Search icon

THE EXECUTIVE GROUP, INC.

Company Details

Name: THE EXECUTIVE GROUP, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Jan 1998 (27 years ago)
Entity Number: 2213443
ZIP code: 11725
County: Nassau
Place of Formation: New York
Address: 109 SHINBONE LANE, COMMACK, NY, United States, 11725

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 109 SHINBONE LANE, COMMACK, NY, United States, 11725

Chief Executive Officer

Name Role Address
LESLIE LEVITT RASCHELLA Chief Executive Officer 30 JERICHO TPKE 3285, COMMACK, NY, United States, 11725

History

Start date End date Type Value
2000-02-09 2006-02-17 Address 109 SHINBONE LN, COMMACK, NY, 11725, USA (Type of address: Chief Executive Officer)
2000-02-09 2006-02-17 Address 30 JERICHO TPKE, 285, COMMACK, NY, 11725, USA (Type of address: Principal Executive Office)

Filings

Filing Number Date Filed Type Effective Date
060217002514 2006-02-17 BIENNIAL STATEMENT 2006-01-01
000209002353 2000-02-09 BIENNIAL STATEMENT 2000-01-01
980102000178 1998-01-02 CERTIFICATE OF INCORPORATION 1998-01-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343934261 0213100 2019-04-16 50 PARK STREET, AMSTERDAM, NY, 12010
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2019-04-16
Case Closed 2022-11-14

Related Activity

Type Complaint
Activity Nr 1445550
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100106 E02 II B 2
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 3447.6
Initial Penalty 5304.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of Category 2, 3 or 4 flammable liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons: a). On or about 4/16/19, on site in the spray paint area, approximately 217 gallons of Category 2 flammable liquids were stored outside of a storage cabinet.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 3447.6
Initial Penalty 5304.0
Final Order 2019-11-14
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a). On or about, 4/16/19, on site, in spray paint area, for the employee required to don a 3M 1/2 mask respirator while conducting spray painting tasks in a spray booth. The employer did not implement a written respiratory program to include fit tests, medical evaluations, and training. b). On or about, 4/16/19, on site, in spray paint area, for the employee required to don a 3M 8210 N95 while conducting wood cutting tasks. The employer did not implement a written respiratory program to include fit tests, medical evaluations, and training.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-14
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. a). On or about, 4/16/19, on site, in the spray paint area, for the employee required to don a 3M 1/2 mask respirator while conducting spray painting tasks in a spray booth. The employer did not implement a written respiration program to include medical evaluations. b). On or about, 4/16/19, on site, in the spray paint area, for the employee required to don a 3M 8210 N95 while conducting wood cutting tasks. The employer did not implement a written respiration program to include medical evaluations.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 K
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-14
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a). On or about, 4/16/19, on site, for the employee required to don a 3M 1/2 mask respirator while conducting spray painting tasks in a spray booth. The employer did not implement a written respiration program to include training. b). On or about, 4/16/19, on site, for the employee required to don a 3M 8210 N95 while conducting wood cutting tasks. The employer did not implement a written respiration program to include training.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 3447.6
Initial Penalty 5304.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a). On or about, 4/16/19, on site, for employees using corrosives such as, but not limited to, M.L Campbell MagnaMax Pre-Catalyzed Lacquer. The employer did not provide an eye wash and shower on site.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 4309.5
Initial Penalty 6630.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a). On or about 4/16/19, on site, for employees using a Saw Stop table saw without a guard. The employees use the table saw daily.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 4309.5
Initial Penalty 6630.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a). On or about 4/16/19, for employees handling spray paint products such as M.L Campbell MagnaMax Pre-Catalyzed Lacquer, M.L Campbell MagnaSand Sealer M.L Campbell WashThinner, and M.L. Campbell Industrial Colorant to paint wood products. M.L Campbell MagnaMax Pre-Catalyzed Lacquer contains chemicals, such as, but not limited to, formaldehyde. The employer did not implement a hazard communication program to include a written program and training.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a). On or about 4/16/19, for employees handling spray paint products such as M.L Campbell MagnaMax Pre-Catalyzed Lacquer, M.L Campbell MagnaSand Sealer M.L Campbell WashThinner, and M.L. Campbell Industrial Colorant to paint wood products. M.L Campbell MagnaMax Pre-Catalyzed Lacquer contains chemicals, such as, but not limited to, formaldehyde. The employer did not implement a hazard communication program to include training.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 F02
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-11-14
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a). On or about, 4/16/19, on site, for the employee required to don a 3M 1/2 mask respirator while conducting spray painting tasks in a spray booth. The employer did not implement a written respiration program to include fit tests. b). On or about, 4/16/19, on site, for the employee required to don a 3M 8210 N95 while conducting wood cutting tasks. The employer did not implement a written respiration program to include fit tests.
Citation ID 02002
Citaton Type Other
Standard Cited 19100242 B
Issuance Date 2019-10-08
Abatement Due Date 2019-11-12
Current Penalty 483.6
Initial Penalty 744.0
Final Order 2019-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a). On or about 4/16/19, on site, for employees using an air hose to clean wood debris. The employer set the p.s.i to 70.

Date of last update: 31 Mar 2025

Sources: New York Secretary of State