Search icon

G.J.S. ELECTRIC, LLC

Company Details

Name: G.J.S. ELECTRIC, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 12 Mar 2001 (24 years ago)
Entity Number: 2615185
ZIP code: 11952
County: Suffolk
Place of Formation: New York
Address: 6615 MAIN RD, MATTITUCK, NY, United States, 11952

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 6615 MAIN RD, MATTITUCK, NY, United States, 11952

History

Start date End date Type Value
2001-03-12 2005-03-18 Address 2120 CROWN LAND LANE, CUTCHOGUE, NY, 11935, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
190311061105 2019-03-11 BIENNIAL STATEMENT 2019-03-01
170303006219 2017-03-03 BIENNIAL STATEMENT 2017-03-01
150420006124 2015-04-20 BIENNIAL STATEMENT 2015-03-01
130307006655 2013-03-07 BIENNIAL STATEMENT 2013-03-01
110321002213 2011-03-21 BIENNIAL STATEMENT 2011-03-01
090226002862 2009-02-26 BIENNIAL STATEMENT 2009-03-01
070227002208 2007-02-27 BIENNIAL STATEMENT 2007-03-01
050318002503 2005-03-18 BIENNIAL STATEMENT 2005-03-01
030224002091 2003-02-24 BIENNIAL STATEMENT 2003-03-01
010507000559 2001-05-07 AFFIDAVIT OF PUBLICATION 2001-05-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340205095 0214700 2015-01-23 137 DUNE RD., WESTHAMPTON BEACH, NY, 11978
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-01-23
Case Closed 2015-02-23

Related Activity

Type Inspection
Activity Nr 1020475
Safety Yes
Type Inspection
Activity Nr 1021743
Safety Yes
Type Inspection
Activity Nr 1021147
Safety Yes
Type Inspection
Activity Nr 992353
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2015-02-17
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite: Employees were carrying tools and materials from the first floor to the second floor of the residential building and were exposed to falls from an unprotected side approximately 9 ft. above the ground; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260502 B02
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2015-02-17
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) Worksite: Employees carrying tools and materials from the basement to the first floor were using a walking/working surface that did not have intermediate structural members installed between the top edge of the guardrail system and the walking/working surface and were exposed to falls of up to and including approximately 9 ft.; on or about 1/23/15. b) Worksite: Employees carrying tools and materials from the first floor to the second floor were using a walking/working surface that did not have intermediate structural members installed between the top edge of the guardrail system and the walking/working surface and were exposed to falls of up to and including approximately 18 ft.; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2015-02-03
Abatement Due Date 2015-02-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-17
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a) Worksite: Employees carrying tools and materials from the basement to the first floor were using stairs that were not provided with intermediate structural members and were exposed to falls of up to and including approximately 9 ft.; on or about 1/23/15. b) Worksite: Employees carrying tools and materials from the first floor to the second floor were using stairs that were not provided with intermediate structural members and were exposed to falls of up to and including approximately 18 ft.; on or about 1/23/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2015-02-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-17
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - Employees working directly under ongoing overhead construction activities were not using head protection; on or about 1/23/15. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.

Date of last update: 30 Mar 2025