339098881
|
0213100
|
2013-05-31
|
SARATOGA HERITAGE APARTMENTS, GANSEVOORT, NY, 12831
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-31
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2013-07-16
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260021 B02 |
Issuance Date |
2013-06-20 |
Current Penalty |
0.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a) Jobsite, Saratoga Heritage Apartments- On or about 05/31/13- Employer failed to instruct employees in the recognition and elimination of eye injury struck-by hazards when operating pneumatic nail guns. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260095 A |
Issuance Date |
2013-06-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Jobsite, Saratoga Heritage Apartments- on or about 05/31/12- Employees not wearing protective safety eyewear and using pneumatic nail guns were exposed to eye injury struck-by hazards. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19261053 B04 |
Issuance Date |
2013-06-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Jobsite, Saratoga Heritage Apartments- On or about 05/31/12- A-frame step ladder was not opened and propped against a wall to nail on exterior sheathing. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19261060 A |
Issuance Date |
2013-06-20 |
Abatement Due Date |
2013-07-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) Jobsite, Saratoga Heritage Apartments- On or 05/31/13- Employee exposed to a fall hazard when using a self-supported ladder propped against a wall was not trained in the propper use of the ladder. |
|
|
336470380
|
0213100
|
2012-09-19
|
RIDGE VIEW BUILDING 1 23 NORTHERN PINES ROAD, GANSEVOORT, NY, 12831
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-09-19
|
Emphasis |
L: FALL
|
Case Closed |
2013-01-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 III |
Issuance Date |
2012-11-27 |
Current Penalty |
1360.0 |
Initial Penalty |
1700.0 |
Final Order |
2012-12-19 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(iii): The employer did not ensure that each employee was trained as necessary by a competent person in the use and operation of personal fall arrest systems: a) Ridge View Building 1 - On or about 19 September, 2012 - Employees were installing roof trusses on the building without properly wearing attached personal fall protection. Employees were exposed to a fall hazard of 30 feet. b) Ridge View Building 1 - On or about 19 September, 2012 - Employees were installing roof trusses on the building and not enough anchor points were installed to protect each employee. Employees were exposed to a fall hazard of 30 feet. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19261052 C01 I |
Issuance Date |
2012-11-27 |
Abatement Due Date |
2012-12-07 |
Current Penalty |
0.0 |
Initial Penalty |
1020.0 |
Final Order |
2012-12-19 |
Nr Instances |
2 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:Note: 29 CFR 1926.1052(c)(7) applies when the top edge of a stairrail system also serves as a handrail. a) Ridge View Building 1 - On or about 19 September, 2012 - Employees were utilizing a stairway to access the first through third floors that was not equipped with at least one handrail. Employees were exposed to a fall hazard of 12 feet. |
|
|
332428721
|
0213100
|
2012-02-22
|
RIDGE VIEW, BUILDING 3 23 NORTHERN PINES, GANSEVOORT, NY, 12831
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-02-22
|
Emphasis |
L: FALL
|
Case Closed |
2012-04-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2012-03-07 |
Current Penalty |
0.0 |
Initial Penalty |
2550.0 |
Final Order |
2012-03-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of 1926.502(k) developed and implemented: a) Building - on or about December 22, 2011 - employees were installing roof sheeting on a 6 on 12 pitched roof without conventional fall protection. Ground to eave elevation was approximately 30 feet. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2012-03-07 |
Current Penalty |
1300.0 |
Initial Penalty |
2167.5 |
Final Order |
2012-03-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet or more above lower levels and the inside bottom edge of the wall opening, was not protected from falling by the use of a guardrail system, a sfaety net system or a personal fall arrest system: a) Third Story Floor, Center of Building - on or about December 22, 2011 - the guardrail system at the elevator shaft was not equipped with a midrail. Elevation to the concrete slab was approximately 25 feet. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2012-03-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-03-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least21 inches (53 cm) high: a) Third Story Floor, Center of Building - on or about December 22, 2011 - the guardrail system at the elevator shaft was not equipped with a midrail. Elevation to the concrete slab was approximately 25 feet. |
|
|