Name: | SUNSHINE CONTRACTING INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 04 Feb 2000 (25 years ago) |
Entity Number: | 2470027 |
ZIP code: | 11704 |
County: | Suffolk |
Place of Formation: | New York |
Address: | 217 BEDELL STREET, WEST BABYLON, NY, United States, 11704 |
Principal Address: | 217 BEDELL ST, WEST BABYLON, NY, United States, 11704 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
DAVID A BASILE | Chief Executive Officer | 217 BEDELL ST, WEST BABYLON, NY, United States, 11704 |
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 217 BEDELL STREET, WEST BABYLON, NY, United States, 11704 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
140324002428 | 2014-03-24 | BIENNIAL STATEMENT | 2014-02-01 |
120321002152 | 2012-03-21 | BIENNIAL STATEMENT | 2012-02-01 |
100322002261 | 2010-03-22 | BIENNIAL STATEMENT | 2010-02-01 |
080227002871 | 2008-02-27 | BIENNIAL STATEMENT | 2008-02-01 |
060302002776 | 2006-03-02 | BIENNIAL STATEMENT | 2006-02-01 |
040206002610 | 2004-02-06 | BIENNIAL STATEMENT | 2004-02-01 |
000204000500 | 2000-02-04 | CERTIFICATE OF INCORPORATION | 2000-02-04 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
1463301 | PL VIO | INVOICED | 2013-10-15 | 13300 | PL - Padlock Violation |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334913001 | 0214700 | 2012-06-28 | 697 JERUSALEM AVE., UNIONDALE, NY, 11553 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2012-08-16 |
Abatement Due Date | 2012-08-17 |
Current Penalty | 500.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-01-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 697 Jerusalem Ave. Uniondale, NY - Employees were not wearing protective helmets and were exposed to being struck by overhead materials and tools such as plywood and lumber, while walking below overhead work; on or about 06/28/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2012-08-16 |
Abatement Due Date | 2012-08-17 |
Current Penalty | 500.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-01-22 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite, 697 Jerusalem Ave. Uniondale, NY - Employees were exposed to falling approximately 20ft to the ground below while framing and sheathing the roof of a two story residential home. Employees were not trained to recognize the hazards associated with falling; on or about 06/28/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-08-16 |
Abatement Due Date | 2012-08-17 |
Current Penalty | 500.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-01-22 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) West side of home, 697 Jerusalem Ave. Uniondale, NY - Employees were using an extension ladder to access the roof of the home. The ladder was extended approximately 1 1/2ft above the landing; on or about 06/28/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B22 |
Issuance Date | 2012-08-16 |
Abatement Due Date | 2012-08-17 |
Current Penalty | 500.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-01-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) West side of home, 697 Jerusalem Ave. Uniondale, NY - Employee was carrying a 1/2 inch piece of plywood up an extension ladder approximately 20ft above the ground below; on or about 6/28/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 02001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2012-08-16 |
Abatement Due Date | 2012-08-17 |
Current Penalty | 3000.0 |
Initial Penalty | 11000.0 |
Final Order | 2013-01-22 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Worksite, 697 Jerusalem Ave. Uniondale, NY - Employee was installing plywood sheathing to the roof of a two story residential home. Employee was not provided with a means of fall protection and was exposed to a fall of approximately 20ft to the ground below; on or about 06/28/12. b) Worksite, 697 Jerusalem Ave. Uniondale, NY - Employee was installing rafters to the roof of a two story residential home while working on the edge of the building. The employee was not provided with a means of fall protection and was exposed to a fall of approximately 20ft to the ground below; on or about 06/28/12. |
Date of last update: 31 Mar 2025