Search icon

NORTHEAST CONSTRUCTION INDUSTRIES, INC.

Company Details

Name: NORTHEAST CONSTRUCTION INDUSTRIES, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 09 Aug 2000 (25 years ago)
Date of dissolution: 08 Apr 2021
Entity Number: 2540352
ZIP code: 12549
County: Orange
Place of Formation: New York
Address: ROBERT SCHROEDER, JR, 657 ROUTE 17K, MONTGOMERY, NY, United States, 12549
Principal Address: 657 ROUTE 17K, MONTGOMERY, NY, United States, 12549

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
ROBERT SCHROEDER, JR Chief Executive Officer 657 ROUTE 17K, MONTGOMERY, NY, United States, 12549

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent ROBERT SCHROEDER, JR, 657 ROUTE 17K, MONTGOMERY, NY, United States, 12549

History

Start date End date Type Value
2013-11-22 2014-05-16 Address ROBERT SCHROEDER, JR., 255 RT. 17K, LOWER LEVEL, NEWBURGH, NY, 12550, USA (Type of address: Service of Process)
2013-11-07 2014-04-08 Address 255 RTE 17K, LOWER LEVEL, NEWBURGH, NY, 12550, USA (Type of address: Principal Executive Office)
2013-11-07 2014-04-08 Address 255 RTE 17K, LOWER LEVEL, NEWBURGH, NY, 12550, USA (Type of address: Chief Executive Officer)
2012-08-21 2013-11-07 Address 735 SOUTH STREET / SUITE 2, NEWBURGH, NY, 12550, USA (Type of address: Principal Executive Office)
2012-08-21 2013-11-07 Address 735 SOUTH STREET / SUITE 2, NEWBURGH, NY, 12550, USA (Type of address: Chief Executive Officer)
2012-08-21 2013-11-22 Address 735 SOUTH STREET / SUITE 2, NEWBURGH, NY, 12550, USA (Type of address: Service of Process)
2010-05-10 2012-08-21 Address 735 SOUTH ST, STE 2, NEWBURGH, NY, 12550, USA (Type of address: Principal Executive Office)
2010-05-10 2012-08-21 Address 735 SOUTH ST, STE 2, NEWBURGH, NY, 12550, USA (Type of address: Chief Executive Officer)
2010-05-10 2012-08-21 Address 735 SOUTH ST, STE 2, NEWBURGH, NY, 12550, USA (Type of address: Service of Process)
2004-09-21 2010-05-10 Address 2424 ROUTE 32 / SUITE 103, NEW WINDSOR, NY, 12553, USA (Type of address: Principal Executive Office)

Filings

Filing Number Date Filed Type Effective Date
210408000055 2021-04-08 CERTIFICATE OF DISSOLUTION 2021-04-08
140516000389 2014-05-16 CERTIFICATE OF AMENDMENT 2014-05-16
140408002416 2014-04-08 AMENDMENT TO BIENNIAL STATEMENT 2012-08-01
131122000579 2013-11-22 CERTIFICATE OF AMENDMENT 2013-11-22
131107002042 2013-11-07 BIENNIAL STATEMENT 2012-08-01
120821002202 2012-08-21 BIENNIAL STATEMENT 2012-08-01
100909002645 2010-09-09 BIENNIAL STATEMENT 2010-08-01
100510002016 2010-05-10 BIENNIAL STATEMENT 2008-08-01
040921002062 2004-09-21 BIENNIAL STATEMENT 2004-08-01
020814002249 2002-08-14 BIENNIAL STATEMENT 2002-08-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340911361 0213100 2015-09-11 657 ROUTE 17K, MONTGOMERY, NY, 12549
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2015-12-18
Case Closed 2016-02-26

