Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-15
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2014-08-27
|
Related Activity
Type |
Inspection |
Activity Nr |
955172 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
955198 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 H01 |
Issuance Date |
2014-02-04 |
Current Penalty |
1000.0 |
Initial Penalty |
1700.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: (a) On or about 01/15/14, at the Cambridge Court Townhouse Development, located at Railway Crossing, in Webster, New York, a Dewalt table saw (DW745) was in use without a guard to protect the operator from accidental contact with the moving blade NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2014-02-04 |
Current Penalty |
700.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Relocatable power taps are not intended for use at construction sites. (a) On or about 01/15/14, at the Cambridge Court Townhouse Development, located at Railroad Crossing, in Webster, New York, a power strip was in use to feed a Dewalt DW745 table saw and a Dewalt DW708 compound mitre saw. NO ABATEMENT CERTIFICATION REQUIRED |
|
|