Search icon

PURE PERFORMANCE GROUP, INC.

Company Details

Name: PURE PERFORMANCE GROUP, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 08 Feb 2001 (24 years ago)
Entity Number: 2604136
ZIP code: 12110
County: Albany
Place of Formation: New York
Address: 881 Old Albany Shaker Road, Latham, NY, United States, 12110
Principal Address: 4 FREAR AVE, TROY, NY, United States, 12180

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE PURE PERFORMANCE GROUP, INC. DOS Process Agent 881 Old Albany Shaker Road, Latham, NY, United States, 12110

Chief Executive Officer

Name Role Address
JEREMY PURICK Chief Executive Officer 881 OLD ALBANY SHAKER ROAD, LATHAM, NY, United States, 12110

History

Start date End date Type Value
2025-02-27 2025-02-27 Address 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188, USA (Type of address: Chief Executive Officer)
2025-02-27 2025-02-27 Address 881 OLD ALBANY SHAKER ROAD, LATHAM, NY, 12110, USA (Type of address: Chief Executive Officer)
2015-12-10 2025-02-27 Address 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188, USA (Type of address: Chief Executive Officer)
2007-10-22 2015-12-10 Address 4 FREAR AVE, TROY, NY, 12180, USA (Type of address: Principal Executive Office)
2007-10-22 2015-12-10 Address 15 LOWER HUDSON AVE, GREEN ISLAND, NY, 12183, USA (Type of address: Chief Executive Officer)
2005-04-13 2007-10-22 Address NONE, NONE, 00000, YYY (Type of address: Principal Executive Office)
2005-04-13 2007-10-22 Address 14 ROCKEFFELER BLVD, RENSSELAER, NY, 12144, USA (Type of address: Chief Executive Officer)
2005-04-13 2025-02-27 Address 15 LOWER HUDSON AVE, GREEN ISLAND, NY, 12183, USA (Type of address: Service of Process)
2003-03-21 2005-04-13 Address 38 JUSTINE COURT, RENSSELAER, NY, 12144, USA (Type of address: Chief Executive Officer)
2003-03-21 2005-04-13 Address 4 FREAR AVE, TROY, NY, 12180, USA (Type of address: Principal Executive Office)

Filings

Filing Number Date Filed Type Effective Date
250227004269 2025-02-27 BIENNIAL STATEMENT 2025-02-27
220318001357 2022-03-18 BIENNIAL STATEMENT 2021-02-01
151210002022 2015-12-10 BIENNIAL STATEMENT 2015-02-01
071022002513 2007-10-22 BIENNIAL STATEMENT 2007-02-01
071018000345 2007-10-18 CERTIFICATE OF AMENDMENT 2007-10-18
050413002356 2005-04-13 BIENNIAL STATEMENT 2005-02-01
030321002787 2003-03-21 BIENNIAL STATEMENT 2003-02-01
010208000949 2001-02-08 CERTIFICATE OF INCORPORATION 2001-02-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340934728 0213100 2015-09-22 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-09-22
Case Closed 2015-09-22

Related Activity

Type Complaint
Activity Nr 1019576
Health Yes
340934850 0213100 2015-09-22 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2015-09-22
Case Closed 2015-09-22

Related Activity

Type Inspection
Activity Nr 1008899
Health Yes
340934934 0213100 2015-09-22 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-09-22
Case Closed 2015-09-22

Related Activity

Type Inspection
Activity Nr 1002832
Safety Yes
340088996 0213100 2014-11-18 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2014-11-18
Emphasis N: LEAD
Case Closed 2015-02-18

Related Activity

Type Referral
Activity Nr 920448
Health Yes
Type Inspection
Activity Nr 1002832
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-12-29
Abatement Due Date 2015-02-01
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) On and before 11/21/2014, at facility, for the welder working with hazardous chemicals such as, but not limited to, welding fumes. Employer did not provide a hazard communication program.
Citation ID 01001B
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-12-29
Abatement Due Date 2015-02-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On and before 11/21/2014, at facility, for the welder working with hazardous chemicals such as, but not limited to, welding fumes. Employees were not provided with information and training on the hazards of the chemicals they work with or are exposed to in their work area.
Citation ID 01001C
Citaton Type Other
Standard Cited 19101200 H03 IV
Issuance Date 2014-12-29
Abatement Due Date 2015-02-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information: (a) On and before 11/21/2014, at facility, for the welder working with hazardous chemicals such as, but not limited to, welding fumes. Employees were not provided with information and training on the hazards of the chemicals they work with or are exposed to in their work area.
340028323 0213100 2014-10-23 56 HUDSON RIVER ROAD, WATERFORD, NY, 12188
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-12-12
Emphasis N: AMPUTATE
Case Closed 2015-03-03

Related Activity

Type Inspection
Activity Nr 1008899
Health Yes
Type Complaint
Activity Nr 916196
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2014-12-29
Abatement Due Date 2015-01-26
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Machine Shop - On or about October 22, 2014, for the employees that use machinery, including but not limited to, the three Haas Computer Numerical Control (CNC) machines, lathes, a mill, and a hydraulic press. The employer did not establish an overall program consisting of an energy control procedure, employee training and periodic inspections which was needed to ensure that before any employee performed any servicing or maintenance on these machines or other machines in the shop that the unexpected energizing, startup or release of stored energy would not occur and cause injury.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2014-12-29
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about October 22, 2014 an employee was operating a Enco Vertical Manual Mill in a machine shop at 56 Hudson River Road, Waterford, NY 12188 which was not guarded at the point of operation.
Citation ID 01004
Citaton Type Other
Standard Cited 19100212 B
Issuance Date 2014-12-29
Abatement Due Date 2015-01-26
Current Penalty 0.0
Initial Penalty 1600.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about October 22, 2014 the employer was operating a Enco Vertical Manual Mill in a machine shop at 56 Hudson River Road, Waterford, NY 12188 and did not have it securely anchored to prevent walking or moving. b) On or about October 22, 2014 the employer was operating a Arcan Model P50 Hydraulic Press in a machine shop at 56 Hudson River Road, Waterford, NY 12188 and did not have it securely anchored to prevent walking or moving.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100303 B07 III
Issuance Date 2014-12-29
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(iii): Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, may not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues: a) Machine Shop - On or about October 22, 2014 an energized ENCO 038-0232 lathe had a damaged flexible cord near the plug.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-12-29
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-02-23
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about October 22, 2014 an employee was operating a Enco ENCO111-1445 lathe serial number 060641 in a machine shop at 56 Hudson River Road, Waterford, NY 12188 without adequate guarding to protect the employee from rotating parts and the point of operation. b) On or about October 22, 2014 an employee was operating a Enco ENCO111-1445 lathe serial number 991503 machinery in a machine shop at 56 Hudson River Road, Waterford, NY 12188 without adequate guarding to protect the employee from rotating parts and the point of operation. c) On or about October 22, 2014 a ENCO 308-0232 lathe no serial number was reported to be periodically in use at a machine shop at 56 Hudson River Road, Waterford, NY 12188 without adequate guarding to protect the employee from rotating parts and the point of operation.

Date of last update: 30 Mar 2025

Sources: New York Secretary of State