Related Activity

Type Referral
Activity Nr 1014883
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2016-01-29
Abatement Due Date 2016-03-03
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2016-02-26
Nr Instances 1
Nr Exposed 11
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A) Worksite - On or about September 11, 2015, the employer did not develop, implement, and maintain a written hazard communication program to protect employees from the hazards associated with chemicals such as, but not limited to: propane, Densglass, and different types of paint.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2016-01-29
Abatement Due Date 2016-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-26
Nr Instances 1
Nr Exposed 11
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical. A) Worksite - On or about September 11, 2015, the employer did not maintain safety data sheets (SDSs) for each hazardous chemical such as, but not limited to: propane, Densglass, and different types of paint.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2016-01-29
Abatement Due Date 2016-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-26
Nr Instances 1
Nr Exposed 11
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: A) Worksite - On or about September 11, 2015, the employer did not provide training on the hazards of each hazardous chemical such as, but not limited to: propane, Densglass, and different types of paint.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2016-01-29
Abatement Due Date 2016-03-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-02-26
Nr Instances 1
Nr Exposed 10
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: A) Worksite - On or about September 11, 2015, employees were provided with N95 filtering facepiece respirators for voluntary use. Employees were not provided with the information in Appendix D.
340875210 0213100 2015-08-26 657 ROUTE 17K, MONTGOMERY, NY, 12549
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-12-18
Case Closed 2020-01-24

Related Activity

Type Complaint
Activity Nr 1012613
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2015-12-22
Current Penalty 780.0
Initial Penalty 1200.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Main production building - On or before August 26, 2015 all employees were not issued safety glasses for tasks, including but not limited, to using a power saw to cut a fiberglass type material for wall panels.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100136 A
Issuance Date 2015-12-22
Current Penalty 1040.0
Initial Penalty 1600.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.136(a): The employer did not ensure that each protected employee used protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects: a) Employer's main production building - On or before August 26, 2015, employees were not wearing protective footwear while exposed to the possibility of falling objects when assisting moving wall panel sections being moved by a forklift.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2015-12-22
Current Penalty 1560.0
Initial Penalty 2400.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) The employer used a propane powered industrial truck in the facility and did not have any training or evaluation program for drivers who used this forklift.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100178 L06
Issuance Date 2015-12-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) The employer used a propane powered industrial truck in the facility and did not have any training or evaluation program for drivers who used this forklift. Accordingly, drivers were operating forklifts without proper certification.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100178 Q06
Issuance Date 2015-12-22
Current Penalty 1560.0
Initial Penalty 2400.0
Final Order 2016-01-06
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(6): Industrial trucks shall not be altered so that the relative positions of the various parts are different from what they were when originally received from the manufacturer, nor shall they be altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts, except as provided in paragraph (q)(12) of this section. Additional counterweighting of fork trucks shall not be done unless approved by the truck manufacturer: a) Main production facility - On or before August 26, 2015, a propane powered Clark forklift was in operation with an attachment that had not been approved by the manufacturer by means of letter or affixed label. The attachments was a man lift that had been hand crafted from a pallet and some light gauge steel railing. No serial numbers or make information on it. b) Main production facility - On or before August 26, 2015, a propane powered Clark forklift was in operation with an attachment that had not been approved by the manufacturer by means of letter or affixed label. The attachment was a boom with a further attachment for moving wall panels once the panels were constructed.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100178 Q07
Issuance Date 2015-12-22
Current Penalty 1560.0
Initial Penalty 2400.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) Main production facility - On or before August 26, 2015, a propane powered Clark forklift was not inspected prior to being placed in operation for each shift that it was used.
Citation ID 02001
Citaton Type Other
Standard Cited 19040004 A
Issuance Date 2015-12-22
Abatement Due Date 2016-01-05
Current Penalty 0.0
Initial Penalty 400.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.4(a): The employer did not record on the OSHA Form 300 or equivalent each work-related fatality, injury, or illness case that resulted in the general recording criteria: a) Employer's Office - On or about July 17, 2105 an employee received a laceration to the head when struck by sheet metal strapping and received hospital medical treatment. This injury where the employee received stitches was not recorded in the injury and illnesses log because the employer was not keeping this log.
Citation ID 02002
Citaton Type Other
Standard Cited 19100138 A
Issuance Date 2015-12-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-01-06
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion: a) Main Production building - On or before August 26, 2015, some employees were not issued gloves despite cutting and handling fiberglass type material for wall panels.
334863784 0213100 2012-06-25 735 SOUTH STREET, SUITE 2, NEWBURGH, NY, 12550
Inspection Type Planned
Scope NoInspection
Safety/Health Health
Close Conference 2012-06-25
Emphasis N: PMETALS
Case Closed 2012-06-27

Date of last update: 30 Mar 2025