Search icon

C.M.D. WOODWORKING CORP.

Company Details

Name: C.M.D. WOODWORKING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 10 May 1999 (26 years ago)
Entity Number: 2376518
ZIP code: 11766
County: Suffolk
Place of Formation: New York
Address: 4 WENDY CT, MT SINAI, NY, United States, 11766

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
SEVERO FERNANDES Chief Executive Officer 4 WENDY CT, MT SINAI, NY, United States, 11766

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 4 WENDY CT, MT SINAI, NY, United States, 11766

History

Start date End date Type Value
2001-05-30 2005-08-16 Address 354 SHELTER RD, RONKONKOMA, NY, 11779, USA (Type of address: Chief Executive Officer)
2001-05-30 2005-08-16 Address 354 SHELTER RD, RONKONKOMA, NY, 11779, USA (Type of address: Principal Executive Office)
2001-05-30 2005-08-16 Address 354 SHELTER RD, RONKONKOMA, NY, 11779, USA (Type of address: Service of Process)
1999-05-10 2022-02-17 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1999-05-10 2001-05-30 Address 125 GATELOT AVE., RONKONKOMA, NY, 11779, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
110624002329 2011-06-24 BIENNIAL STATEMENT 2011-05-01
070521002561 2007-05-21 BIENNIAL STATEMENT 2007-05-01
050816002881 2005-08-16 BIENNIAL STATEMENT 2005-05-01
010530002400 2001-05-30 BIENNIAL STATEMENT 2001-05-01
990510000594 1999-05-10 CERTIFICATE OF INCORPORATION 1999-05-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340019769 0214700 2014-10-20 57 HOWARD ST., HICKSVILLE, NY, 11801
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-20
Emphasis L: FALL, P: FALL
Case Closed 2015-06-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-10-30
Abatement Due Date 2014-11-07
Current Penalty 900.0
Initial Penalty 1200.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite: Employees working directly under employees using tools and materials such as nail guns, siding material, and window installations were not using head protection; on or about 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-10-30
Abatement Due Date 2014-11-07
Current Penalty 900.0
Initial Penalty 1200.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite: Employees were installing capping and windows with nail guns and were not provided with eye protection; on or about 10/20/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-10-30
Abatement Due Date 2014-11-05
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees installing windows to the second story from the first story overhang approximately 11 feet above the ground did not have fall protection; on or about 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-10-30
Abatement Due Date 2014-12-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite: Employees were installing windows to the second story of a residential building from the first story overhang approximately 11 feet above the ground and had not been trained in fall protection; on or about 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-10-30
Abatement Due Date 2014-11-07
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite: Employees were accessing a first story overhang approximately 11 feet above the ground. The portable ladder used to access the overhang extended approximately 8 inches above the landing surface; on, or about, 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-10-30
Abatement Due Date 2014-11-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite: Employees were using a folding stepladder in the folded position to install capping to the exterior of the existing residential building; on or about 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2014-10-30
Abatement Due Date 2014-12-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-18
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) Worksite: Employees were accessing a first story overhang approximately 11 feet above the ground. The portable ladder used to access the overhang extended approximately 8 inches above the landing surface and was not plumb. The employees had not been trained in ladder use and safety; on, or about, 10/20/2014. b) Worksite: An employee was using a folding stepladder in the folded position to install capping to the exterior of the existing residential building. The employee had not been trained in ladder use and safety; on, or about, 10/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.