OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339970758 0215000 2014-09-26 719 AVENUE J, BROOKLYN, NY, 11230
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2014-09-26
Case Closed 2014-10-01

Related Activity

Type Inspection
Activity Nr 913022
Safety Yes
339130221 0215000 2013-06-20 719 AVENUE J, BROOKLYN, NY, 11230
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2013-06-20
Emphasis L: FALL
Case Closed 2018-10-22

Related Activity

Type Referral
Activity Nr 825015
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2013-07-19
Abatement Due Date 2013-08-07
Current Penalty 3080.0
Initial Penalty 3080.0
Final Order 2013-12-18
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. Location: 719 Avenue J Brooklyn, NY On or about 06/20/13 a) Employees were not trained to recognize fall hazards. Five employees were working by the edge of a roof without any fall protection while exposed to a potential fall of approximately 20 feet to ground below.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2013-07-19
Current Penalty 6160.0
Initial Penalty 6160.0
Final Order 2013-12-18
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Location: 719 Avenue J Brooklyn, NY / Roof On or about 06/20/13 a) Five employees were working on a steep roof without fall protection while exposed to a potential fall of approximately 20 feet to the ground below. ISLAND EXTERIORS, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 1926.501(b)(13)WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313432171 CITATION NUMBER 01, ITEM NUMBER 002, ISSUE ON 09/30/2011. NOTE: FINAL ORDER DATE 02/06/12
335145389 0215600 2012-06-26 61-30 TO 61-24 64TH AVENUE, OAKLAND GARDENS, NY, 11364
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2012-06-27
Case Closed 2018-02-08

Related Activity

Type Inspection
Activity Nr 515200
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-12-10
Abatement Due Date 2013-01-29
Current Penalty 2000.0
Initial Penalty 2000.0
Contest Date 2012-12-28
Final Order 2013-09-16
Nr Instances 4
Nr Exposed 11
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On or before June 26, 2012Job site at Bayhill Gardens 61-26 64th ave, Oakland Gardens NY 11364 b) On or before June 27, 2012Job site at Bayhill Gardens 61-34 64th ave, Oakland Gardens NY 11364 c) On or before July 13, 2012Job site at Bayhill Gardens 223 Place between 64 ave and 69 ave, Oakland Gardens NY 11364 b) On or before August 17, 2012Job site at Bayhill Gardens 223 Place between 64 ave and 65 ave, Oakland Gardens NY 11364 Employees were exposed to overhead hazards from 10-feet to 30-feet without heard hats. WRITTEN ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2012-12-10
Current Penalty 2000.0
Initial Penalty 2000.0
Contest Date 2012-12-28
Final Order 2013-09-16
Nr Instances 1
Nr Exposed 11
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) On or before June 26, 2012Job site at Bayhill Gardens 61-26 64th ave, Oakland Gardens NY 11364 Employees exposed to electrical hazards from damaged flexible cord set. WRITTEN ABATEMENT DOCUMENTATION IS NOTREQUIRED PURSUANT TO CFR 1903.19.
Citation ID 01003
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2012-12-10
Current Penalty 5600.0
Initial Penalty 5600.0
Contest Date 2012-12-28
Final Order 2013-09-16
Nr Instances 4
Nr Exposed 11
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On or before June 26, 2012Job site at Bayhill Gardens 61-26 64th ave, Oakland Gardens NY 11364 b) On or before June 27, 2012Job site at Bayhill Gardens 61-34 64th ave, Oakland Gardens NY 11364 c) On or before July 13, 2012Job site at Bayhill Gardens 223 street between 64 ave and 69 ave, Oakland Gardens NY 11364 d) On or before August 17, 2012Job site at Bayhill Gardens 223 Place between 64 ave and 65 ave, Oakland Gardens NY 11364 Employees were exposed to overhead hazards from 10-feet to 30-feet without fall protection. THE ISLAND EXTERIORS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDERD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313432171, CITATION NUMBER 01, ITEM NUMBER 002, ISSUED ON 09/30/2011 WHICH BECAME A FINAL ORDER DATE ON 02/06/2012. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO CFR 1903.19.
313432171 0215600 2011-09-02 68-42 CLOVERDALE AVENUE, OAKLAND GARDENS, NY, 11364
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-09-02
Case Closed 2016-02-29

Related Activity

Type Referral
Activity Nr 200837318
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2012-01-03
Abatement Due Date 2012-01-06
Current Penalty 1800.0
Initial Penalty 1800.0
Nr Instances 4
Nr Exposed 4
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-01-03
Abatement Due Date 2012-01-06
Current Penalty 3000.0
Initial Penalty 3000.0
Nr Instances 1
Nr Exposed 4
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-01-03
Abatement Due Date 2012-01-06
Current Penalty 1800.0
Initial Penalty 1800.0
Nr Instances 1
Nr Exposed 4
Gravity 01
Citation ID 02001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2012-01-03
Abatement Due Date 2012-01-06
Nr Instances 1
Nr Exposed 4
Gravity 01
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2012-01-03
Abatement Due Date 2012-01-27
Nr Instances 1
Nr Exposed 4
Citation ID 02001C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2012-01-03
Abatement Due Date 2012-01-27
Nr Instances 1
Nr Exposed 4