Search icon

TPI ARCADE, INC.

Company Details

Name: TPI ARCADE, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 23 Jul 1999 (26 years ago)
Date of dissolution: 01 Jan 2023
Entity Number: 2401514
ZIP code: 14009
County: Wyoming
Place of Formation: New York
Address: 7888 ROUTE 98, ARCADE, NY, United States, 14009
Principal Address: 7888 RT 98, ARCADE, NY, United States, 14009

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 7888 ROUTE 98, ARCADE, NY, United States, 14009

Chief Executive Officer

Name Role Address
GERALD BYRNE Chief Executive Officer 7888 RT 98, ARCADE, NY, United States, 14009

History

Start date End date Type Value
2003-07-10 2015-07-17 Address 7888 RT 98, ARCADE, NY, 14009, USA (Type of address: Chief Executive Officer)
2001-07-10 2003-07-10 Address 3925 CALIFORNIA RD, ORCHARD PARK, NY, 14127, USA (Type of address: Chief Executive Officer)
2001-07-10 2003-07-10 Address 3925 CALIFORNIA RD, ORCHARD PARK, NY, 14127, USA (Type of address: Principal Executive Office)
1999-07-23 2022-05-11 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1999-07-23 2002-08-13 Address 3925 CALIFORNIA ROAD, ORCHARD PARK, NY, 14127, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
221230002152 2022-12-30 CERTIFICATE OF MERGER 2023-01-01
220511001379 2022-05-11 BIENNIAL STATEMENT 2021-07-01
191007060687 2019-10-07 BIENNIAL STATEMENT 2019-07-01
170705007276 2017-07-05 BIENNIAL STATEMENT 2017-07-01
150717006112 2015-07-17 BIENNIAL STATEMENT 2015-07-01
130731002232 2013-07-31 BIENNIAL STATEMENT 2013-07-01
110810002611 2011-08-10 BIENNIAL STATEMENT 2011-07-01
090724003093 2009-07-24 BIENNIAL STATEMENT 2009-07-01
070723002352 2007-07-23 BIENNIAL STATEMENT 2007-07-01
050831002083 2005-08-31 BIENNIAL STATEMENT 2005-07-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345982110 0213600 2022-05-25 7888 ROUTE 98, ARCADE, NY, 14009
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-05-25
Emphasis N: AMPUTATE
Case Closed 2023-01-04

Related Activity

Type Referral
Activity Nr 1897734
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2022-09-16
Abatement Due Date 2022-10-11
Current Penalty 7000.0
Initial Penalty 13052.0
Contest Date 2022-10-12
Final Order 2022-11-07
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) On or about 5/22/2022, in the Molding Department, employees were exposed to crush between hazards when working around the mold transfer shuttle. Employee's head got crushed between the mold transfer shuttle and support I beam when the shuttle was moving away from the machine as the employee was walking to the other side of the mold transfer shuttle. b) On or about 5/25/2022, in the Molding Department, employees were exposed to crush between hazards when working around the mold transfer shuttle. Employees are exposed to crush between hazards when the shuttle moves towards the machine, as it creates a pinch point between the I beam and the rear of the mold transfer shuttle. ABATEMENT DOCUMENTATION REQUIRED
343173233 0213600 2018-05-18 7888 ROUTE 98, ARCADE, NY, 14009
Inspection Type Fat/Cat
Scope Partial
Safety/Health Safety
Close Conference 2018-05-18
Emphasis N: DUSTEXPL
Case Closed 2018-11-30

Related Activity

Type Accident
Activity Nr 1340138
Type Referral
Activity Nr 1338813
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100094 A04 I
Issuance Date 2018-10-29
Abatement Due Date 2018-11-14
Current Penalty 10348.0
Initial Penalty 12934.0
Final Order 2018-10-09
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.94(a)(4)(i): The construction, installation, inspection, and maintenance of exhaust systems shall conform to the principles and requirements set forth in American National Standard Fundamentals Governing the Design and Operation of Local Exhaust Systems, Z9.2-1960, and ANSI Z33.1-1961, which are incorporated by reference as specified in �� 1910.6. a) On or about 05/17/18, in the grinding department at TPI Arcade, located at 7888 Route 98 in Arcade, New York, the employer did not maintain, inspect or clean the duct work of the dust collection unit used to ventilate and filter exhaust from a Wheelabrator Blast Machine, to prevent the accumulation of 9,560 lbs. or 4.7 tons of steel shot particles and cause the duct pipe to collapse. Employees were exposed to fatal crushing injuries. b) On or about 05/17/18, in the grinding department at TPI Arcade, located at 7888 Route 98 in Arcade, New York, the employer did not install an appropriately designed local exhaust system that includes clean out ports to facilitate inspection and maintenance as required by ANSI Z9.2-1960. Employees were exposed to fatal crushing injuries. ABATEMENT DOCUMENTATION REQUIRED
339378473 0213600 2013-09-05 7888 RT 98, ARCADE, NY, 14009
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-09-11
Emphasis N: SSTARG12, P: SSTARG12
Case Closed 2013-10-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 A02 III A
Issuance Date 2013-09-26
Abatement Due Date 2013-10-21
Current Penalty 1338.75
Initial Penalty 1785.0
Final Order 2013-10-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(a)(2)(iii)(A): Work on cord and plug connected electric equipment for which exposure to the hazards of unexpected energization or start up of the equipment is controlled by the unplugging of the equipment from the energy source and by the plug being under the exclusive control of the employee performing the servicing or maintenance. a) On or about 9/5/13, employees did not de-energize cord and plug belt grinders before servicng them, by unplugging it. Abatement Certification Required:
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2013-09-26
Current Penalty 1137.75
Initial Penalty 1517.0
Final Order 2013-10-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about 9/5/13/ employee was operating a belt grinder with the guard door in the open position, exposing employee hand to possible injuries from rotating wheel, nut and edge of sand paper. a) No Abatement required:
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 B04
Issuance Date 2013-09-26
Abatement Due Date 2013-10-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-10-02
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(4): If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. a) On or about 9/5/13, exits or exit dicharge were not immediately apparent, while standing in the heat treatment area. Abatement certification Required:
315502187 0213600 2011-07-19 7888 ROUTE 98, ARCADE, NY, 14009
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2011-10-07
Emphasis N: RKNEP
Case Closed 2012-07-23

