Name: | WIZ HOME IMPROVEMENTS LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 20 Oct 1998 (26 years ago) |
Entity Number: | 2307976 |
ZIP code: | 11209 |
County: | Kings |
Place of Formation: | New York |
Address: | 124 77TH STREET, BROOKLYN, NY, United States, 11209 |
Name | Role | Address |
---|---|---|
WARNER ZLOKLIKOVITS | DOS Process Agent | 124 77TH STREET, BROOKLYN, NY, United States, 11209 |
Start date | End date | Type | Value |
---|---|---|---|
1998-10-20 | 2008-11-05 | Address | 124 77TH STREET, BROOKLYN, NY, 11209, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
081105002054 | 2008-11-05 | BIENNIAL STATEMENT | 2008-10-01 |
061116002112 | 2006-11-16 | BIENNIAL STATEMENT | 2006-10-01 |
981020000147 | 1998-10-20 | ARTICLES OF ORGANIZATION | 1998-10-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339530990 | 0215000 | 2013-12-19 | 206 GARFIELD PLACE, BROOKLYN, NY, 11215 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 901559 |
Safety | Yes |
Inspection Type | Referral |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2013-04-15 |
Emphasis | L: GUTREH, P: GUTREH |
Case Closed | 2015-02-02 |
Related Activity
Type | Referral |
Activity Nr | 814377 |
Safety | Yes |
Type | Inspection |
Activity Nr | 901709 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260403 I02 I |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-28 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. a) 2nd floor: An energized electrical panel board was not provided with a cover. Energized circuit breakers and electrical parts were partially exposed and partially covered with cardboard paper. On or about 04/15/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260405 J01 II |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-28 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported. a) 2nd and 3rd floor: Energized electrical receptacles and light switches were not securely supported. They were left hanging by energized wires attached to the devices. On or about 04/15/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260554 A01 |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-26 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.554(a)(1): The safe working load of the overhead hoist, as determined by the manufacturer, was not indicated on the hoist: a) Behind the house, south side: Employees were operating an overhead hoist motor to hoist a single-point suspension scaffold and a section of metal ventilation duct. The safe working load of the overhead hoist, as determined by the manufacturer, was not indicated on the hoist. On or about 04/15/13. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260554 A02 |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.554(a)(2): Supporting structure to which overhead host was attached did not have a safe working load equal to that of the hoist. a) Behind the house, south side: Employees were operating an overhead hoist motor to hoist a single-point suspension scaffold and a section of metal ventilation duct. The overhead host was attached to a roof brick chimney, which was the supporting structure for the hoist. The chimney did not have a safe working load equal to that of the hoist, and was overloaded and collapsed into brick pieces in an accident. On or about 04/15/13. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 A09 |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-28 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(a)(9): The side rails of ladders were spliced and the strength of the resulting side rail was not at least equivalent to a one-piece side rail made of the same material. a) 3rd floor: Employees used a portable extension ladder for access to the roof to anchor a suspension scaffold and a hoist system. The ladder was made of aluminum and was spliced with extension of both side rails and an additional rung made of wood. The strength of the resulting side rails was not at least equivalent to a one-piece side rail made of the same material. On or about 04/15/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-08-16 |
Abatement Due Date | 2013-08-28 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-09-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed; the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) 3rd floor: Employees used a portable extension ladder for access to the roof to anchor a suspension scaffold and a hoist system. The ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed. The ladder also was not secured at its top. On or about 04/15/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |