345982110
|
0213600
|
2022-05-25
|
7888 ROUTE 98, ARCADE, NY, 14009
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-05-25
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-01-04
|
Related Activity
Type |
Referral |
Activity Nr |
1897734 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2022-09-16 |
Abatement Due Date |
2022-10-11 |
Current Penalty |
7000.0 |
Initial Penalty |
13052.0 |
Contest Date |
2022-10-12 |
Final Order |
2022-11-07 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) On or about 5/22/2022, in the Molding Department, employees were exposed to crush between hazards when working around the mold transfer shuttle. Employee's head got crushed between the mold transfer shuttle and support I beam when the shuttle was moving away from the machine as the employee was walking to the other side of the mold transfer shuttle. b) On or about 5/25/2022, in the Molding Department, employees were exposed to crush between hazards when working around the mold transfer shuttle. Employees are exposed to crush between hazards when the shuttle moves towards the machine, as it creates a pinch point between the I beam and the rear of the mold transfer shuttle. ABATEMENT DOCUMENTATION REQUIRED |
|
|
343173233
|
0213600
|
2018-05-18
|
7888 ROUTE 98, ARCADE, NY, 14009
|
|
Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-18
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2018-11-30
|
Related Activity
Type |
Accident |
Activity Nr |
1340138 |
|
Type |
Referral |
Activity Nr |
1338813 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100094 A04 I |
Issuance Date |
2018-10-29 |
Abatement Due Date |
2018-11-14 |
Current Penalty |
10348.0 |
Initial Penalty |
12934.0 |
Final Order |
2018-10-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.94(a)(4)(i): The construction, installation, inspection, and maintenance of exhaust systems shall conform to the principles and requirements set forth in American National Standard Fundamentals Governing the Design and Operation of Local Exhaust Systems, Z9.2-1960, and ANSI Z33.1-1961, which are incorporated by reference as specified in �� 1910.6. a) On or about 05/17/18, in the grinding department at TPI Arcade, located at 7888 Route 98 in Arcade, New York, the employer did not maintain, inspect or clean the duct work of the dust collection unit used to ventilate and filter exhaust from a Wheelabrator Blast Machine, to prevent the accumulation of 9,560 lbs. or 4.7 tons of steel shot particles and cause the duct pipe to collapse. Employees were exposed to fatal crushing injuries. b) On or about 05/17/18, in the grinding department at TPI Arcade, located at 7888 Route 98 in Arcade, New York, the employer did not install an appropriately designed local exhaust system that includes clean out ports to facilitate inspection and maintenance as required by ANSI Z9.2-1960. Employees were exposed to fatal crushing injuries. ABATEMENT DOCUMENTATION REQUIRED |
|
|
339378473
|
0213600
|
2013-09-05
|
7888 RT 98, ARCADE, NY, 14009
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-09-11
|
Emphasis |
N: SSTARG12, P: SSTARG12
|
Case Closed |
2013-10-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 A02 III A |
Issuance Date |
2013-09-26 |
Abatement Due Date |
2013-10-21 |
Current Penalty |
1338.75 |
Initial Penalty |
1785.0 |
Final Order |
2013-10-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(a)(2)(iii)(A): Work on cord and plug connected electric equipment for which exposure to the hazards of unexpected energization or start up of the equipment is controlled by the unplugging of the equipment from the energy source and by the plug being under the exclusive control of the employee performing the servicing or maintenance. a) On or about 9/5/13, employees did not de-energize cord and plug belt grinders before servicng them, by unplugging it. Abatement Certification Required: |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-09-26 |
Current Penalty |
1137.75 |
Initial Penalty |
1517.0 |
Final Order |
2013-10-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about 9/5/13/ employee was operating a belt grinder with the guard door in the open position, exposing employee hand to possible injuries from rotating wheel, nut and edge of sand paper. a) No Abatement required: |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 B04 |
Issuance Date |
2013-09-26 |
Abatement Due Date |
2013-10-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-10-02 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(4): If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. a) On or about 9/5/13, exits or exit dicharge were not immediately apparent, while standing in the heat treatment area. Abatement certification Required: |
|
|
315502187
|
0213600
|
2011-07-19
|
7888 ROUTE 98, ARCADE, NY, 14009
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2011-10-07
|
Emphasis |
N: RKNEP
|
Case Closed |
2012-07-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2011-11-10 |
Abatement Due Date |
2011-11-15 |
Initial Penalty |
770.0 |
Contest Date |
2011-12-01 |
Final Order |
2012-05-25 |
Nr Instances |
2 |
Nr Exposed |
11 |
Gravity |
00 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2011-11-10 |
Abatement Due Date |
2011-11-15 |
Initial Penalty |
770.0 |
Contest Date |
2011-12-01 |
Final Order |
2012-05-25 |
Nr Instances |
3 |
Nr Exposed |
12 |
Gravity |
00 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19040007 B03 |
Issuance Date |
2011-11-10 |
Abatement Due Date |
2011-11-15 |
Initial Penalty |
770.0 |
Contest Date |
2011-12-01 |
Final Order |
2012-05-25 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
00 |
|
|
315178160
|
0213600
|
2011-01-05
|
7888 RT. 98, ARCADE, NY, 14009
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-01-05
|
Emphasis |
N: SSTARG10
|
Case Closed |
2011-02-25
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2011-01-25 |
Abatement Due Date |
2011-02-27 |
Current Penalty |
2975.0 |
Initial Penalty |
2975.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100213 I01 |
Issuance Date |
2011-01-25 |
Abatement Due Date |
2011-02-27 |
Current Penalty |
2975.0 |
Initial Penalty |
2975.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2011-01-25 |
Abatement Due Date |
2011-02-27 |
Current Penalty |
2975.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100213 I01 |
Issuance Date |
2011-01-25 |
Abatement Due Date |
2011-02-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
|
310025341
|
0213600
|
2006-07-10
|
7888 ROUTE 98, ARCADE, NY, 14009
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-09-08
|
Emphasis |
N: SSTARG05
|
Case Closed |
2006-11-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-10-23 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
6 |
Nr Exposed |
2 |
Gravity |
10 |
Hazard |
CRUSHING |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 II |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-09-21 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100146 C07 III |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-10-23 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 IA |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-09-21 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-09-21 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100124 G02 |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-10-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100141 G02 |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-10-23 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100146 C02 |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-11-23 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2006-09-18 |
Abatement Due Date |
2006-11-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|