Search icon

HUOT WELDING SERVICE, INC.

Company Details

Name: HUOT WELDING SERVICE, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 10 Apr 2001 (24 years ago)
Entity Number: 2626491
ZIP code: 13634
County: Jefferson
Place of Formation: New York
Address: 17325 STAR SCHOOL HOUSE ROAD, DEXTER, NY, United States, 13634
Principal Address: 17325 STAR SCHOOL RD, DEXTER, NY, United States, 13634

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 17325 STAR SCHOOL HOUSE ROAD, DEXTER, NY, United States, 13634

Chief Executive Officer

Name Role Address
MICHAEL R HUOT Chief Executive Officer 17325 STAR SCHOOL RD, DEXTER, NY, United States, 13634

History

Start date End date Type Value
2023-04-07 2023-04-07 Address 17325 STAR SCHOOL RD, DEXTER, NY, 13634, USA (Type of address: Chief Executive Officer)
2003-04-14 2023-04-07 Address 17325 STAR SCHOOL RD, DEXTER, NY, 13634, USA (Type of address: Chief Executive Officer)
2001-04-10 2023-04-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2001-04-10 2023-04-07 Address 17325 STAR SCHOOL HOUSE ROAD, DEXTER, NY, 13634, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230407001957 2023-04-07 BIENNIAL STATEMENT 2023-04-01
211020000874 2021-10-20 BIENNIAL STATEMENT 2021-10-20
110607002317 2011-06-07 BIENNIAL STATEMENT 2011-04-01
090504002602 2009-05-04 BIENNIAL STATEMENT 2009-04-01
030414002167 2003-04-14 BIENNIAL STATEMENT 2003-04-01
010410000430 2001-04-10 CERTIFICATE OF INCORPORATION 2001-04-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
333298644 0215800 2012-03-30 RENT A ZONE, 101 PUBLIC SQUARE, WATERTOWN, NY, 13601
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-03-30
Emphasis L: FALL, N: CTARGET
Case Closed 2013-11-18

Related Activity

Type Inspection
Activity Nr 329884
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2012-04-23
Abatement Due Date 2012-03-30
Current Penalty 600.0
Initial Penalty 1800.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) East side of building, on or about 3-30-12: Employees were working above and below each other while erecting steel and not wearing head protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-04-23
Current Penalty 600.0
Initial Penalty 3600.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch: a) East side of building, on or about 3-30-12: Two employees were working on a scaffold platform that was not fully planked, exposing the employee to a fall hazard of 13 feet.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2012-04-23
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 8
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) East side of building, on or about 3-30-12: Two employees were working on a scaffold platform that did not have base plates under the scaffold legs.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-04-23
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-05-08
Final Order 2012-10-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) East side of building, on or about 3-30-12: Employees were accessing a scaffold system that did not have a safe means of access, exposing employees to a fall hazard of 13 feet.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2012-04-23
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2012-05-08
Final Order 2012-10-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) East side of building, on or about 3-30-12: Two employees were working on a scaffold platform without fall protection, exposing the employee to a fall hazard of 13 feet.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2012-04-23
Current Penalty 600.0
Initial Penalty 4200.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a) East side of building, on or about 3-30-12: One employee was working on a steel platform without fall protection, exposing the employees to a fall hazard of 17 feet 1 inch.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2012-04-23
Current Penalty 600.0
Initial Penalty 1800.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) East side of building, on or about 3-30-12: Employees were accessing an upper platform from a lower platform that had a change in elevation of 4 feet 9 inches without the use of a ladder.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2012-04-23
Current Penalty 600.0
Initial Penalty 1800.0
Contest Date 2012-05-08
Final Order 2012-09-17
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a) East side of building, on or about 3-30-12: Employees were accessing a fire escape platform using stairs that were not equipped with stair rails on the open/unprotected sides.

Date of last update: 30 Mar 2025

Sources: New York Secretary of State