347266579
|
0215800
|
2024-02-08
|
1416 WILLIS AVENUE, SYRACUSE, NY, 13204
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-02-08
|
Emphasis |
N: RCS-NEP, P: RCS-NEP
|
Case Closed |
2024-07-19
|
Related Activity
Type |
Referral |
Activity Nr |
2125000 |
Health |
Yes |
|
|
347229437
|
0215800
|
2024-01-24
|
1416 WILLIS AVE., SYRACUSE, NY, 13204
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-01-24
|
Emphasis |
N: AMPUTATE
|
Related Activity
Type |
Complaint |
Activity Nr |
2121997 |
Safety |
Yes |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
2125000 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L03 |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-07 |
Current Penalty |
1244.4 |
Initial Penalty |
2074.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
7 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(3):Training program content. Powered industrial truck operators did not receive initial training in accordance with paragraph (l) of this section: a) On or about 1/24/2024, Production area: The employer did not provide powered industrial truck operators with initial training regarding operating instructions, warnings, and precautions for the types of truck the operator was authorized to operate. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 III |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-07 |
Current Penalty |
2074.2 |
Initial Penalty |
3457.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about 1/24/2024, Production area: The employer did not evaluate each powered industrial truck operator's performance at least once every 3 years. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-07 |
Current Penalty |
2488.8 |
Initial Penalty |
4148.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 1/24/2024, Process Area: The rotating wheel of a Makita Angle Grinder was not guarded. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-14 |
Current Penalty |
2074.2 |
Initial Penalty |
3457.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 1/24/2024, Production floor: The electrical cord for a Skyjack scissor lift was damaged, exposing internal wire components. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-07 |
Current Penalty |
1244.4 |
Initial Penalty |
2074.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 1/24/2024, Exterior of the Facility: An extension cord was being used to power a Mirabito Fuel Tank. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2024-07-19 |
Abatement Due Date |
2024-08-07 |
Current Penalty |
0.0 |
Initial Penalty |
2074.0 |
Final Order |
2024-08-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were used and run through holes in walls, ceilings, or floors: a) On or about 1/24/2024, Maintenance Area: An extension cord used to power a Mirabito fuel tank was run through a hole in the wall and plugged into an outlet. |
|
|
339841827
|
0215800
|
2014-07-09
|
1416 WILLIS AVE., SYRACUSE, NY, 13204
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-07-09
|
Case Closed |
2014-07-09
|
Related Activity
Type |
Inspection |
Activity Nr |
901184 |
Health |
Yes |
|
|
339011843
|
0215800
|
2013-04-18
|
1416 WILLIS AVE., SYRACUSE, NY, 13204
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-05-01
|
Case Closed |
2014-05-09
|
Related Activity
Type |
Complaint |
Activity Nr |
812927 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100145 F05 |
Issuance Date |
2013-07-02 |
Abatement Due Date |
2013-08-07 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-08-30 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.145(f)(5): Danger tags were not used where an immediate hazard presented a threat of death or serious injury to employees: a) Steel mezzanine, on or about 6/27/13: Danger tags or warning signs were not posted warning employees to stay away from area under mezzanine because of structural instability. The area was not cordoned off. b) Loading dock area, on or about 6/27/13: Danger tags or warning signs were not posted warning employees to stay away from loading dock walls due to structural instability and vibration from tractor trailer use. The area was not cordoned off. c) Hallway from break room to maintenance shop, on or about 6/27/13: Danger tags or warning signs were not posted warning employees not to enter hallway because of unstable steel push wall. The area was not cordoned off. Abatement cerification must be submitted for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2013-07-02 |
Current Penalty |
714.0 |
Initial Penalty |
1020.0 |
Final Order |
2013-08-30 |
Nr Instances |
110 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Throughout the facility, on or about 4/18/13: An eyewash was not provided for employees that work with Cement Kiln Dust, a corrosive additive used in making animal bedding. Abatement certification must be submitted for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2013-07-02 |
Current Penalty |
714.0 |
Initial Penalty |
1020.0 |
Final Order |
2013-08-30 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Throughout the facility, on or about 4/18/13: Information and training on the hazards of chemicals used in the work place was not provided for employees that work with hazardous materials including, but not limited to, Cement Kiln Dust, a corrosive additive used in making animal bedding. Abatement certification must be submitted for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2013-07-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-30 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Throughout the facility, on or about 4/18/13: Energy control procedures were not developed for the equipment used in mixing Cement Kiln Dust and wood. The equipment includes walking in-feed floor conveyor, hammer mill, auger, screw trough and out-feed belt conveyor. Abatement certification must be submitted for thir item. |
|
|
306312901
|
0215800
|
2003-11-13
|
1416 WILLIS AVENUE, SYRACUSE, NY, 13204
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2003-11-13
|
Case Closed |
2003-11-13
|
Related Activity
Type |
Inspection |
Activity Nr |
306309451 |
|
|
306309451
|
0215800
|
2003-06-12
|
1416 WILLIS AVENUE, SYRACUSE, NY, 13204
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2003-09-09
|
Case Closed |
2004-10-27
|
Related Activity
Type |
Accident |
Activity Nr |
100881143 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
Hazard |
STRUCK BY |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
Hazard |
LIFTING |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-29 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100023 C02 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-29 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100145 C03 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
560.0 |
Initial Penalty |
800.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
02 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100304 F04 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
700.0 |
Initial Penalty |
1000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01010 |
Citaton Type |
Serious |
Standard Cited |
19100305 A01 I |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
01 |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Nr Instances |
4 |
Nr Exposed |
8 |
Gravity |
01 |
|
Citation ID |
02001C |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2003-10-16 |
Abatement Due Date |
2003-10-21 |
Nr Instances |
8 |
Nr Exposed |
8 |
Gravity |
01 |
|
|