles, liquid chemicals: a) On or about 05/28/15 in the Exhaust Muffler Hanger Department; employer failed to protect employees involved in disconnecting the liquid hardener spray unit from being sprayed in the eyes with a flammable liquid and eye irritant when safety glasses were used as eye protection instead of goggles as described in the SDS for Mineral Spirits Odorless. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2015-12-06 |
Current Penalty |
5500.0 |
Initial Penalty |
5500.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 05/28/15 in the Exhaust Hanger Department; employer failed to ensure the operator of the horizontal Muffler Hanger Winder applied a lock on the disconnect switch and the main air prior to performing service and maintenance on this machine, such as, changing of the spool and associated needle threading, as described in portions of the Muffler Hanger Winder SF 052 Energy Control procedure dated 11/30/2009, exposing them to puncture and caught between hazards. b) On or about 05/28/15 in the Exhaust Hanger Department; employer failed to ensure the operator of the vertical Muffler Hanger Machine applied a lock on the Machine Disconnect Switch and main air supply prior to performing service and maintenance on this machine, such as, changing the spool of winding and the associated needle threading, as described in the Muffler Hanger Machine SF052 Energy Control procedure dated 10/26/12, exposing them to puncture and caught between hazards. c) On or about 05/28/15 in the Exhaust Hanger Department; employer failed to ensure the operator of the Muffler Hanger Cutter applied a lock on the local disconnect switch and main air supply prior to performing service and maintenance on this machine, such as, changing the cutting blades, as described in the Muffler Hanger Cutter SF052 Energy Control procedure dated 11/30/09, exposing them to laceration hazards. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2016-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
5500.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 05/28/15 throughout the production areas; employer failed to protect employees involved in service and maintenance activities from amputation and caught between hazards, when periodic inspections of the energy control procedures of machines, such as but not limited to Muffler Hanger Winder, Muffler Hanger Cutter, Muffler Hanger Machine (vertical), were not conducted to verify accuracy of the procedures and compliance by Authorized employees. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2015-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
7000.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by the ingoing nip point of the two rollers: a) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the Pull Roll from being able to access the ingoing nip point created by the two rollers, when the opening on the guarding device was 1.25 inches and the distance to the point of operation was 2 inches exposing them to caught between hazards. ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100212 A02 |
Issuance Date |
2015-11-05 |
Current Penalty |
7000.0 |
Initial Penalty |
7000.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) On or about 05/08/15 in the Textile Department; employer failed to protect employees who operate the core cutting machine ( #689452-G2 ), from being able to access the cutting blades, when one of the guards was missing an attachment device which allow the guard to be repositioned allowing access to the point of operation and exposure to an amputation hazard. NO ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100217 C02 I A |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2015-12-06 |
Current Penalty |
7000.0 |
Initial Penalty |
7000.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s); a) On or about 05/28/15 in the Lectracon Department; employer failed to protect employees who operated the Benchmaster mechanical power press from being able to reach the point of operation ( caught between hazard) when the configuration of the guarding device on the operator's left side of the machine ( 5.5 inches at the widest point at a distance of 4 inches from the point of operation) exposing them to an amputation hazard. ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01007 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 I |
Issuance Date |
2015-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
4400.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 05/28/15 in the Textile Department; employer failed to protect employees against contact with energized electrical conductor when the wiring of the safety switch was visible and pulled away from the bushing on the Hot Melt Winder machine. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2015-11-05 |
Abatement Due Date |
2015-12-06 |
Current Penalty |
35000.0 |
Initial Penalty |
70000.0 |
Contest Date |
2015-11-25 |
Final Order |
2016-03-14 |
Nr Instances |
6 |
Nr Exposed |
