Search icon

M.C.J. IRON WORKS CORP.

Company Details

Name: M.C.J. IRON WORKS CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 01 Mar 1999 (26 years ago)
Entity Number: 2350976
ZIP code: 11223
County: Kings
Place of Formation: New York
Address: 26 COBECK COURT, BROOKLYN, NY, United States, 11223

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 26 COBECK COURT, BROOKLYN, NY, United States, 11223

Chief Executive Officer

Name Role Address
CARLO LOPOPOLO Chief Executive Officer 26 COBECK COURT, BROOKLYN, NY, United States, 11223

History

Start date End date Type Value
2007-04-04 2008-12-30 Address 2495 MCDONALD AVE, BROOKLYN, NY, 11223, USA (Type of address: Chief Executive Officer)
2007-04-04 2008-12-30 Address 2495 MCDONALD AVE, BROOKLYN, NY, 11223, USA (Type of address: Principal Executive Office)
2007-04-04 2008-12-30 Address 2495 MCDONALD AVENUE, BROOKLYN, NY, 11233, USA (Type of address: Service of Process)
1999-03-01 2007-04-04 Address 2495 MCDONALD AVENUE, BROOKLYN, NY, 11233, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
191230060380 2019-12-30 BIENNIAL STATEMENT 2019-03-01
130415002350 2013-04-15 BIENNIAL STATEMENT 2013-03-01
110518002791 2011-05-18 BIENNIAL STATEMENT 2011-03-01
090316002017 2009-03-16 BIENNIAL STATEMENT 2009-03-01
081230002423 2008-12-30 AMENDMENT TO BIENNIAL STATEMENT 2007-03-01
081230000592 2008-12-30 CERTIFICATE OF CHANGE 2008-12-30
070404002779 2007-04-04 BIENNIAL STATEMENT 2007-03-01
010530000131 2001-05-30 CERTIFICATE OF AMENDMENT 2001-05-30
990301000541 1999-03-01 CERTIFICATE OF INCORPORATION 1999-03-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340620525 0215000 2015-04-29 300 AVE Y, BROOKLYN N.Y. 11223, BROOKLYN, NY, 11223
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2015-04-29
Emphasis L: FALL
Case Closed 2017-06-28

Related Activity

Type Referral
Activity Nr 980211
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2015-10-26
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2015-11-19
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever necessary by reason of hazards of processes or environment: a) Employees were not provided with hardhats or fall protection harnesses when using an aerial lift and when climbing on overhead steel beams to tighten bolts. Employer was erecting a steel storage building. Location: 300 Ave Y, Brooklyn N.Y. On or about 4/29/2015 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-10-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-11-19
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electric shock, were not protected by protective hardhats: a) Employees were not provided with hardhats and were exposed to head injury when erecting a steel storage building. Location: 300 Ave Y, Brooklyn N.Y. On or about 4/29/2015 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2015-10-26
Current Penalty 1900.0
Initial Penalty 2800.0
Final Order 2015-11-19
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt (or harness) was not worn with a lanyard attached to the boom or basket when an employee was working from an aerial lift: a) Employees were exposed to 25 ft fall hazard working in an aerial lift without a fall protection harnesses. Employer was erecting a steel storage building. Location: 300 Ave Y, Brooklyn N.Y. On or about 4/29/2015 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2015-10-26
Current Penalty 1900.0
Initial Penalty 2800.0
Final Order 2015-11-19
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Employee(s) engaged in steel erection activity who were on a walking/working surface with an unprotected side or edge more than 15 feet (4.6m) above a lower level were not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems: a) Employee was not provided with fall protection harnesses and were exposed to 25 ft fall hazard when climbing on overhead steel beams to tighten bolts. Employer was erecting a steel storage building. Location: 300 Ave Y, Brooklyn N.Y. On or about 4/29/2015 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2015-10-26
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2015-11-19
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): The employer did not ensure that employees who are exposed to fall hazards during steel erecting activities were effectively trained in fall protection procedures and hazard recognition, and ensure employee participation in the program: a) Employees were not provided with fall protection training required by OSHA Subpart R Steel Erection standard. Employees were not wearing fall protection harnesses and were exposed to 25 ft fall hazard when climbing on overhead steel beams to tighten bolts. Employer was erecting a steel storage building. Location: 300 Ave Y, Brooklyn N.Y. On or about 4/29/2015 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.

Date of last update: 31 Mar 2025

Sources: New York Secretary of State