Search icon

B.W. ELLIOTT MANUFACTURING CO., LLC

Company Details

Name: B.W. ELLIOTT MANUFACTURING CO., LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 20 Jul 1999 (26 years ago)
Entity Number: 2400157
ZIP code: 12207
County: Broome
Place of Formation: New York
Address: 80 STATE STREET, ALBANY, NY, United States, 12207

Unique Entity ID

Unique Entity ID Expiration Date Physical Address Mailing Address
L5YANW2XSND4 2025-04-03 11 BECKWITH AVE, BINGHAMTON, NY, 13901, 1726, USA P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA

Business Information

URL www.elliottmfg.com
Congressional District 19
State/Country of Incorporation NY, USA
Activation Date 2024-04-05
Initial Registration Date 2001-07-02
Entity Start Date 1932-01-01
Fiscal Year End Close Date Aug 31

Service Classifications

NAICS Codes 326291, 331222, 332618, 332721, 333112, 333613, 335932, 336413

Points of Contacts

Electronic Business
Title PRIMARY POC
Name HARRIET BEAMS
Role FINANCE
Address B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA
Title ALTERNATE POC
Name HARRIET BEAMS
Address B W ELLIOTT MFG CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA
Government Business
Title PRIMARY POC
Name CAROLYN DOYLE
Role CUSTOMER SERVICE MANAGER
Address 11BECKWITH AVE, BINGHAMTON, NY, 13901, 0773, USA
Title ALTERNATE POC
Name JENNI SOTO
Role CUSTOMER SERVICE MANAGER
Address B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, USA
Past Performance
Title PRIMARY POC
Name AIMEE FENICK
Role CUSTOMER SERVICE MANAGER
Address 11 BECKWITH AVE., 11, BINGHAMTON, NY, 13902, 0773, USA
Title ALTERNATE POC
Name DAN VERDON
Address B W ELLIOTT MFG. CO, LLC, P.O. BOX 773, BINGHAMTON, NY, 13902, 0773, USA

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
72166 Active U.S./Canada Manufacturer 1974-11-04 2024-04-05 2029-04-05 2025-04-03

Contact Information

POC CAROLYN DOYLE
Phone +1 607-772-0404
Address 11 BECKWITH AVE, BINGHAMTON, NY, 13901 1726, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

Legal Entity Identifier

LEI number Registered As Jurisdiction Of Formation General Category Entity Status Entity created at
2549002RB0HOOCKVVH93 2400157 US-NY GENERAL ACTIVE 1999-07-20

Addresses

Legal C/O CORPORATION SERVICE COMPANY, 80 STATE STREET, ALBANY, US-NY, US, 12207
Headquarters N19 W24200 Riverwood Drive, Suite 300., Waukesha, US-WI, US, 53188

Registration details

Registration Date 2020-08-05
Last Update 2024-08-11
Status LAPSED
Next Renewal 2024-08-10
LEI Issuer 5493001KJTIIGC8Y1R12
Corroboration Level FULLY_CORROBORATED
Data Validated As 2400157

Agent

Name Role Address
CORPORATION SERVICE COMPANY Agent 80 STATE STREET, ALBANY, NY, 12207

DOS Process Agent

Name Role Address
CORPORATION SERVICE COMPANY DOS Process Agent 80 STATE STREET, ALBANY, NY, United States, 12207

History

Start date End date Type Value
2017-02-24 2023-07-17 Address 80 STATE STREET, ALBANY, NY, 12207, 2543, USA (Type of address: Registered Agent)
2017-02-24 2023-07-17 Address 80 STATE STREET, ALBANY, NY, 12207, 2543, USA (Type of address: Service of Process)
2012-10-30 2017-02-24 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Registered Agent)
2012-08-24 2017-02-24 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)
2008-11-18 2012-10-30 Address 875 AVENUE OF AMERICAS STE 501, NEW YORK, NY, 10001, USA (Type of address: Registered Agent)
2008-11-18 2012-08-24 Address 875 AVENUE OF AMERICAS STE 501, NEW YORK, NY, 10001, USA (Type of address: Service of Process)
2005-01-21 2008-11-18 Address 11 BECKWITH AVE, BINGHAMTON, NY, 13901, USA (Type of address: Service of Process)
1999-08-31 2005-01-21 Address 37 MILFORD STREET, BINGHAMTON, NY, 13904, USA (Type of address: Service of Process)
1999-07-20 1999-08-31 Address 37 MILFORD STREET, BINGHAMTON, NY, 13904, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230717002090 2023-07-17 BIENNIAL STATEMENT 2023-07-01
210701001187 2021-07-01 BIENNIAL STATEMENT 2021-07-01
191118060233 2019-11-18 BIENNIAL STATEMENT 2019-07-01
171212006109 2017-12-12 BIENNIAL STATEMENT 2017-07-01
170224000066 2017-02-24 CERTIFICATE OF CHANGE 2017-02-24
150701007090 2015-07-01 BIENNIAL STATEMENT 2015-07-01
130709006922 2013-07-09 BIENNIAL STATEMENT 2013-07-01
121030000305 2012-10-30 CERTIFICATE OF CHANGE (BY AGENT) 2012-10-30
120824000828 2012-08-24 CERTIFICATE OF CHANGE (BY AGENT) 2012-08-24
110629002173 2011-06-29 BIENNIAL STATEMENT 2011-07-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343080701 0215800 2018-04-10 11 BECKWITH AVENUE, BINGHAMTON, NY, 13901
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-04-11
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2018-06-20

