344198759
|
0215600
|
2019-07-30
|
68-04 TIDES RD., ARVERNE, NY, 11692
|
|
Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-30
|
Case Closed |
2022-07-22
|
Related Activity
Type |
Accident |
Activity Nr |
1482211 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260754 A |
Issuance Date |
2020-01-16 |
Current Penalty |
11000.0 |
Initial Penalty |
13359.0 |
Final Order |
2020-01-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.754(a): Structural stability was not maintained at all times during the erection process. a) On the fourth floor - Panel D117 was struck by another panel being maneuvered into place, lost stability and fell; on or about 07/30/19. |
|
|
341897270
|
0216000
|
2016-11-03
|
1133 WARBURTON AVE., YONKERS, NY, 10710
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-01-09
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-07-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1189713 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
1154154 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1189815 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1189825 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 IV |
Issuance Date |
2017-03-02 |
Current Penalty |
6360.0 |
Initial Penalty |
9760.0 |
Final Order |
2017-03-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(iv): Employees shall always stand firmly on the floor of the basket, and shall not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position. location: IFO center amenity on or about: 12/22/16 a) An employee was working from a Geanie S-85 aerial lift. The employee was standing on the toeboard of the basket. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2017-03-02 |
Current Penalty |
0.0 |
Initial Penalty |
9760.0 |
Final Order |
2017-03-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn nor a lanyard attached to the boom or basket when working from an aerial lift: location: IFO center amenity on or about: 12/22/16 a) An employee was working from a Geanie S-85 aerial lift. The employee did not have a lanyard attached to the boom or basket. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2017-03-02 |
Current Penalty |
6360.0 |
Initial Penalty |
9760.0 |
Final Order |
2017-03-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: location: south tower, 6th floor on or about: 12/22/16 a) Employees were leaning out of a wall opening while installing temporary support for a concrete pour. The employees, who were exposed to a fall of approximately 50 feet, were not provided with adequate fall protection. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-03-02 |
Current Penalty |
4550.0 |
Initial Penalty |
6972.0 |
Final Order |
2017-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: location: center amenity on or about: 11/3/16 a) Employees were gaining access to and from the balcony using a ladder that extended less than 2 feet above the upper landing surface. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-03-02 |
Abatement Due Date |
2017-03-10 |
Current Penalty |
12730.0 |
Initial Penalty |
19520.0 |
Final Order |
2017-03-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. location: center amenity on or about: 11/3/16 a) Employees were engaged in carpentry work, 11'2" feet above the lower level. The employees were not provided with fall protection. location: center amenity on or about: 12/22/16 b) Employees were installing metal studs, 23 1/2 feet above the lower level. The employees were not provided with fall protection. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. The Extreme Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(1), which was contained in OSHA inspection number 1076326, citation number 1, item number 1 and was affirmed as a final order on 8/31/2015, with respect to a workplace located at 23 Westerly Rd. Ossining, NY. |
|
|
341657245
|
0216000
|
2016-03-22
|
421 SAWMILL RIVER ROAD, HASTINGS ON HUDSON, NY, 10706
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-13
|
Case Closed |
2016-12-06
|
Related Activity
Type |
Referral |
Activity Nr |
1118973 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260757 E04 |
Issuance Date |
2016-08-01 |
Current Penalty |
2000.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.757(e)(4): No bundle of decking may be placed on steel joists until all bridging has been installed and anchored and all joist bearing ends attached: a) Building C- A roof steel joist collapsed on an employee during the loading of a bundle of corrugated roof decking. The joists were not properly secured during installation; on or about 3/17/16. |
|
|
341502250
|
0216000
|
2016-02-25
|
421 SAWMILL RIVER ROAD, HASTINGS ON HUDSON, NY, 10706
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-13
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-12-13
|
Related Activity
Type |
Referral |
Activity Nr |
1147628 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260602 C01 II |
Issuance Date |
2016-07-27 |
Abatement Due Date |
2016-08-15 |
Current Penalty |
2000.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval: a) On jobsite: Employee fell approximately 20 ft while elevated in a wooden man made basket attached to a forklift; on or about 2/25/16. |
|
|
340763267
|
0216000
|
2015-06-25
|
23 WESTERLY RD., OSSINING, NY, 10562
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-25
|
Emphasis |
L: LOCALTARG, L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2016-02-22
|
Related Activity
Type |
Inspection |
Activity Nr |
1077322 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2015-07-24 |
Abatement Due Date |
2015-08-05 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-08-31 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. 23 Westerly Rd., Ossining NY a) Employees working approximately sixty feet high were not protected from falling while connecting and handling external wall panels at an unprotected open edge; on or about 06-25-2015. b) Employees working approximately sixty feet high were not protected from falling while handling and receiving external wall panels being hoisted by a crane; on or about 06-25-2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261425 A |
Issuance Date |
2015-07-24 |
Abatement Due Date |
2015-08-05 |
Current Penalty |
1680.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-08-31 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1425(a): 29 CFR 1926.1425(a): Where available, hoisting routes that minimize the exposure of employees to hoisted loads were not used, to the extent consistent with public safety. 23 Westerly Rd., Ossining NY a) Employer failed to ensure that the employees waiting for the wall panels being hoisted stay away of the load's hoist route; on or about 06-25-2015. |
|
|