Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-04-30
|
Emphasis |
L: FALL
|
Case Closed |
2015-11-04
|
Related Activity
Type |
Complaint |
Activity Nr |
815807 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 B03 |
Issuance Date |
2013-06-04 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1840.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-09-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(b)(3): Every window wall opening at a stairway landing, floor, platform, or balcony, from which there is a drop of more than 4 feet, and where the bottom of the opening is less than 3 feet above the platform or landing, shall be guarded by standard slats, standard grill work (as specified in paragraph (e)(11) of this section), or standard railing. Where the window opening is below the landing, or platform, a standard toe board shall be provided. Site: 529 Waverly Avenue Brooklyn, NY On or about 4/30/13 a) Employees were exposed to fall hazards while standing on the brewing tanks platforms from approximately 20 feet high. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2013-06-04 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1840.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-09-10 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. Site: 529 Waverly Avenue Brooklyn, New York On or about 4/30/13 a) The emergency exit door was kept lock preventing the employees to open it from the inside. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100037 B04 |
Issuance Date |
2013-06-04 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
790.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-09-10 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(4): If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. Site: 529 Waverly Avenue Brooklyn, New York On or about 4/30/13 a) Exit signs indicating the direction of travel were not provided. The direction of travel was not identified. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2013-06-04 |
Abatement Due Date |
2013-06-14 |
Current Penalty |
1050.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. Site: 529 Waverly Avenue Brooklyn, New York On or about 4/30/13 a) Employer did not certify that each forklift truck operator has been trained and evaluated to operate the forkilifts. |
|
|