Name: | B.W. ELLIOTT MANUFACTURING CO., LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 20 Jul 1999 (26 years ago) |
Entity Number: | 2400157 |
ZIP code: | 12207 |
County: | Broome |
Place of Formation: | New York |
Address: | 80 STATE STREET, ALBANY, NY, United States, 12207 |
Unique Entity ID | Expiration Date | Physical Address | Mailing Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
L5YANW2XSND4 | 2025-04-03 | 11 BECKWITH AVE, BINGHAMTON, NY, 13901, 1726, USA | P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
URL | www.elliottmfg.com |
Congressional District | 19 |
State/Country of Incorporation | NY, USA |
Activation Date | 2024-04-05 |
Initial Registration Date | 2001-07-02 |
Entity Start Date | 1932-01-01 |
Fiscal Year End Close Date | Aug 31 |
Service Classifications
NAICS Codes | 326291, 331222, 332618, 332721, 333112, 333613, 335932, 336413 |
Points of Contacts
Electronic Business | |
---|---|
Title | PRIMARY POC |
Name | HARRIET BEAMS |
Role | FINANCE |
Address | B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA |
Title | ALTERNATE POC |
Name | HARRIET BEAMS |
Address | B W ELLIOTT MFG CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA |
Government Business | |
---|---|
Title | PRIMARY POC |
Name | CAROLYN DOYLE |
Role | CUSTOMER SERVICE MANAGER |
Address | 11BECKWITH AVE, BINGHAMTON, NY, 13901, 0773, USA |
Title | ALTERNATE POC |
Name | JENNI SOTO |
Role | CUSTOMER SERVICE MANAGER |
Address | B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, USA |
Past Performance | |
---|---|
Title | PRIMARY POC |
Name | AIMEE FENICK |
Role | CUSTOMER SERVICE MANAGER |
Address | 11 BECKWITH AVE., 11, BINGHAMTON, NY, 13902, 0773, USA |
Title | ALTERNATE POC |
Name | DAN VERDON |
Address | B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA |
CAGE number | Status | Type | Established | CAGE Update Date | CAGE Expiration | SAM Expiration | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72166 | Active | U.S./Canada Manufacturer | 1974-11-04 | 2024-04-05 | 2029-04-05 | 2025-04-03 | |||||||||||||
|
POC | CAROLYN DOYLE |
Phone | +1 607-772-0404 |
Address | 11 BECKWITH AVE, BINGHAMTON, NY, 13901 1726, UNITED STATES |
Ownership of Offeror Information
Highest Level Owner | Information not Available |
---|
Immediate Level Owner | Information not Available |
---|
List of Offerors (0) | Information not Available |
---|
LEI number | Registered As | Jurisdiction Of Formation | General Category | Entity Status | Entity created at | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2549002RB0HOOCKVVH93 | 2400157 | US-NY | GENERAL | ACTIVE | 1999-07-20 | |||||||||||||||||||
|
Legal | C/O CORPORATION SERVICE COMPANY, 80 STATE STREET, ALBANY, US-NY, US, 12207 |
Headquarters | N19 W24200 Riverwood Drive, Suite 300., Waukesha, US-WI, US, 53188 |
Registration details
Registration Date | 2020-08-05 |
Last Update | 2024-08-11 |
Status | LAPSED |
Next Renewal | 2024-08-10 |
LEI Issuer | 5493001KJTIIGC8Y1R12 |
Corroboration Level | FULLY_CORROBORATED |
Data Validated As | 2400157 |
Name | Role | Address |
---|---|---|
CORPORATION SERVICE COMPANY | Agent | 80 STATE STREET, ALBANY, NY, 12207 |
Name | Role | Address |
---|---|---|
CORPORATION SERVICE COMPANY | DOS Process Agent | 80 STATE STREET, ALBANY, NY, United States, 12207 |
Start date | End date | Type | Value |
---|---|---|---|
2017-02-24 | 2023-07-17 | Address | 80 STATE STREET, ALBANY, NY, 12207, 2543, USA (Type of address: Registered Agent) |
2017-02-24 | 2023-07-17 | Address | 80 STATE STREET, ALBANY, NY, 12207, 2543, USA (Type of address: Service of Process) |
2012-10-30 | 2017-02-24 | Address | 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Registered Agent) |
2012-08-24 | 2017-02-24 | Address | 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process) |
2008-11-18 | 2012-10-30 | Address | 875 AVENUE OF AMERICAS STE 501, NEW YORK, NY, 10001, USA (Type of address: Registered Agent) |
2008-11-18 | 2012-08-24 | Address | 875 AVENUE OF AMERICAS STE 501, NEW YORK, NY, 10001, USA (Type of address: Service of Process) |
2005-01-21 | 2008-11-18 | Address | 11 BECKWITH AVE, BINGHAMTON, NY, 13901, USA (Type of address: Service of Process) |
1999-08-31 | 2005-01-21 | Address | 37 MILFORD STREET, BINGHAMTON, NY, 13904, USA (Type of address: Service of Process) |
1999-07-20 | 1999-08-31 | Address | 37 MILFORD STREET, BINGHAMTON, NY, 13904, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
230717002090 | 2023-07-17 | BIENNIAL STATEMENT | 2023-07-01 |
210701001187 | 2021-07-01 | BIENNIAL STATEMENT | 2021-07-01 |
191118060233 | 2019-11-18 | BIENNIAL STATEMENT | 2019-07-01 |
171212006109 | 2017-12-12 | BIENNIAL STATEMENT | 2017-07-01 |
170224000066 | 2017-02-24 | CERTIFICATE OF CHANGE | 2017-02-24 |
150701007090 | 2015-07-01 | BIENNIAL STATEMENT | 2015-07-01 |
130709006922 | 2013-07-09 | BIENNIAL STATEMENT | 2013-07-01 |
121030000305 | 2012-10-30 | CERTIFICATE OF CHANGE (BY AGENT) | 2012-10-30 |
120824000828 | 2012-08-24 | CERTIFICATE OF CHANGE (BY AGENT) | 2012-08-24 |
110629002173 | 2011-06-29 | BIENNIAL STATEMENT | 2011-07-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343080701 | 0215800 | 2018-04-10 | 11 BECKWITH AVENUE, BINGHAMTON, NY, 13901 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-06-05 |
Current Penalty | 4711.8 |
Initial Penalty | 7853.0 |
Final Order | 2018-06-15 |
Nr Instances | 7 |