12 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): 8) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the Core Cutter machine ( # 689452-G2 ) from being able to access the point of operation ( sharp cutting blades and tension rollers ), when the diameter of the opening on the guarding device was 4.5 inches and the distance to the point of operation was 6.5 inches exposing them to an amputation hazard. 9) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the Core Cutter machine ( # 689452-G2 ) from being able reach into the opening on the side of the guard opposite the operator controls and access the point of operation (sharp cutting blades) exposing them to an amputation hazard. The opening on guarding device was 7 inches wide and 11.25 inches from the point of operation ( cutting blades and rotating shaft ). 10) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the S&P Cutter from being able to access the point of operation (cutting blades) during operation when the diameter of the opening on the guarding device was 4.25 inches and the distance to the point of operation was 5.75 inches, exposing them to an amputation hazard. 11) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the S&P Cutter from being able to access the point of operation (cutting blades and the tension rollers) when the opening on the back side of the guarding device was 6 wide inches and the distance to the point of operation was 7 inches and 3 inches from the tension roller, exposing them to an amputation hazard. 12) On or about 05/28/15 in the Textile Department; employer failed to protect employees who were assigned to operate the stapler for the IBM Brush ( machine # 689358 - G2 ) from being able to access the point of operation (stapler head), when the diameter of the opening on the guarding device was 3 inches and the distance to the point of operation was 1.5 inches, exposing them to puncture hazards. ABATEMENT DOCUMENTATION REQUIRED Schlegel Systems Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1910.212 (a) (1) which was contained in OSHA inspection number 620798 Citation Number 2, Item Number 1 and was affirmed as a final order on May 10, 2013, with respect to a workplace located at 1555 Jefferson Road, Rochester, New York 14692. |
|
|
336523980
|
0213600
|
2012-09-27
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-10-23
|
Case Closed |
2013-07-15
|
Related Activity
Type |
Referral |
Activity Nr |
566090 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101030 C01 II B |
Issuance Date |
2012-10-25 |
Abatement Due Date |
2012-11-14 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Contest Date |
2012-11-20 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
24 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(ii)(B): The employer's Exposure Control Plan did not include the schedule and method of implementation for 29 CFR 1910.1030(f), Hepatitis B Vaccination and Post-Exposure Evaluation and Follow-up: (a) On or about 9/10/2012 - The employer's Exposure Control Plan did not include the schedule and method of implementation for 29 CFR 1910.1030(f), Hepatitis B Vaccination and Post-Exposure Evaluation and Follow-up. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101030 C01 IV |
Issuance Date |
2012-10-25 |
Abatement Due Date |
2012-11-14 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Contest Date |
2012-11-20 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
24 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually: (a) On or about 9/11/2012, the Exposure Control Plan was not reviewed and updated at least annually. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101030 G02 I |
Issuance Date |
2012-10-25 |
Abatement Due Date |
2012-11-26 |
Current Penalty |
1500.0 |
Initial Penalty |
5000.0 |
Contest Date |
2012-11-20 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program: (a) On or about 09/10/2012 - the employer did not ensure that each employee with occupational exposure participated in a training program. |
|
|
336207980
|
0213600
|
2012-09-11
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-24
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2013-07-19
|
Related Activity
Type |
Referral |
Activity Nr |
548571 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I B |
Issuance Date |
2012-10-01 |
Current Penalty |
0.0 |
Initial Penalty |
7000.0 |
Contest Date |
2012-10-24 |
Final Order |
2013-05-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) On or about 9/10/11 in the Plastics Department; temporary employee(s) who were working as Tenders on Line #11, in and around the Conair Gatto cutter#73050, when the cutter experienced a jam. Employer did not instruct employees about the purpose and use of the SF 052 Energy Control procedure when jams occur. No Abatement Documentation |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A02 |
Issuance Date |
2012-10-01 |
Current Penalty |
0.0 |
Initial Penalty |
7000.0 |
Contest Date |
2012-10-24 |
Final Order |
2013-05-10 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) On or about 9/11/12 in the Plastics Department; employer installed PVC tube ( 3 inches x 5 inches ), on the outlet and inlet side of the Conair brand Gatto cutter, was not secured to the metal collar allowing access to the moving cutting blade. No Abatement Documentation |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A03 II |
Issuance Date |
2012-10-01 |
Abatement Due Date |
2012-10-23 |
Current Penalty |
7000.0 |
Initial Penalty |
35000.0 |
Contest Date |
2012-10-24 |
Final Order |
2013-05-10 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
SCHLEGEL SYSTEMS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 310651104, CITATION NO. 1, ITEM NO. 9 , AND WAS AFFIRMED AS A FINAL ORDER ON 01/22/2008, WITH RESPECT TO A WORKPLACE LOCATED AT 1555 JEFFERSON ROAD, ROCHESTER, NEW YORK,14692 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation on the Conair brand Gatto cutter exposing them to contact with hazard: b) On or about 9/11/12 in the Plastics Department - Line # 3; the plexiglass tube ( 2 inches x 3 3/4 inches ) on the outlet side of the Conair brand Gatto cutter, did not protect employee(s) from accessing the rotating cutting blade. Abatement Documentation |
|
|
314584939
|
0213600
|
2010-06-24
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
FollowUp
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-06-24
|
Case Closed |
2010-06-29
|
Related Activity
Type |
Inspection |
Activity Nr |
310651104 |
|
|
310859509
|
0213600
|
2007-03-29
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2007-07-02
|
Case Closed |
2007-07-06
|
Related Activity
Type |
Referral |
