Name: | SPLINTERS, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 13 Mar 2001 (24 years ago) |
Entity Number: | 2615385 |
ZIP code: | 11743 |
County: | Suffolk |
Place of Formation: | New York |
Principal Address: | 98 W 19TH STREET, HUNTINGTON STATION, NY, United States, 11746 |
Address: | PO BOX 2306, HALESITE, NY, United States, 11743 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | PO BOX 2306, HALESITE, NY, United States, 11743 |
Name | Role | Address |
---|---|---|
WILLIAM J WARK JR | Chief Executive Officer | PO BOX 2306, HALESITE, NY, United States, 11743 |
Start date | End date | Type | Value |
---|---|---|---|
2005-06-02 | 2009-03-31 | Address | 3 KNOLL COURT, HUNTINGTON, NY, 11743, USA (Type of address: Chief Executive Officer) |
2003-03-06 | 2005-06-02 | Address | 3 KNOLL COURT, HUNTINGTON, NY, 11743, USA (Type of address: Chief Executive Officer) |
2003-03-06 | 2009-03-31 | Address | 3 KNOLL COURT, HUNTINGTON, NY, 11743, USA (Type of address: Principal Executive Office) |
2001-03-13 | 2009-03-31 | Address | 3 KNOLL COURT, HUNTINGTON, NY, 11743, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
101015000022 | 2010-10-15 | ERRONEOUS ENTRY | 2010-10-15 |
DP-1872295 | 2010-07-28 | DISSOLUTION BY PROCLAMATION | 2010-07-28 |
090331003075 | 2009-03-31 | BIENNIAL STATEMENT | 2009-03-01 |
070402003053 | 2007-04-02 | BIENNIAL STATEMENT | 2007-03-01 |
050602002805 | 2005-06-02 | BIENNIAL STATEMENT | 2005-03-01 |
030306002011 | 2003-03-06 | BIENNIAL STATEMENT | 2003-03-01 |
010313000228 | 2001-03-13 | CERTIFICATE OF INCORPORATION | 2001-03-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339359671 | 0214700 | 2013-08-28 | 3374 OCEAN AVE., OCEANSIDE, NY, 11572 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2013-09-06 |
Abatement Due Date | 2013-09-12 |
Current Penalty | 1200.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-10-16 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) worksite - Employees working directly under ongoing roof work did not have head protection; on or about 08/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-09-06 |
Abatement Due Date | 2013-09-12 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) worksite - Employees removing shingles and tar paper from a 6-12 pitch roof, 14 feet 10 inches above the ground were not provided with fall protection; on or about 08/28/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2013-09-06 |
Abatement Due Date | 2013-09-25 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) worksite - Employees removing shingles and tar paper from a 6-12 pitch roof, 14 feet 10 inches above the ground were not provided with fall protection. The employees did not reconize the hazard of the falls and means to abate, the employees were not trained; on or about 08/28/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-09-06 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Worksite - Employees were using an unsecured ladder, with the side rails 10 inches above the upper landing to gain access to the roof; on or about 08/28/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2013-09-06 |
Abatement Due Date | 2013-09-25 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-16 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) worksite - Employees were using an unsecured ladder, with the side rails 10 inches above the upper landing to gain access to the roof. The employees did not recognize the hazard and means to abate the hazard, the employees were not trained; on or about 08/28/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1666493 | Intrastate Non-Hazmat | 2007-07-16 | - | - | 2 | 2 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 30 Mar 2025
Sources: New York Secretary of State