Search icon

A & M BUILDERS LLC

Company Details

Name: A & M BUILDERS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 19 May 1999 (26 years ago)
Entity Number: 2380103
ZIP code: 11223
County: Kings
Place of Formation: New York
Address: 2390 MCDONALD AVE, BROOKLYN, NY, United States, 11223

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 2390 MCDONALD AVE, BROOKLYN, NY, United States, 11223

History

Start date End date Type Value
1999-05-19 2001-05-01 Address 2390 MCDONALD AVENUE, BROOKLYN, NY, 11223, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
030505002354 2003-05-05 BIENNIAL STATEMENT 2003-05-01
010501002088 2001-05-01 BIENNIAL STATEMENT 2001-05-01
990519000608 1999-05-19 ARTICLES OF ORGANIZATION 1999-05-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343838975 0213600 2019-03-07 600 RIVER ROAD, NORTH TONAWANDA, NY, 14120
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-03-07
Emphasis L: FALL, P: FALL
Case Closed 2019-08-20

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2019-05-15
Current Penalty 1449.0
Initial Penalty 1449.0
Final Order 2019-08-19
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) On or about 3/7/19, at the two-story building area of the site, North Tonawanda, NY. Employee, worked from a scaffold platform made of 2X8 lumber; with one end sitting on the rung of a step ladder and the other end sitting on a bracket made of 2X4 lumber, was exposed to fall of 7 feet. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2019-05-15
Current Penalty 1449.0
Initial Penalty 1449.0
Final Order 2019-08-19
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end: a) On or about 3/7/18, at the two-story building area of the site, North Tonawanda, NY. Employee, worked from a scaffold platform made of 2X8 lumber; with one end sitting on the rung of a step ladder and the other end sitting on a bracket made of 2X4 lumber, lacked guardrails on the bracket side, where the platform extended 18 inches over its support, to block employee from accessing the cantilever end. Employee was exposed to fall hazard. NO ABATEMENT CERTIFICATION REQUIRED