Name: | AAR HOME IMPROVEMENTS CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 22 May 2000 (25 years ago) |
Entity Number: | 2512403 |
ZIP code: | 11793 |
County: | Nassau |
Place of Formation: | New York |
Address: | 2828 CHARLES ROAD, WANTAGH, NY, United States, 11793 |
Principal Address: | 2828 CHARLES RD, WANTAGH, NY, United States, 11793 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
C/O MICHAEL PIENKOS | DOS Process Agent | 2828 CHARLES ROAD, WANTAGH, NY, United States, 11793 |
Name | Role | Address |
---|---|---|
MICHAEL P PIENKOS JR | Chief Executive Officer | 2828 CHARLES RD, WANTAGH, NY, United States, 11793 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
020514002312 | 2002-05-14 | BIENNIAL STATEMENT | 2002-05-01 |
000522000156 | 2000-05-22 | CERTIFICATE OF INCORPORATION | 2000-05-22 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343587358 | 0216000 | 2018-11-07 | 1 COBB LANE, TARRYTOWN, NY, 10591 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1359843 |
Health | Yes |
Type | Referral |
Activity Nr | 1399011 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2019-01-15 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown; employees were working on a rooftop approximately 16 feet above ground level without any type of fall protection to include the use of a guardrail systems, safety net systems, or personal fall arrest systems. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B04 I |
Issuance Date | 2019-01-15 |
Current Penalty | 2772.0 |
Initial Penalty | 2772.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown; Employees working on a porch roof with multiple unprotected hole opening were exposed to a fall of 9 ft. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2019-01-15 |
Current Penalty | 2772.0 |
Initial Penalty | 2772.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown; Employees exposed to a fall from a roof and/or holes were not provided with fall protection training. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-01-15 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown The portable telescoping aluminum extension ladder did not extend 3ft above the landing. The ladder extended approximately 3 inches above the roof edge. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2019-01-15 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder was used for purposes other than the purpose for which it was designed. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown; Employee stood on the 3rd rung from top of ladder. The Ladder Instruction Manual and warning labels on ladder stated not to stand or step on any rung within 3 feet of the top of the ladder. |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2019-01-15 |
Current Penalty | 2772.0 |
Initial Penalty | 2772.0 |
Final Order | 2019-05-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. On or about November 7th, 2018, at 1 Cobb Lane in Tarrytown; Employees used a telescopic ladder improperly and ladder safety training was not provided. |
Date of last update: 31 Mar 2025