Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-08-14
|
Emphasis |
L: FALL
|
Case Closed |
2023-04-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1488239 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2020-02-12 |
Current Penalty |
700.0 |
Initial Penalty |
2892.0 |
Contest Date |
2020-02-18 |
Final Order |
2020-08-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 340 Blackheath Rd., Long Beach, NY- Employees were not wearing head protection while exposed to being struck by overhead materials such as, but not limited to hand tools and connecting hardware being used by workers overhead; on or about 8/14/20. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260760 B03 |
Issuance Date |
2020-02-12 |
Abatement Due Date |
2020-02-19 |
Current Penalty |
700.0 |
Initial Penalty |
2892.0 |
Contest Date |
2020-02-18 |
Final Order |
2020-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(b)(3): Each connector working at heights over 15 and up to 30 feet above a lower level, was not provided with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or was not provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section; a) Worksite, 340 Blackheath Rd., Long Beach, NY- One employee was working at a height of approximately 17 feet above the ground below while engaged in connecting steel beams without having the equipment necessary to be tied off; on or about 8/14/19. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2020-02-12 |
Current Penalty |
604.0 |
Initial Penalty |
2313.0 |
Contest Date |
2020-02-18 |
Final Order |
2020-08-21 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite, 340 Blackheath Rd., Long Beach, NY- Employees used an unsecured ladder to access an upper landing. The ladder siderails were not extended three feet above the upper landing; on or about 3/24/17. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2020-02-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2020-02-18 |
Final Order |
2020-08-21 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder. a) Worksite, 340 Blackheath Rd., Long Beach, NY- To access the main floor level of the structure the employees used an approximately nine foot ladder. The foot of the ladder was approximately four feet from the supporting structure; on or about 8/14/19. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19261053 B20 |
Issuance Date |
2020-02-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2020-02-18 |
Final Order |
2020-08-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(20): Employees did not face the ladder when ascending or descending the ladder: a) Worksite, 340 Blackheath Rd., Long Beach, NY- Employee was facing outward when he descended a nine foot job made ladder from the main floor to ground level; on or about 8/14/19. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
|