Search icon

EVERGREEN ELECTRICAL CORP.

Company Details

Name: EVERGREEN ELECTRICAL CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 21 May 1999 (26 years ago)
Entity Number: 2380988
ZIP code: 11232
County: Kings
Place of Formation: New York
Address: 4223 1ST AVENUE, FL 3, BROOKLYN, NY, United States, 11232

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
EVERGREEN ELECTRICAL CORP. DOS Process Agent 4223 1ST AVENUE, FL 3, BROOKLYN, NY, United States, 11232

Chief Executive Officer

Name Role Address
YEVGENY KOLTUNOV Chief Executive Officer 4223 1ST AVENUE, FL 3, BROOKLYN, NY, United States, 11232

History

Start date End date Type Value
2001-05-04 2013-05-07 Address 133 50TH ST, BROOKLYN, NY, 11232, USA (Type of address: Chief Executive Officer)
2001-05-04 2013-05-07 Address 133 50TH ST, BROOKLYN, NY, 11232, USA (Type of address: Principal Executive Office)
1999-05-21 2013-05-07 Address 133 50TH STREET, BROOKLYN, NY, 11232, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
130507006362 2013-05-07 BIENNIAL STATEMENT 2013-05-01
110518002717 2011-05-18 BIENNIAL STATEMENT 2011-05-01
090421002604 2009-04-21 BIENNIAL STATEMENT 2009-05-01
050622002587 2005-06-22 BIENNIAL STATEMENT 2005-05-01
030424002640 2003-04-24 BIENNIAL STATEMENT 2003-05-01
010504002415 2001-05-04 BIENNIAL STATEMENT 2001-05-01
990521000458 1999-05-21 CERTIFICATE OF INCORPORATION 1999-05-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334556164 0216000 2012-06-01 25 STATE ST, OSSINING, NY, 10562
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2012-10-19
Case Closed 2013-10-30

Related Activity

Type Inspection
Activity Nr 453393
Safety Yes
Type Inspection
Activity Nr 455534
Safety Yes
Type Inspection
Activity Nr 455673
Safety Yes
Type Referral
Activity Nr 377687
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 A02 II B
Issuance Date 2012-10-23
Abatement Due Date 2012-10-24
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2012-12-19
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(B): Runs of open conductors used as temporary wiring branch circuits were located where the conductors would be subject to physical damage, or the conductors were fastened at intervals exceeding 10 feet: Location: 25 State St Ossining NY 10562 On or about 6/1/12, a) Branch circuits running from a panel outside to inside the building were not protected from physical damage and were not fastened at least every 10 feet. They were in direct contact with metal scaffolding and a metal extension ladder used to access the scaffolding.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 B01
Issuance Date 2012-10-23
Abatement Due Date 2012-10-24
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-12-19
Nr Instances 3
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, and fittings were not protected from abrasion, unused openings in cabinets, boxes, and fittings were not effectively closed and openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed: Location: 25 State St Ossining NY 10562 On or about 6/1/12, a) A conductor entering a circuit breaker panel was not protected from abrasion. b) An opening in a circuit breaker panel through which a conductor entered was not effectively closed. c) There were several unused openings in a circuit breaker panel that were not effectively closed.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 E01
Issuance Date 2012-10-23
Abatement Due Date 2012-10-24
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-12-19
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(e)(1): In wet locations, cabinets, cutout boxes, fittings, boxes and panelboard enclosures were not weatherproof: Location: 25 State St Ossining NY 10562 On or about 6/1/12, a) A circuit breaker panel designed for indoor use was installed outside exposed to the elements.
308661511 0215000 2005-05-17 125 COURT STREET, BROOKLYN, NY, 11201
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2005-05-17
Emphasis L: FALL
Case Closed 2007-05-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260452 W02
Issuance Date 2005-06-02
Abatement Due Date 2005-06-07
Current Penalty 2000.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
308026251 0215000 2004-08-31 211 ATLANTIC AVENUE, BROOKLYN, NY, 11201
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2004-09-01
Emphasis L: FALL
Case Closed 2004-10-08

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2004-09-16
Abatement Due Date 2004-09-21
Current Penalty 1000.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B20
Issuance Date 2004-09-16
Abatement Due Date 2004-09-21
Nr Instances 1
Nr Exposed 1
Gravity 02

Date of last update: 31 Mar 2025

Sources: New York Secretary of State