Search icon

JF CONSTRUCTION INC.

Company Details

Name: JF CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 08 Mar 2001 (24 years ago)
Date of dissolution: 16 Nov 2005
Entity Number: 2613664
ZIP code: 11355
County: Queens
Place of Formation: New York
Address: 133-36 41ST ROAD, FLUSHING, NY, United States, 11355

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 133-36 41ST ROAD, FLUSHING, NY, United States, 11355

Filings

Filing Number Date Filed Type Effective Date
051116000446 2005-11-16 CERTIFICATE OF DISSOLUTION 2005-11-16
010308000139 2001-03-08 CERTIFICATE OF INCORPORATION 2001-03-08

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
1904277 TRUSTFUNDHIC INVOICED 2014-12-05 200 Home Improvement Contractor Trust Fund Enrollment Fee
1904278 RENEWAL INVOICED 2014-12-05 100 Home Improvement Contractor License Renewal Fee
1758118 TRUSTFUNDHIC INVOICED 2014-08-12 200 Home Improvement Contractor Trust Fund Enrollment Fee
1758117 LICENSE INVOICED 2014-08-12 50 Home Improvement Contractor License Fee
1758148 FINGERPRINT INVOICED 2014-08-12 75 Fingerprint Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340871284 0215600 2015-08-25 184-21 AVON ROAD, JAMAICA, NY, 11432
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-08-25
Emphasis L: FALL
Case Closed 2017-01-04

Related Activity

Type Referral
Activity Nr 1013793
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2015-09-03
Current Penalty 1680.0
Initial Penalty 2800.0
Contest Date 2015-12-04
Final Order 2016-02-08
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about August 25, 2015- job site at 184-21 Avon Road, Jamaica, NY 11432 the employer permitted employees to work on a scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-12-04
Final Order 2016-02-08
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about August 25, 2015- job site at 184-21 Avon Road, Jamaica, NY 11432 the employer permitted employees to work on a tubular welded frame scaffold whose footing was sinking into the soft ground. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-12-04
Final Order 2016-02-08
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) On or about August 25, 2015- job site at 184-21 Avon Road, Jamaica, NY 11432 the employer permitted employees to access the working platform of a tubular welded frame scaffold by climbing the cross braces. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2015-09-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2015-12-04
Final Order 2016-02-08
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would automatically square: a) On or about August 25, 2015- job site at 184-21 Avon Road, Jamaica, NY 11432 the employer permitted employees to work on a tubular welded frame scaffold that did not have all of the required cross bracing. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-09-03
Current Penalty 1680.0
Initial Penalty 2800.0
Contest Date 2015-12-04
Final Order 2016-02-08
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) On or about August 25, 2015- job site at 184-21 Avon Road, Jamaica, NY 11432 the employer permitted employees to work on a scaffold, from 15-20 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
340478791 0215600 2015-03-19 179-15 80TH ROAD, JAMAICA, NY, 11432
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2015-03-19
Emphasis L: FALL
Case Closed 2016-04-07

Related Activity

Type Referral
Activity Nr 970593
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-03-26
Abatement Due Date 2015-04-03
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-04-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A). On or about 03/19/15, at 179-15 80th Road. Jamaica, NY Employees working on west side of the fabricated frame scaffolds of the house were exposed to the hazard of falling approximately 24 ft. to the ground. The working platforms were installed with only two scaffold planks. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2015-03-26
Abatement Due Date 2015-04-03
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2015-04-21
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs g(1)(i) through g(1)(vi) of this section, each employee working on a scaffold more than 10 above a lower level was not protected from falling to that lower level by the use of guardrails or personal fall arrest systems: A). on or about 03/19/15, scaffolds in west side of the house at 179-15 80th Road. Jamaica, NY Employees installing insulation paper around the window on the scaffolds were exposed to the hazard of falling approximately 24 ft. to the ground. Guardrails or personal fall arrest systems were not provided. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.

Date of last update: 30 Mar 2025

Sources: New York Secretary of State