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19040004 A
Issuance Date 2011-11-10
Abatement Due Date 2011-11-15
Initial Penalty 770.0
Contest Date 2011-12-01
Final Order 2012-05-25
Nr Instances 2
Nr Exposed 11
Gravity 00
Citation ID 01002
Citaton Type Other
Standard Cited 19040004 A
Issuance Date 2011-11-10
Abatement Due Date 2011-11-15
Initial Penalty 770.0
Contest Date 2011-12-01
Final Order 2012-05-25
Nr Instances 3
Nr Exposed 12
Gravity 00
Citation ID 01003
Citaton Type Other
Standard Cited 19040007 B03
Issuance Date 2011-11-10
Abatement Due Date 2011-11-15
Initial Penalty 770.0
Contest Date 2011-12-01
Final Order 2012-05-25
Nr Instances 1
Nr Exposed 10
Gravity 00
315178160 0213600 2011-01-05 7888 RT. 98, ARCADE, NY, 14009
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2011-01-05
Emphasis N: SSTARG10
Case Closed 2011-02-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2011-01-25
Abatement Due Date 2011-02-27
Current Penalty 2975.0
Initial Penalty 2975.0
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19100213 I01
Issuance Date 2011-01-25
Abatement Due Date 2011-02-27
Current Penalty 2975.0
Initial Penalty 2975.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2011-01-25
Abatement Due Date 2011-02-27
Current Penalty 2975.0
Nr Instances 1
Nr Exposed 2
Gravity 05
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100213 I01
Issuance Date 2011-01-25
Abatement Due Date 2011-02-27
Nr Instances 1
Nr Exposed 1
Gravity 05
310025341 0213600 2006-07-10 7888 ROUTE 98, ARCADE, NY, 14009
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2006-09-08
Emphasis N: SSTARG05
Case Closed 2006-11-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2006-09-18
Abatement Due Date 2006-10-23
Current Penalty 2500.0
Initial Penalty 2500.0
Nr Instances 6
Nr Exposed 2
Gravity 10
Hazard CRUSHING
Citation ID 01002
Citaton Type Serious
Standard Cited 19100106 E06 II
Issuance Date 2006-09-18
Abatement Due Date 2006-09-21
Current Penalty 525.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01003
Citaton Type Other
Standard Cited 19100146 C07 III
Issuance Date 2006-09-18
Abatement Due Date 2006-10-23
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 C07 IA
Issuance Date 2006-09-18
Abatement Due Date 2006-09-21
Current Penalty 2500.0
Initial Penalty 2500.0
Nr Instances 3
Nr Exposed 2
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2006-09-18
Abatement Due Date 2006-09-21
Current Penalty 2500.0
Initial Penalty 2500.0
Nr Instances 3
Nr Exposed 2
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19100124 G02
Issuance Date 2006-09-18
Abatement Due Date 2006-10-23
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19100141 G02
Issuance Date 2006-09-18
Abatement Due Date 2006-10-23
Nr Instances 4
Nr Exposed 4
Gravity 01
Citation ID 02003
Citaton Type Other
Standard Cited 19100146 C02
Issuance Date 2006-09-18
Abatement Due Date 2006-11-23
Nr Instances 3
Nr Exposed 1
Gravity 01
Citation ID 02004
Citaton Type Other
Standard Cited 19100147 C06 I
Issuance Date 2006-09-18
Abatement Due Date 2006-11-23
Nr Instances 1
Nr Exposed 2
Gravity 01

Date of last update: 31 Mar 2025

Sources: New York Secretary of State