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2018-05-11
Abatement Due Date 2018-06-05
Current Penalty 4711.8
Initial Penalty 7853.0
Final Order 2018-06-15
Nr Instances 7
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) MCAD Area, on or about 3/19/18: Denison Multipress was not provided with guarding to prevent employees from having any part of their body in the danger zone during the operating cycle. b) Machine Shop, on or about 4/10/18: Single spindle drill press used for secondary operations was used without a guard. Employees exposed to contact with the rotating chuck and tool during operation. c) ROG Assembly, on or about 4/10/18: Bridgeport Milling machine was not equipped with guard to prevent contact with the rotating chuck and tool. d) Maintenance, on or about 4/10/18: Ridgid pipe threader activated by a manually operated on/off switch that would not automatically shut the machine off should the operator be inadvertently caught up in the rotating parts. e) Aerospace, on or about 4/11/18: Pressure Lubrication Rack was not provided with guarding to prevent the operator from nip point hazards when the hose fixture is cycled back to the starting position. f) Machine Shop, on or about 4/10/18: Bench grinder, Model 09012162, was missing the wheel side guard, thereby exposing the operator to the rotating end nut. g) Stress Relief Area, on or about 4/10/18: Stress Relief Machines #1, #3, #4, #5 and #11, had unguarded rollers at various locations which exposed employees to in-running nip point hazards.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2018-05-11
Abatement Due Date 2018-06-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-15
Nr Instances 4
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Heavy Assembly, Work Center 15001, on or about 4/10/18: Construction Cut-off Saw was not provided with adequate point of operation guarding in that the guard did not prevent employees from having hands in the danger zone during the operating cycle. The operator hand feeds and hold 7/8-inch diameter material into the point of operation and cycles the machine using a foot pedal. b) MCAD, Work Center 5, on or about 4/3/18: Ring Swager Crimper, ID No. 444, was not provided with adequate point of operation guarding in that the operator could reach through the guard and into the point of operation. c) Hydraulic Hose Cell, on or about 4/11/18: Hydraulic Hose Vulconizer was not provided with adequate point of operation guarding in that it did not prevent the operator from having their hands in the danger zone during the operating cycle. The operator hand feeds and holds 1-inch diameter hose material into the point of operation and cycles the machine with a foot pedal. d) Aerospace, on or about 4/11/18: Cut-off saw used to cut 1/2-inch to 7/8-inch diameter braided casing was not provided with adequate point of operation guarding and did not prevent employees from having any part of their hands in the danger zone during the operating cycle.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A05
Issuance Date 2018-05-11
Abatement Due Date 2018-05-29
Current Penalty 4711.8
Initial Penalty 7853.0
Final Order 2018-06-15
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) Casing, High Pressure Boiler Room, on or about 4/11/18: Exhaust fan blade guard, 4 feet 7 inches above the floor, had openings measuring 1-3/8 inches.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100219 C02 I
Issuance Date 2018-05-11
Abatement Due Date 2018-05-31
Current Penalty 3769.2
Initial Penalty 6282.0
Final Order 2018-06-15
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Casing Department, on or about 4/11/18: (2) Two casing payoff's had unguarded shafts that were positioned approximately 2 inches above the floor.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2018-05-11
Abatement Due Date 2018-06-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Winding Long Shop, on or about 2/12/18: Lathe had an unguarded end shaft that projected more than one half the diameter of the shaft.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2018-05-11
Abatement Due Date 2018-05-31
Current Penalty 3769.2
Initial Penalty 6282.0
Final Order 2018-06-15
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Winding Long Shop, on or about 2/12/18: The Lathe belt and pulley drive was not provided with adequate guarding over the in-running nip points . b) Aerospace, Work Center 2, on or about 4/11/18: The Rotary Swager belt and pulley drive was not provided with adequate guarding over the in-running nip points.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100219 E01
Issuance Date 2018-05-11
Abatement Due Date 2018-05-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-15
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(1): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to the requirements specified in 29 CFR1910.219 (m) and (o). a) Winding Long Shop, on or about 2/12/18: The Lathe belt drive was not provided with adequate guarding over the in-running nip points . b) Aerospace, Work Center 2, on or about 4/11/18: The Rotary Swager belt drive was not provided with adequate guarding over the in-running nip points.
Citation ID 02001
Citaton Type Other
Standard Cited 19100147 C06 I
Issuance Date 2018-05-11
Abatement Due Date 2018-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-15
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) B.W. Elliott Manufacturing Co. LLC, on or about 4/11/18: The employer did not conduct a periodic inspection of their energy control procedures at least annually. Employees perform servicing and/or maintenance activities on machinery and equipment such as but not limited to: CNC Mills, Punch Presses, Winders, Air Crimpers and Core Machines.

Date of last update: 31 Mar 2025