Activity Nr |
201336617 |
Health |
Yes |
|
|
310942594
|
0213600
|
2007-03-14
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2007-03-14
|
Case Closed |
2007-03-14
|
Related Activity
Type |
Referral |
Activity Nr |
201336617 |
Safety |
Yes |
Health |
Yes |
|
|
310651104
|
0213600
|
2007-01-08
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2007-03-29
|
Emphasis |
N: SSTARG06
|
Case Closed |
2010-06-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100120 Q03 V |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
2975.0 |
Initial Penalty |
2975.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100120 Q03 VII |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Initial Penalty |
2975.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100132 B |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3333.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100137 B02 VIII |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3333.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3333.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
5 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 IA |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3333.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
5 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3333.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
5 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100147 F03 I |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-04-23 |
Current Penalty |
1700.0 |
Initial Penalty |
1700.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Current Penalty |
3335.0 |
Initial Penalty |
5000.0 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100120 F07 IA |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-04-09 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 H03 IB |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-04-17 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100134 H03 IVA |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-04-17 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100147 C05 II |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100333 B02 I |
Issuance Date |
2007-04-04 |
Abatement Due Date |
2007-05-07 |
Contest Date |
2007-04-26 |
Final Order |
2008-01-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
308044155
|
0213600
|
2004-09-23
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2004-11-29
|
Case Closed |
2004-12-07
|
Related Activity
Type |
Complaint |
Activity Nr |
204895965 |
Health |
Yes |
|
|
308000579
|
0213600
|
2004-08-10
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2004-11-12
|
Case Closed |
2005-12-30
|
Related Activity
Type |
Complaint |
Activity Nr |
204895551 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2004-11-23 |
Abatement Due Date |
2004-11-26 |
Current Penalty |
2000.0 |
Initial Penalty |
4500.0 |
Contest Date |
2004-12-17 |
Final Order |
2005-12-05 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
Hazard |
CRUSHING |
|
|
108660846
|
0213600
|
1997-04-09
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1997-04-09
|
Case Closed |
1997-04-09
|
Related Activity
Type |
Complaint |
Activity Nr |
201318326 |
Safety |
Yes |
Health |
Yes |
|
|
106912959
|
0213600
|
1990-04-11
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Health |
Close Conference |
1990-06-12 |
Case Closed |
1990-07-02 |
Related Activity
Type |
Complaint |
Activity Nr |
73064974 |
Health |
Yes |
|
|
107650301
|
0213600
|
1989-12-06
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1990-01-03 |
Case Closed |
1990-02-01 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-02-12 |
Current Penalty |
310.0 |
Initial Penalty |
560.0 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
07 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100157 G01 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-02-12 |
Initial Penalty |
480.0 |
Nr Instances |
1 |
Nr Exposed |
350 |
Gravity |
06 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Current Penalty |
300.0 |
Initial Penalty |
480.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
06 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-02-12 |
Current Penalty |
310.0 |
Initial Penalty |
560.0 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
07 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Current Penalty |
300.0 |
Initial Penalty |
480.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
06 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Nr Instances |
1 |
Nr Exposed |
5 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Current Penalty |
300.0 |
Initial Penalty |
480.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
06 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Nr Instances |
1 |
Nr Exposed |
5 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100304 A02 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-18 |
Current Penalty |
300.0 |
Initial Penalty |
480.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
06 |
|
Citation ID |
01008A |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Initial Penalty |
400.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01008B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-02-12 |
Current Penalty |
380.0 |
Initial Penalty |
640.0 |
Nr Instances |
2 |
Nr Exposed |
393 |
Gravity |
08 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-16 |
Nr Instances |
1 |
Nr Exposed |
20 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
1990-01-08 |
Abatement Due Date |
1990-01-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
|
100805985
|
0213600
|
1988-01-28
|
1555 JEFFERSON ROAD, ROCHESTER, NY, 14692
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Health |
Close Conference |
1988-01-28 |
Case Closed |
1988-01-28 |
Related Activity
Type |
Complaint |
Activity Nr |
71860043 |
Health |
Yes |
|
|