OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339444762 0213600 2013-10-21 SOUTHGATE PLAZA 952 UNION ROAD, WEST SENECA, NY, 14224
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-10-24
Emphasis L: FALL, P: FALL
Case Closed 2016-02-24

Related Activity

Type Inspection
Activity Nr 944469
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 2400.0
Contest Date 2013-12-10
Final Order 2014-09-29
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) On or about 10/21/13, in front of the Dollar Tree store at the Southgate Plaza, 952 Union Rd., West Seneca, NY: Masonry type fabricated frame scaffolding, two sections high, was erected so that employees could apply plaster to the exterior front of the canopy. The platform in two seperate areas on the top level of the scaffolding consisted of three wooden 2x12 OSHA planks, leaving a gap of approx. 24 inches between the uprights of the 60 inch wide scaffold. One employee applying plaster, and another employee walking back & forth on the top level of the scaffold were exposed to a fall of approx. 13 ft. off the frontside (north side) of the scaffold platform because the scaffold was not fully planked between the uprights. b) On or about 10/21/13, in front of the Dollar Tree store at the Southgate Plaza, 952 Union Rd., West Seneca, NY: Masonry type fabricated frame scaffolding, two sections high, was erected so that employees could apply plaster to the exterior front of the canopy. The platform in two seperate areas on the lower level of the scaffolding consisted of one wooden 2x12 OSHA plank, leaving a gap of approx. 48 inches between the uprights of the 60 inch wide scaffold. One employee applying plaster while standing on that single plank was exposed to a fall of 6 ft. 8 in. off the frontside (north side) of the scaffold platform because the scaffold was not fully planked between the uprights. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 1600.0
Contest Date 2013-12-10
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about 10/21/13, in front of the Dollar Tree store at the Southgate Plaza, 952 Union Rd., West Seneca, NY: Masonry type fabricated frame scaffolding, two sections high, was erected so that employees could apply plaster to the exterior front of the canopy. Employees were exposed to a potential fall of up to 13 ft. while accessing the first & second levels of the scaffold by climbing the end frames of the scaffold. The end frames were not designed & constructed for use as ladder rungs. No ladder or other safe access was provided. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-11-26
Current Penalty 0.0
Initial Penalty 2400.0
Contest Date 2013-12-10
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about 10/21/13, in front of the Dollar Tree store at the Southgate Plaza, 952 Union Rd., West Seneca, NY: Masonry type fabricated frame scaffolding, two sections high, was erected so that employees could apply plaster to the exterior front of the canopy. Two seperate areas on the top level of the scaffolding lacked guardrails. One employee applying plaster, and another employee walking back & forth on the top level of the scaffold were exposed to a fall of approx. 13 ft. off the frontside (north side) of the scaffold platform because no guardrails or other fall protection system was installed to protect the employees. NO ABATEMENT CERTIFICATION REQUIRED