Nr Exposed | 14 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) MCAD Area, on or about 3/19/18: Denison Multipress was not provided with guarding to prevent employees from having any part of their body in the danger zone during the operating cycle. b) Machine Shop, on or about 4/10/18: Single spindle drill press used for secondary operations was used without a guard. Employees exposed to contact with the rotating chuck and tool during operation. c) ROG Assembly, on or about 4/10/18: Bridgeport Milling machine was not equipped with guard to prevent contact with the rotating chuck and tool. d) Maintenance, on or about 4/10/18: Ridgid pipe threader activated by a manually operated on/off switch that would not automatically shut the machine off should the operator be inadvertently caught up in the rotating parts. e) Aerospace, on or about 4/11/18: Pressure Lubrication Rack was not provided with guarding to prevent the operator from nip point hazards when the hose fixture is cycled back to the starting position. f) Machine Shop, on or about 4/10/18: Bench grinder, Model 09012162, was missing the wheel side guard, thereby exposing the operator to the rotating end nut. g) Stress Relief Area, on or about 4/10/18: Stress Relief Machines #1, #3, #4, #5 and #11, had unguarded rollers at various locations which exposed employees to in-running nip point hazards. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-06-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-06-15 |
Nr Instances | 4 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Heavy Assembly, Work Center 15001, on or about 4/10/18: Construction Cut-off Saw was not provided with adequate point of operation guarding in that the guard did not prevent employees from having hands in the danger zone during the operating cycle. The operator hand feeds and hold 7/8-inch diameter material into the point of operation and cycles the machine using a foot pedal. b) MCAD, Work Center 5, on or about 4/3/18: Ring Swager Crimper, ID No. 444, was not provided with adequate point of operation guarding in that the operator could reach through the guard and into the point of operation. c) Hydraulic Hose Cell, on or about 4/11/18: Hydraulic Hose Vulconizer was not provided with adequate point of operation guarding in that it did not prevent the operator from having their hands in the danger zone during the operating cycle. The operator hand feeds and holds 1-inch diameter hose material into the point of operation and cycles the machine with a foot pedal. d) Aerospace, on or about 4/11/18: Cut-off saw used to cut 1/2-inch to 7/8-inch diameter braided casing was not provided with adequate point of operation guarding and did not prevent employees from having any part of their hands in the danger zone during the operating cycle. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A05 |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-05-29 |
Current Penalty | 4711.8 |
Initial Penalty | 7853.0 |
Final Order | 2018-06-15 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) Casing, High Pressure Boiler Room, on or about 4/11/18: Exhaust fan blade guard, 4 feet 7 inches above the floor, had openings measuring 1-3/8 inches. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19100219 C02 I |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-05-31 |
Current Penalty | 3769.2 |
Initial Penalty | 6282.0 |
Final Order | 2018-06-15 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Casing Department, on or about 4/11/18: (2) Two casing payoff's had unguarded shafts that were positioned approximately 2 inches above the floor. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19100219 C04 I |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-06-07 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-06-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Winding Long Shop, on or about 2/12/18: Lathe had an unguarded end shaft that projected more than one half the diameter of the shaft. |
Citation ID | 01004A |
Citaton Type | Serious |
Standard Cited | 19100219 D01 |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-05-31 |
Current Penalty | 3769.2 |
Initial Penalty | 6282.0 |
Final Order | 2018-06-15 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Winding Long Shop, on or about 2/12/18: The Lathe belt and pulley drive was not provided with adequate guarding over the in-running nip points . b) Aerospace, Work Center 2, on or about 4/11/18: The Rotary Swager belt and pulley drive was not provided with adequate guarding over the in-running nip points. |
Citation ID | 01004B |
Citaton Type | Serious |
Standard Cited | 19100219 E01 |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-05-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-06-15 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(e)(1): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to the requirements specified in 29 CFR1910.219 (m) and (o). a) Winding Long Shop, on or about 2/12/18: The Lathe belt drive was not provided with adequate guarding over the in-running nip points . b) Aerospace, Work Center 2, on or about 4/11/18: The Rotary Swager belt drive was not provided with adequate guarding over the in-running nip points. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100147 C06 I |
Issuance Date | 2018-05-11 |
Abatement Due Date | 2018-06-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-06-15 |
Nr Instances | 1 |
Nr Exposed | 8 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) B.W. Elliott Manufacturing Co. LLC, on or about 4/11/18: The employer did not conduct a periodic inspection of their energy control procedures at least annually. Employees perform servicing and/or maintenance activities on machinery and equipment such as but not limited to: CNC Mills, Punch Presses, Winders, Air Crimpers and Core Machines. |
Date of last update: 31 Mar 2025
Sources: New York Secretary of State